scholarly journals Simultaneous spectrophotometric determination of drugs lacking peak maxima in their zero-order profiles by graphical or statistical representation of data

2018 ◽  
Vol 9 (3) ◽  
pp. 194-201
Author(s):  
Ragaa Magdy ◽  
Ahmed Hemdan ◽  
Nermine Victor Fares ◽  
Maha Farouk

Trandolapril has no sharp peak in its zero-order spectrum, therefore it is difficult to be measured by direct spectrophotometry. In this study, direct univariate spectrophotometric methods were developed and validated for determination of Trandolapril and Verapamil combination in pure and tablet dosage forms. The first method for measuring both Trandolapril and Verapamil is Absorbance Subtraction (AS), this method depends on the presence of iso-absorptive point in the zero-order curve at 217 nm. It has the advantage of measuring the concentration of both Trandolapril and Verapamil from unified regression equation at the iso-absorptive point. The second, third and fourth methods were applied on the first order spectra of the studied drugs. Second method is Derivative Subtraction (DS) for Trandolapril and Derivative subtraction followed by spectrum subtraction (DS-SS) for Verapamil. The third and fourth methods are constant value and concentration value methods. In the concentration value method, the concentration of the drugs is determined from the graphical representation without the use of regression equations. All the developed methods were validated as per International Conference on Harmonization guidelines and the results proved that the developed methods are simple, accurate, and selective. Moreover, a statistical comparison between the developed methods and a reference method was done. Also, One-way ANOVA statistical test was done between all the proposed spectrophoto-metric methods and results showed no significant differences.

2012 ◽  
Vol 9 (3) ◽  
pp. 1645-1654 ◽  
Author(s):  
K. Raghubabu ◽  
L. Shanti Swarup ◽  
B. Kalyanaramu ◽  
M. N. Rao ◽  
C. Ramdas

Two simple, sensitive and cost effective visible spectrophotometric methods (M1 and M2) have been developed for the determination of venlafaxine hydrochloride from bulk and tablet dosage forms. The method M1 is based on the formation of green colored coordination complex by the drug with cobalt thiocyanate which is quantitatively extractable into nitro benzene with an absorption maximum of 626.4 nm. The method M2 involves internal salt formation of aconitic anhydride, dehydration product of citric acid [CIA] with acetic anhydride [Ac2O] to form colored chromogen with an absorption maximum of 561.2 nm. The calibration graph is linear over the concentration range of 10-50 µg/mL and 8-24 µg/mL for method M1 and M2 respectively. The proposed methods are applied to commercial available tablets and the results are statistically compared with those obtained by the reference method and validated by recovery studies. The results are found satisfactory and reproducible. These methods are applied successfully for the estimation of the venlafaxine hydrochloride in the presence of other ingredients that are usually present in dosage forms.


2006 ◽  
Vol 3 (3) ◽  
pp. 142-145
Author(s):  
P. Ravi Kumar ◽  
P. Bhanu Prakash ◽  
M. Murali Krishna ◽  
M. Santha Yadav ◽  
C. Asha Deepthi

Domperidone is an antiemetic and pantoprazole is an antiulcer drug. Simple, precise, rapid and selective simultaneous equation and Q- analysis UV spectrophotometric methods have been developed for the simultaneous determination of domperidone and pantoprazole from combined tablet dosage forms. The methods involve solving of simultaneous equations and Q-value analysis based on measurement absorptivity at 216, 287 and 290 nm respectively. Linearity lies between 1-15 mcg/mL for domperidone and 0-50 mcg/mL for pantoprazole.


2019 ◽  
Vol 2019 ◽  
pp. 1-11
Author(s):  
Shilan A. Omer ◽  
Nabil A. Fakhre

In this study, three simple and accurate spectrophotometric methods for simultaneous determination of pyriproxyfen and chlorothalonil residues in cucumbers and cabbages grown in experimental greenhouse were studied. The first method was based on the zero-crossing technique measurement for first and second derivative spectrophotometry. The second method was based on the first derivative of the ratio spectra. However, the third method was based on mean centering of ratio spectra. These procedures lack any previous separation steps. The calibration curves for three spectrophotometric methods are linear in the concentration range of 1–30 μg·mL−1 and 0.5–7 μg·mL−1 for pyriproxyfen and chlorothalonil successively. The recoveries ranged from 82.12–97.40% for pyriproxyfen and 81.51–97.04% for chlorothalonil with relative standard deviations less than 4.95% and 5.45% in all instances for pyriproxyfen and chlorothalonil, respectively. The results obtained from the proposed methods were compared statistically by using one-way ANOVA, and the results revealed there were no significant differences between ratio spectra and mean centering methods with the zero-crossing technique. The proposed methods are successfully applied for the simultaneous estimation of the residue of both pesticides in cucumber and cabbage samples.


