scholarly journals Theoretical Study for an Adsorption Refrigerator

2021 ◽  
Vol 8 (1) ◽  
Author(s):  
Abdulghani M. Ramadan

Adsorption cooling technology is one of the effective means to convert low grade thermal energy in to effective cooling, which improves energy efficiency and lowers environmental pollution. The main objective of this study is to investigate the thermal performance of an adsorption refrigerator theoretically. The working adsorbent/adsorbate pair used is Granular Activated Carbon, GAC/R134a pa*ir. The effect of different design parameters and operating conditions on the system performance is studied and interpreted.Some assumptions and approximations are also considered. A computer program is written using Matlab. Results show that the equilibrium adsorption capacity is highly affected by the driving temperature and equilibrium pressure. Increasing equilibrium pressure leads to a corresponding increase in the equilibrium adsorption capacity whereas it is value is decreased as the driving temperature increases. Moreover, increasing the driving and evaporator temperatures raise the values of the Specific Cooling Effect (SCE) andCoefficient of Performance (COP). The maximum values of SCE and COP are 60 KJ/kg and 0.4 corresponding to driving and evaporator temperatures of 100 oC and 20 oC respectively. However, increasing the condenser temperature leads to a remarked decrease in SCE and COP of the cooling system. SCE and COP values are 32 KJ/kg and 0.22 at driving and condenser temperatures of 100 oC and 40 oC respectively. When comparing the present study results with literature, there is a good agreement in general. It is clear that the adsorption cooling system can be driven effectively by low grade heat sources such as, solar energy, waste heat energy, geothermal energy…etc.

Author(s):  
Noman Yousuf ◽  
Timothy Anderson ◽  
Roy Nates

Abstract Despite being identified nearly a century ago, the diffusion absorption refrigeration (DAR) cycle has received relatively little attention. One of the strongest attractions of the DAR cycle lies in the fact that it is thermally driven and does not require high value work. This makes it a prime candidate for harnessing low grade heat from solar collectors, or the waste heat from stationary generators, to produce cooling. However, to realize the benefits of the DAR cycle, there is a need to develop an improved understanding of how design parameters influence its performance. In this vein, this work developed a new parametric model that can be used to examine the performance of the DAR cycle for a range of operating conditions. The results showed that the cycle's performance was particularly sensitive to several factors: the rate of heat added and the temperature of the generator, the effectiveness of the gas and solution heat exchangers, the mass flowrate of the refrigerant and the type of the working fluid. It was shown that can deliver good performance at low generator temperatures if the refrigerant mass fraction in the strong solution is made as high as possible. Moreover, it was shown that a H2O-LiBr working pair could be useful for achieving cooling at low generator temperatures.


Author(s):  
James F. Walton ◽  
Andrew Hunsberger ◽  
Hooshang Heshmat

In this paper the authors will present the design and preliminary test results for a distributed electric generating system that uses renewable energy source for economical load-following and peak-shaving capability in an oil-free, high-speed micro-turboalternator system using compliant foil bearings and a permanent magnet alternator. Test results achieved with the prototype system operating to full speed and under power generating mode will be presented. A comparison between predicted and measured electrical output will also be presented up to a power generating level of 25 kWe at approximately 55,000 rpm. The excellent correlation between design and test provides the basis for scale up to larger power levels. Based upon the turboalternator test results a thermodynamic cycle analysis of a system using low grade waste heat water at approximately 100 C will be reviewed. The tradeoff study results for a series of environmentally friendly refrigerant working fluids will also be presented including sensitivity to vaporization and condensing temperatures. Based on the cycle and pinch point analyses predicted maximum output power was determined. Finally a preliminary turbine design for the selected R134a working fluid was completed. The results of this study show that a net output power level of greater than 40 kW is possible for approximately 240 l/m flow of water at 100C is possible.


Author(s):  
M. Deligant ◽  
S. Braccio ◽  
T. Capurso ◽  
F. Fornarelli ◽  
M. Torresi ◽  
...  

