scholarly journals Improvement of Power Quality WECS using AI Based STATCOM

Author(s):  
P Ankineedu Prasad A Ayyappa Swamy and

The major concern in a growing power quality is harmonics distortion which is caused by the non-linear nature of the loads. This problem has drawn much attention from utilities, users and industries. To reduce the harmonic distortion for improving the power quality of the system a custom power devices has been proposed. A static compensator (STATCOM) is implemented at distribution level for overcoming several power quality problems. In this paper, new control technic i.e AI is proposed on shunt compensator to estimates the weight values of load currents. The control approach is based on the convergence of the load currents and property of the input signal. A working prototype of the STATCOM is implemented using three-phase VSC and AI control technique based PWM controller approach is developed in MATLAB/SIMULINK.

Author(s):  
B Praveen Kumar and V V L Durga Bhavani

The major concern in a growing power quality is harmonics distortion which is caused by the non-linear nature of the loads. This problem has drawn much attention from utilities, users and industries. To reduce the harmonic distortion for improving the power quality of the system a custom power devices has been proposed. A static compensator (STATCOM) is implemented at distribution level for overcoming several power quality problems. In this paper, new control technic i.e AI is proposed on shunt compensator to estimates the weight values of load currents. The control approach is based on the convergence of the load currents and property of the input signal. A working prototype of the STATCOM is implemented using three-phase VSC and AI control technique based PWM controller approach is developed in MATLAB/SIMULINK.


Inventions ◽  
2019 ◽  
Vol 4 (1) ◽  
pp. 18
Author(s):  
Muhammad Rasool ◽  
Muhammad Khan ◽  
Zahoor Ahmed ◽  
Muhammad Saeed

Recently, power quality improvement has gained a lot of attention due to the rapidly increasing use of power electronics equipment. Several control strategies for DC/AC Voltage Source Inverters (VSI) have been developed to obtain good quality output with low harmonic distortion. This paper proposes a robust control scheme to improve the power quality of a three-phase DC/AC VSI. The control scheme includes an outer voltage loop and an inner current loop, with both controllers designed by the standard H∞ robust control technique. The system with the proposed controller has a low total harmonic distortion (THD) and improved power quality of output voltage in the presence of linear and non-linear loads. The simulation is carried out in MATLAB/Simulink environment, and the results of the proposed control scheme are compared with the performance of dead-beat (DB) predictive control and conventional proportional integral (PI) control. It is observed from the results that the proposed control scheme outperforms other control schemes in terms of the THD level, having a better steady-state and transient performance.


2019 ◽  
Vol 8 (2S11) ◽  
pp. 2452-2458

This paper presents the cascade multilevel UPQC for sag and swell mitigation of a grid connected hybrid system. Power quality is the major problem facing by today’s power system. Due to the use of power electronic converters and devices the harmonics are injected into the grid that may result in grid failure. To mitigate these harmonics custom power devices are used. UPQC is the custom power devise that is used in this paper. The seven level cascade multilevel converter is used for both the series and shunt inverters of UPQC for better harmonic distortion. This system is connected to the PV+WIND hybrid system to provide effective utilization of the resources. The UPQC contains a DC link which controls the Sag and Swell, LG Fault and improves the power quality of the system. This system is simulated in MATLAB/SIMULINK


2019 ◽  
Vol 8 (2) ◽  
pp. 4950-4955

Article describes about the improvisation of power quality using Distribution static compensator and Unified power quality conditioner in microgrid. The control method used for the elimination of problems, is predictive control technique. Controller is added in the Microgrid system with three renewable sources. Filters are also added to the system to mitigate the harmonics. The two custom power devices are modeled with model predictive controller [MPC] and made to control separately the existing Microgrid system. The results are taken and compared in both Microgrid modes of operation. The output is documented using MATLAB/Simulink software. Comparison is shown differently and harmonics values are reduced.


2009 ◽  
Vol 62-64 ◽  
pp. 53-59 ◽  
Author(s):  
B.A. Adegboye

The paper explores power quality disturbances on a specified section of the distribution network of a Textile Industry in Kaduna State of Nigeria. The 33kV PHCN incoming to the industry is stepped down to 11kV by a 7.5MVA, 33/11kV three-phase transformer. This transformer supplies various 11/.415kV transformers present in the distribution network. Another 11kV PHCN incoming is used in event of any failure from the 33/11kV transformer. The paper focuses on Transformer No. 1, a 150kVA, 11/.415kV three-phase transformer operating at 0.9 power factor, located at printing and dying (P/D) building 1. Majority of the loads on it are inductive. Measurements were taken at the secondary terminal of this transformer by the use of the Harmonitor 3000 power analyzer, which generates the voltage and current waveforms, power factor, voltage and current total harmonic distortion and the apparent power of the red, yellow and blue phases of the transformer. Analyses of these data reveal the disturbances due to harmonics in the phases and neutral of the transformer. The effect of the harmonic current is seen as poor power factor of the transformer. Considering the observations and analyses of the power quality of the transformer 1 (P/D), the paper proposes some recommendations for improving the power quality of the distribution network under study.