2018 ◽  
Vol 33 (2) ◽  
pp. 21
Author(s):  
Kanakapura Basavaiah ◽  
Okram Zenita Devi

Two sensitive spectrophotometric methods are described for the determination of simvastatin (SMT) in bulk drug and in tablets. The methods are based on the oxidation of SMT by a measured excess of cerium (IV) in acid medium followed by determination of unreacted oxidant by two different reaction schemes. In one procedure (method A), the residual cerium (IV) is reacted with a fixed concentration of ferroin and the increase in absorbance is measured at 510 nm. The second approach (method B) involves thereduction of the unreacted cerium (IV) with a fixed quantity of iron (II), and the resulting iron (III) is complexed with thiocyanate and the absorbance measured at 470 nm. In both methods, the amount of cerium (IV) reacted corresponds to SMT concentration. The experimental conditions for both methods were optimized. In method A, the absorbance is found to increase linearly with SMT concentration (r = 0.9995) whereas in method B, the same decreased (r = -0.9943). The systems obey Beer’s law for 0.6-7.5 and 0.5-5.0 μg mL-1 for method A and method B, respectively. The calculated molar absorptivity values are 2.7 X 104 and 1.06 X 105 Lmol-1 cm-1, respectively; and the corresponding sandel sensitivity values are 0.0153 and 0.0039μg cm-2, respectively. The limit of detection (LOD) and quantification (LOQ) are reported for both methods. Intra-day and inter-day precision, and accuracy of the methods were established as per the current ICH guidelines. The methods were successfully applied to the determination of SMT in tablets and the results were statistically compared with those of the reference method by applying the Student’s t-test and F-test. No interference was observed from the common excipients added to tablets. The accuracy and validity of the methods were further ascertained by performing recovery experiments via standard addition procedure.


Author(s):  
MONIR Z. SAAD ◽  
ATEF AMER ◽  
KHALED ELGENDY ◽  
BASEM ELGENDY

Objective: Two simple, sensitive and accurate spectrophotometric methods have been developed for the determination of sofosbuvir (SOF) and daclatasvir (DAC) in pure forms and pharmaceutical formulations. Methods: The proposed methods are based on the oxidation of SOF and DAC by a known excess of cerium(IV) ammonium nitrate in sulphuric acid medium followed by determination of unreacted cerium(IV) by adding a fixed amount of indigo carmine (IC) and alizarin red S (ARS) dyes followed by measuring the absorbance at 610 and 360 nm, respectively. The experimental conditions affecting the reaction were studied and optimized. Results: The beer’s law was obeyed in the concentration ranges of 0.2-3.0, 0.2-4.0 for SOF and 0.5-4.5 and 0.5-5.0 μg/ml for DAC using IC and ARS methods, respectively with a correlation coefficient ≥ 0.9991. The calculated molar absorptivity values are 2.354 × 104, 1.933 × 104 for SOF and 1.786 × 104 and 2.015 × 104 L/mol. cm for DAC using IC and ARS methods, respectively u. The limits of detection and quantification are also reported. Intra-day and inter-day precision and accuracy of the methods have been evaluated. Conclusion: The methods were successfully applied to the assay of SOF and DAC in tablets and the results were statistically compared with those of the reference method by applying Student’s t-test and F-test. No interference was observed from the common tablet excipients. The accuracy and reliability of the methods were further ascertained by performing recovery studies using the standard addition method.


