scholarly journals Intercomparison of midlatitude tropospheric and lower-stratospheric water vapor measurements and comparison to ECMWF humidity data

2018 ◽  
Vol 18 (22) ◽  
pp. 16729-16745 ◽  
Author(s):  
Stefan Kaufmann ◽  
Christiane Voigt ◽  
Romy Heller ◽  
Tina Jurkat-Witschas ◽  
Martina Krämer ◽  
...  

Abstract. Accurate measurement of water vapor in the climate-sensitive region near the tropopause is very challenging. Unexplained systematic discrepancies between measurements at low water vapor mixing ratios made by different instruments on airborne platforms have limited our ability to adequately address a number of relevant scientific questions on the humidity distribution, cloud formation and climate impact in that region. Therefore, during the past decade, the scientific community has undertaken substantial efforts to understand these discrepancies and improve the quality of water vapor measurements. This study presents a comprehensive intercomparison of airborne state-of-the-art in situ hygrometers deployed on board the DLR (German Aerospace Center) research aircraft HALO (High Altitude and LOng Range Research Aircraft) during the Midlatitude CIRRUS (ML-CIRRUS) campaign conducted in 2014 over central Europe. The instrument intercomparison shows that the hygrometer measurements agree within their combined accuracy (±10 % to 15 %, depending on the humidity regime); total mean values agree within 2.5 %. However, systematic differences on the order of 10 % and up to a maximum of 15 % are found for mixing ratios below 10 parts per million (ppm) H2O. A comparison of relative humidity within cirrus clouds does not indicate a systematic instrument bias in either water vapor or temperature measurements in the upper troposphere. Furthermore, in situ measurements are compared to model data from the European Centre for Medium-Range Weather Forecasts (ECMWF) which are interpolated along the ML-CIRRUS flight tracks. We find a mean agreement within ±10 % throughout the troposphere and a significant wet bias in the model on the order of 100 % to 150 % in the stratosphere close to the tropopause. Consistent with previous studies, this analysis indicates that the model deficit is mainly caused by too weak of a humidity gradient at the tropopause.

2018 ◽  
Author(s):  
Stefan Kaufmann ◽  
Christiane Voigt ◽  
Romy Heller ◽  
Tina Jurkat-Witschas ◽  
Martina Krämer ◽  
...  

Abstract. Accurate measurement of water vapor in the climate sensitive region near the tropopause turned out to be very challenging. Unexplained systematic discrepancies between measurements at low water vapor mixing ratios made by different instruments on airborne platforms have limited our ability to adequately address a number relevant scientific questions on the humidity distribution, cloud formation and climate impact in that region. Therefore, during the past decade, the scientific community has undertaken substantial efforts to understand these discrepancies and improve the quality of water vapor measurements. This study presents a comprehensive intercomparison of airborne state-of-the-art in situ hygrometers deployed onboard the DLR (German Aerospace Center) research aircraft HALO during the Mid-Latitude CIRRUS (ML-CIRRUS) campaign conducted in 2014 over central Europe. The instrument intercomparison shows that the hygrometer measurements agree within their combined accuracy (±10 to 15 %, depending on the humidity regime), total mean values even agree within 2.5 %. However, systematic differences on the order of 10 % and up to a maximum of 15 % are found for mixing ratios below 10 parts per million (ppm) H2O. A comparison of relative humidity within cirrus clouds does not indicate a systematic instrument bias in either water vapor or temperature measurements in the upper troposphere. Furthermore, in situ measurements are compared to model data from the European Centre for Medium-Range Weather Forecasts (ECMWF) which are interpolated along the ML-CIRRUS flight tracks. We find a mean agreement within ±10 % throughout the troposphere and a significant wet bias in the model on the order of 100 % to 150 % in the stratosphere close to the tropopause. Consistent with previous studies, this analysis indicates that the model deficit is mainly caused by a blurred humidity gradient at tropopause altitudes.


2010 ◽  
Vol 10 (18) ◽  
pp. 9039-9056 ◽  
Author(s):  
C. Voigt ◽  
U. Schumann ◽  
T. Jurkat ◽  
D. Schäuble ◽  
H. Schlager ◽  
...  