2021 ◽  
Vol 13 (2) ◽  
pp. 505
Author(s):  
Sumaya Jahan ◽  
Shuvra Prokash Biswas ◽  
Md. Kamal Hosain ◽  
Md. Rabiul Islam ◽  
Safa Haq ◽  
...  

The use of different control techniques has become very popular for controlling the performance of grid-connected photovoltaic (PV) systems. Although the proportional-integral (PI) control technique is very popular, there are some difficulties such as less stability, slow dynamic response, low reference tracking capability, and lower output power quality in solar PV applications. In this paper, a robust, fast, and dynamic proportional-integral resonance controller with a harmonic and lead compensator (PIR + HC + LC) is proposed to control the current of a 15-level neutral-point-clamped (NPC) multilevel inverter. The proposed controlled is basically a proportional-integral resonance (PIR) controller with the feedback of a harmonic compensator and a lead compensator. The performance of the proposed controller is analyzed in a MATLAB/Simulink environment. The simulation result represents admirable performance in terms of stability, sudden load change response, fault handling capability, reference tracking capability, and total harmonic distortion (THD) than those of the existing controllers. The responses of the inverter and grid outlets under different conditions are also analyzed. The harmonic compensator decreases the lower order harmonics of grid voltage and current, and the lead compensator provides the phase lead. It is expected that the proposed controller is a dynamic aspirant in the grid-connected PV system.


2021 ◽  
Vol 2 (2) ◽  
pp. 29-35
Author(s):  
Dmitry A. Sorokin ◽  
◽  
Sergey I. Volskiy ◽  
Jaroslav Dragoun ◽  
◽  
...  

The paper suggests a control system of a three-phase power factor corrector. The study of the control system operation is carried out and the expressions for calculating the permissible values of error amplifier factors are obtained. The influence of the error amplifier parameters on phase current quality is investigated. The dependence of total harmonic distortion input current on a combination of error amplifier parameters is obtained at a given value of power factor. The conditions under which the total harmonic distortion input current has the minimum value are found out. This article is of interest to power electronics engineers, who are aimed at developing a three-phase power factor corrector.


Author(s):  
Liu Yang ◽  
Qinyue Tan ◽  
Di Xiong ◽  
Zhengguang Liu

The overrun of transient power quality index caused by the large-capacity electric arc furnace (EAF) has become a prominent problem affecting the safe and stable operation of the power system. (1) In this paper, the relationship between arc furnace volt-age and current is derived based on the different stages of arc combustion, and the random variation of chaotic phenomenon of the arc voltage are simulated. Established an EAF model suitable for the study of transient power quality problems. (2) Take 50t AC EAF as an example to analyze the reactive power impact and the influence on the point of common coupling (PCC) voltage caused by the three-phase short circuit of the electrode. The results show that the experimental results are consistent with the theoretical analysis, verifying the correctness and effectiveness of the model. (3) When the three-phase short-circuit occurs, the reactive power impact is nearly 6 times that of normal operation, the short-circuit current is 2.66 times that of normal operation, and the effective value of the PCC voltage has dropped by 40.37%, which provides a theoretical basis for real-time compensation of impulsive reactive power and improvement of the transient power quality of the EAF.


2021 ◽  
Vol 23 (07) ◽  
pp. 678-689
Author(s):  
Bilal Ahmad Ganie ◽  
◽  
Dr. (Mrs.) Lini Mathew ◽  

This study provides an adaptive control approach of VSC (voltage source converter) coupled with SPV (solar photovoltaic array), in a 3P3W (three-phase three-wire) system with three single-phase non-linear loads having Distributed Static Compensator (DSTATCOM) abilities using P and O (perturb & observe) methodology. The adaptive control technique converges quickly and has a low mean square error. For the correction of power factor and zero voltage regulation modes, the system is studied and simulated. The system’s great efficacy at high voltages is due to its one-stage structure. Grid current harmonics are significantly below the IEEE-519 norm. The suggested system is modeled and simulated with the available sim power system toolbox in MATLAB/Simulink, and the system’s behavior under different loads and environmental circumstances is confirmed.


2020 ◽  
Vol 39 (6) ◽  
pp. 8225-8235
Author(s):  
Bandla Pavan Babu ◽  
V Indragandhi

In an Electrical system, Power Quality (PQ) is becoming significant to all types of consumers. With the increase of power demand from end users, maintaining the quality of power within the limitations is a major problem. In this paper, harmonic analysis in a grid connected three phase induction motor is tested according to PQ international standards which are found in the International Electro technical Commission (IEC). These mentioned standards are maintained in the transmission line and fed to the induction motor through a regenerative grid simulator. With the results obtained, execution of this fuzzy control system can be investigated through the digital simulation, which is based on MATLAB-SIMULINK package. It provides human operands to constitute a knowledge base which is used for diagnosing power quality and capable of predicting abnormal operation in Industries.