Author(s):  
Zeinab Adel Nasr ◽  
Noha S. Said ◽  
Sawsan A. Abdel-Razeq

Aims: Two spectrophotometric methods were developed and validated for the determination of sofosbuvir in presence of its alkaline degradate. Study Design: Ratio difference and ratio derivative methods were assisted for determination of sofosbuvir in presence of its alkaline degradate, laboratory-prepared mixtures and in tablet dosage forms. Place and Duration of Study: Pharmaceutical Analytical Chemistry Department, Faculty of Pharmacy (Girls), Al - Azhar University, between December 2019 and January 2020. Methodology: Two analytical methods were achieved and validated for the quantitative determination of Sofosbuvir in presence of its alkaline degradate. The first method was ratio difference (RD) method, where the UV absorption spectra of different concentrations of sofosbuvir were divided by the spectrum of a certain concentration (15 µg mL-1) as a devisor of its alkaline degradate to get the ratio difference spectra. Afterwards, the peak amplitudes difference between 253.7 and 243.5 nm were measured. The second method was the ratio derivative (1DR) method, where the first derivative of the ratio spectra (1DR) was obtained and its amplitude was measured at 247 and 268 nm. Good linearity was obtained over the concentration range of 3-15 µg mL-1 for the proposed methods. The proposed procedures were adopted for the selective determination of intact Sofosbuvir in presence of up to 80% of its degradation product. Sofosbuvir was exposed to different conditions as alkaline, acidic and oxidative degradation. Results: The proposed methods were developed and validated with good linearity range of 3-15 µg mL-1 for both methods, and also with good accuracy and precision. And the obtained results were statistically compared to those obtained by the reported method. Conclusion: Sofosbuvir was successfully determined by the proposed ratio difference and ratio derivative methods in bulk powder, laboratory prepared mixtures and tablet dosage form with good accuracy and precision. The methods were validated according to ICH guidelines. The results obtained were compared with those of the reported method and were found to be in good agreement.


2009 ◽  
Vol 2009 ◽  
pp. 1-11 ◽  
Author(s):  
Ashraf M. Mahmoud

New rapid, sensitive, and accurate kinetic spectrophotometric methods were developed, for the first time, to determine omeprazole (OMZ) in its dosage forms. The methods were based on the formation of charge-transfer complexes with both iodine and 2,3-dichloro-5,6-dicyano-1,4-benzoquinone (DDQ). The variables that affected the reactions were carefully studied and optimized. The formed complexes and the site of interaction were examined by UV/VIS, IR, and1H-NMR techniques, and computational molecular modeling. Under optimum conditions, the stoichiometry of the reactions between OMZ and the acceptors was found to be 1 : 1. The order of the reactions and the specific rate constants were determined. The thermodynamics of the complexes were computed and the mechanism of the reactions was postulated. The initial rate and fixed time methods were utilized for the determination of OMZ concentrations. The linear ranges for the proposed methods were 0.10–3.00 and 0.50–25.00   with the lowest LOD of 0.03 and 0.14   for iodine and DDQ, respectively. Analytical performance of the methods was statistically validated; RSD was <1.25% for the precision and <1.95% for the accuracy. The proposed methods were successfully applied to the analysis of OMZ in its dosage forms; the recovery was 98.91–100.32%  0.94–1.84, and was found to be comparable with that of reference method.


2006 ◽  
Vol 3 (2) ◽  
pp. 78-82 ◽  
Author(s):  
K. Vanitha Prakash ◽  
Jangala Venkateswara Rao

Two new simple, sensitive, rapid and economical Spectrophotometric Methods (A and B) have been developed for the determination of Nelfinavir Mesylate in pharmaceutical bulk and tablet dosage form. The method A is based on the reaction of Nelfinavir with ferric chloride, potassium ferricyanide and hydrochloric acid to form a bluish green colored chromogen. The Method B is based on the formation of blood red colored chromogen with Ferric chloride and 1,10-phenanthroline. The absorbances of the chromogen were measured at their respective wavelength of maximum absorbance against the corresponding reagent blank. The proposed methods have been successfully applied to the analysis of the bulk drug and its tablet dosage form. The methods have been statistically evaluated and were found to be precise and accurate.


2015 ◽  
Vol 1 (6) ◽  
pp. 270
Author(s):  
Audumbar Digambar Mali ◽  
Ritesh Bathe ◽  
Manojkumar Patil ◽  
Ashpak Tamboli

Simple, fast and reliable spectrophotometric methods were developed for determination of Levocetirizine in bulk and pharmaceutical dosage forms. The solutions of standard and the sample were prepared in methanol. The quantitative determination of the drug was carried out using the zero order derivative values measured at 230 nm and the area under the curve method values measured at 227-234 nm (n=2). Calibration graphs constructed at their wavelengths of determination were linear in the concentration range of Levocetirizine using 5-25?g/ml (r=0.998 and r=0.999) for zero order and area under the curve spectrophotometric method. All the proposed methods have been extensively validated as per ICH guidelines. There was no significant difference between the performance of the proposed methods regarding the mean values and standard deviations. Developed spectrophotometric methods in this study are simple, accurate, precise and sensitive to assay of Levocetirizine in tablets.


Sign in / Sign up

Export Citation Format

Share Document