Abstract. Lineshaped contrails were detected with the research aircraft Falcon during the CONCERT – CONtrail and Cirrus ExpeRimenT – campaign in October/November 2008. The Falcon was equipped with a set of instruments to measure the particle size distribution, shape, extinction and chemical composition as well as trace gas mixing ratios of sulfur dioxide (SO2), reactive nitrogen and halogen species (NO, NOy, HNO3, HONO, HCl), ozone (O3) and carbon monoxide (CO). During 12 mission flights over Europe, numerous contrails, cirrus clouds and a volcanic aerosol layer were probed at altitudes between 8.5 and 11.6 km and at temperatures above 213 K. 22 contrails from 11 different aircraft were observed near and below ice saturation. The observed NO mixing ratios, ice crystal and soot number densities are compared to a process based contrail model. On 19 November 2008 the contrail from a CRJ-2 aircraft was penetrated in 10.1 km altitude at a temperature of 221 K. The contrail had mean ice crystal number densities of 125 cm−3 with effective radii reff of 2.6 μm. The presence of particles with r>50 μm in the less than 2 min old contrail suggests that natural cirrus crystals were entrained in the contrail. Mean HONO/NO (HONO/NOy) ratios of 0.037 (0.024) and the fuel sulfur conversion efficiency to H2SO4 (εS↓) of 2.9 % observed in the CRJ-2 contrail are in the range of previous measurements in the gaseous aircraft exhaust. On 31 October 2010 aviation NO emissions could have contributed by more than 40% to the regional scale NO levels in the mid-latitude lowest stratosphere. The CONCERT observations help to better quantify the climate impact from contrails and will be used to investigate the chemical processing of trace gases on contrails.


1974 ◽  
Vol 52 (8) ◽  
pp. 1527-1531 ◽  
Author(s):  
H. J. Mastenbrook

Nearly 10 years of water-vapor measurements to heights of 30 km provide a basis for assessing the natural concentration of stratospheric water vapor and its variability. The measurements which began in 1964 have been made at monthly intervals from the mid-latitude location of Washington, D.C, using a balloon-borne frost-point hygrometer. The observations show the mixing ratio of water-vapor mass to air mass in the stratosphere to be in the general range of 1 to 4 p.p.m. with a modal concentration between 2 and 3 p.p.m. An annual cycle of mixing ratio is evident for the low stratosphere. A trend of water-vapor increase observed during the first 6 years does not persist beyond 1969 or 1970. The 6 year increase was followed by a marked decrease in 1971, with mixing ratios remaining generally below 3 p.p.m. thereafter. The measurements of recent years suggest that the series of observations may have begun during a period of low water-vapor concentration in the stratosphere.


2011 ◽  
Vol 11 (16) ◽  
pp. 8433-8446 ◽  
Author(s):  
M. R. Schoeberl ◽  
A. E. Dessler

Abstract. Domain filling, forward trajectory calculations are used to examine the global dehydration processes that control stratospheric water vapor. As with most Lagrangian models of this type, water vapor is instantaneously removed from the parcel to keep the relative humidity (RH) with respect to ice from exceeding saturation or a specified super-saturation value. We also test a simple parameterization of stratospheric convective moistening through ice lofting and the effect of gravity waves as a mechanism that can augment dehydration. Comparing diabatic and kinematic trajectories driven by the MERRA reanalysis, we find that, unlike the results from Liu et al. (2010), the additional transport due to the vertical velocity "noise" in the kinematic calculation creates too dry a stratosphere and a too diffuse a water-vapor tape recorder signal compared observations. We also show that the kinematically driven parcels are more likely to encounter the coldest tropopause temperatures than the diabatic trajectories. The diabatic simulations produce stratospheric water vapor mixing ratios close to that observed by Aura's Microwave Limb Sounder and are consistent with the MERRA tropical tropopause temperature biases. Convective moistening, which will increase stratospheric HDO, also increases stratospheric water vapor while the addition of parameterized gravity waves does the opposite. We find that while the Tropical West Pacific is the dominant dehydration location, but dehydration over Tropical South America is also important. Antarctica makes a small contribution to the overall stratospheric water vapor budget as well by releasing very dry air into the Southern Hemisphere stratosphere following the break up of the winter vortex.