Abstract The Organic Rankine Cycle (ORC) allows the conversion of low-grade heat sources into electricity. Although this technology is not new, the increase in energy demand and the need to reduce CO2 emissions create new opportunities to harvest low grade heat sources such as waste heat. Radial turbines have a simple construction, they are robust and they are not very sensitive to geometry inaccuracies. Most of the radial inflow turbines used for ORC application feature a vaned nozzle ensuring the appropriate distribution angle at the rotor inlet. In this work, no nozzle is considered but only the vaneless gap (distributor). This configuration, without any vaned nozzle, is supposed to be more flexible under varying operating conditions with respect to fixed vanes and to maintain a good efficiency at off-design. This paper presents a performance analysis carried out by means of two approaches: a combination of meanline loss models enhanced with real gas fluid properties and 3D CFD computations, taking into account the entire turbomachine including the scroll housing, the vaneless gap, the turbine wheel and the axial discharge pipe. A detailed analysis of the flow field through the turbomachine is carried out, both under design and off design conditions, with a particular focus on the entropy field in order to evaluate the loss distribution between the scroll housing, the vaneless gap and the turbine wheel.


2014 ◽  
Vol 1070-1072 ◽  
pp. 1679-1683
Author(s):  
Qin Ouyang ◽  
Guang Xiao Kou ◽  
Min Ouyang

According to the climate conditions of Hunan province and the design parameters related to air conditioning, the energy consumption and the related characteristics of the liquid desiccant evaporative cooling system (LDECS) are compared with primary return air conditioning system. The results show that energy consumption of LDECS can be decreased by 11.78% compared to the primary return air system. LDECS has a certain degree of energy saving potential in Hunan province, especially when waste heat is available.


2012 ◽  
Vol 550-553 ◽  
pp. 1561-1565 ◽  
Author(s):  
Tian Tian Xu ◽  
Chu Rui Huang ◽  
Yuan Yuan Luo ◽  
Qiang Du ◽  
Shi Lin Zhao

The new adsorption material was prepared by grafting the larch tannin onto aminated silica beads with the glutaraldehyde as the cross-linking agent. The adsorption properties of Pr3+and Nd3+on the new adsorbent material in aqueous solution were investigated. The results showed that the equilibrium adsorption capacities of this adsorbent to Pr3+, Nd3+were 402.12mg/g, 305.43mg/g at 303K when the initial concentrations of each ions were 442.7mg/L, 432.6mg/L, respectively and the pH value was 5.5; the maximum adsorption quantities of each ions were 576.34mg/g, 497.02mg/g at 303K when the initial concentrations of each ions were 704.5mg/L, 721.0mg/L, respectively and the pH value was 5.5. The effect of pH value was significant to the equilibrium adsorption capacity, the optimum pH values of this material to Pr3+and Nd3+were both 5.5; while the effect of the temperature was not obvious to the equilibrium adsorption capacity. The adsorption thermodynamics meet Freundlich equation, and the adsorption kinetics data of this adsorbent to Pr3+, Nd3+fitted with the pseudo-second-order rate equation dynamics model.


2021 ◽  
Vol 238 ◽  
pp. 10008
Author(s):  
Kirill Abrosimov ◽  
Federica Sciacchitano ◽  
Gianluca Pasini ◽  
Andrea Baccioli ◽  
Aldo Bischi ◽  
...  

Aiming for the better environmental and economic performance of traditional engines, waste heat recovery (WHR) technologies are actively studied to find their most beneficial applications. In this work, the inverted Brayton cycle (IBC) is investigated as a potential WHR solution for liquefied natural gas (LNG) fuelled transport truck. LNG being one of the less polluting fossil fuels is widely spreading nowadays in different industries due to the rapid development of the LNG supply chain in the world. LNG-fuelled cargo transportation follows this prevailing trend. Based on the overexpansion of flue gases to subatmospheric pressure, inverted Brayton cycle, in turn, is considered a prospective technology of WHR and techno-economic analysis of IBC in several configurations on-board of a heavy transport truck have been assessed. IBC is integrated into the engine cooling system in the basic layout, and additionally, it incorporates LNG regasification process in advanced configurations. Power balance based on Aspen Hysys model enables to perform system optimisation and gives preliminary design parameters of the system components. Cost function approach provides the basis for a preliminary economic assessment of the layouts. Although the system shows fuel economy of maximum about 2.1 %, analysis revealed the necessity to continue the search for better technical solutions in IBC-based systems to make them economically attractive due to high cost of installed equipment.


Energies ◽  
2021 ◽  
Vol 14 (18) ◽  
pp. 5663
Author(s):  
Luca Viscito ◽  
Gianluca Lillo ◽  
Giovanni Napoli ◽  
Alfonso William Mauro

In this paper, a seasonal performance analysis of a hybrid ejector cooling system is carried-out, by considering a multi-ejector pack as expansion device. A 20 kW ejector-based chiller was sized to obtain the optimal tradeoff between performance and investment costs. The seasonal performance of the proposed solution was then evaluated through a dynamic simulation able to obtain the performance of the designed chiller with variable ambient temperatures for three different reference climates. The optimized multi-ejector system required three or four ejectors for any reference climate and was able to enhance the system performance at partial load, with a significant increase (up to 107%) of the seasonal energy efficiency ratio. The proposed system was then compared to conventional cooling technologies supplied by electric energy (electrical chillers EHP) or low-grade heat sources (absorption chillers AHP) by considering the total costs for a lifetime of 20 years and electric energy-specific costs for domestic applications from 0.10 to 0.50 €/kWhel. The optimized multi-ejector cooling system presented a significant convenience with respect to both conventional technologies. For warmer climates and with high electricity costs, the minimum lifetime for the multi-ejector system to achieve the economic break-even point could be as low as 1.9 years.


Energies ◽  
2019 ◽  
Vol 12 (3) ◽  
pp. 501 ◽  
Author(s):  
Tilia Dahou ◽  
Patrick Dutournié ◽  
Lionel Limousy ◽  
Simona Bennici ◽  
Nicolas Perea

The aim of this paper is to improve the operating share of a biomass cogeneration unit by using unavoidable heat waste heat recovered from a district network heating used for drying woody biomass’ return water (law-grade temperature heat). The optimal operating conditions of a drying unit added to the system were estimated from an energy and a financial point of view, applying four objective functions (drying time, energy consumption, energy balance, and financial performance of the cogeneration unit). An experimental design methodology used heat for the implementation of these functions and to obtain an operating chart. Numerical modelling was performed to develop a simulation tool able to illustrate the unsteady operations able to take into account the available waste heat. Surprisingly, the model shows that the right strategy to increase the financial gain is to produce more warm water than necessary and to consequently dispose higher quantities of unavoidable heat in the network’s return water, which heat up the drying air at a higher temperature. This result contrasts with the current approaches of setting-up cogeneration units that are based on the minimization of the heat production.


2021 ◽  
pp. 1-29
Author(s):  
Ali Alsagri

Abstract The experience of leading countries in distributed energy systems (e.g., Scandinavian countries) shows that district cooling systems are highly beneficial techno-economic-environmentally by facilitating the use of waste heat resources, solar energy, etc., for cold supply at large scales. This study proposes the optimal development of a novel district cooling design utilizing the exhaust waste heat of an energy plant in a case study in Saudi Arabia. The optimal configuration of the hybrid system, the sizing of its components, and operating conditions of them are found using multiobjective optimization techniques based on the genetic algorithm method and a creative performance assessment index. Then, the feasibility of this optimized proposal is investigated through comprehensive thermodynamic and economic analyses. The results show that a district cooling system can surely cope with the harsh climate condition of the case study and provide the required interior comfort conditions. The energy and exergy efficiencies of the system can be as high as 62% and 53% using an absorption chiller utilizing a power plant's waste heat along with a storage tank for peak shaving. The levelized cost of cooling of the system can be 28 USD/MWh, by which the payback period will be only 8 years.


Author(s):  
Govinda Mahajan ◽  
Heejin Cho ◽  
Scott M. Thompson ◽  
Harrison Rupp ◽  
Kevin Muse

Oscillating heat pipes (OHPs) were experimentally assessed as a passive-type heat transfer device for air-to-air heat exchange in a typical Heating Ventilation & Air conditioning system (HVAC) with adjacent air streams at different temperatures. The objective is to utilize, otherwise wasted thermal energy to pre-heat or pre-cool air in order to reduce the payload on HVAC systems, thus reducing energy consumption. OHPs can achieve effective thermal conductivities on-the-order of 10,000 W/m-K via no internal wicking structure and hence can perform aforementioned heat transfer task while providing an aerodynamic form factor. A unique working fluid with limited research inside OHPs, but with properties desirable for low grade heat fluxes, i.e. n-pentane with 70 % fill ratio, was chosen as the working fluid to achieve maximum heat transfer. Aerodynamic performance, in terms of pressure drop, was evaluated and juxtaposed with heat transfer gain/loss. The OHP thermal performance and total heat transfer for hot-environment HVAC operation was benchmarked with an empty/evacuated OHP with same overall dimensions. Results indicate that the current, atypically-long OHP is fully-capable of operating in the air-to-air convection mode for waste heat recovery for typical HVAC operating conditions. Since the OHP is passive, cost effective, and relatively aerodynamic (no fins were used), the potential cost savings for its integration into HVAC systems can be significant.


Sign in / Sign up

Export Citation Format

Share Document