2020 ◽  
Author(s):  
Michał Gałkowski ◽  
Armin Jordan ◽  
Michael Rothe ◽  
Julia Marshall ◽  
Frank-Thomas Koch ◽  
...  

Abstract. The intensive measurement campaign CoMet 1.0 (Carbon dioxide and Methane mission) took place during May and June 2018, with a focus on greenhouse gases over Europe. CoMet 1.0 aimed at characterising the distribution of CH4 and CO2 over significant regional sources with the use of a fleet of research aircraft, as well as validating remote sensing measurements from state-of-the-art instrumentation installed on-board against a set of independent in-situ observations. Here we present the results of over 55 hours of accurate and precise in situ measurements of CO2, CH4 and CO mixing ratios made during CoMet 1.0 flights with a cavity ring-down spectrometer aboard the German research aircraft HALO, together with results from analyses of 96 discrete air samples collected aboard the same platform. A careful in-flight calibration strategy together with post-flight quality assessment made it possible to determine both the single measurement precision as well as biases against respective WMO scales. We compare the result of greenhouse gas observations against two of the available global modelling systems, namely Jena CarboScope and CAMS (Copernicus Atmosphere Monitoring Service). We find overall good agreement between the global models and the observed mixing ratios in the free-tropospheric range, characterised by very low bias values for the CAMS CH4 and the CarboScope CO2 products, with a mean free tropospheric offset of 0 (14) ppb and 0.8 (1.3) ppm respectively, with the quoted number giving the standard uncertainty in the final digits for the numerical value. Higher bias is observed for CAMS CO2 (equal to 3.7 (1.5) ppm), and for CO the model-observation mismatch is variable with height (with offset equal to −1.0 (8.8)). We also present laboratory analyses of air samples collected throughout the flights, which include information on the isotopic composition of CH_4, and we demonstrate the potential of simultaneously measuring δ13C-CH4 and δ2H-CH4 from air to determine the sources of enhanced methane signals using even a limited amount of discrete samples. Using flasks collected during two flights over the Upper Silesian Coal Basin (USCB, southern Poland), one of the strongest methane-emitting regions in the European Union, we were able to use the Miller-Tans approach to derive the isotopic signature of the measured source, with values of δ2H equal to −224.7 (6.6) permil and δ13C to −50.9 (1.1) permil, giving significantly lower d2H values compared to previous studies in the area.


2015 ◽  
Vol 8 (12) ◽  
pp. 13693-13727
Author(s):  
M. Ghysels ◽  
E. D. Riviere ◽  
S. Khaykin ◽  
C. Stoeffler ◽  
N. Amarouche ◽  
...  

Abstract. In this paper we compare water vapor mixing ratio measurements from two quasi-parallel flights of the Pico-SDLA H2O and FLASH-B hygrometers. The measurements were made on 10 February 2013 and 13 March 2012, respectively, in the tropics near Bauru, Sao Paulo St., Brazil during an intense convective period. Both flights were performed as part of a French scientific project, TRO-Pico, to study the impact of the deep-convection overshoot on the water budget. Only a few instruments that permit the frequent sounding of stratospheric water vapor can be flown within a small volume weather balloons. Technical difficulties preclude the accurate measurement of stratospheric water vapor with conventional in situ techniques. The instruments described here are simple and lightweight, which permits their low-cost deployment by non-specialists aboard a small weather balloon. We obtain mixing ratio retrievals which agree above the cold-point tropopause to within 1.9 and 0.5 % for the first and second flights, respectively. This level of agreement for measured stratospheric water mixing ratio is among the best ever reported in the literature. Because both instruments show similar profiles within their combined uncertainties, we conclude that the Pico-SDLA H2O and FLASH-B datasets are mutually consistent.


2020 ◽  
Author(s):  
Andrea Rau ◽  
Valentin Lauther ◽  
Johannes Wintel ◽  
Emil Gehardt ◽  
Peter Hoor ◽  
...  

<p>Over the course of the summer, when the subtropical jet is weakest, quasi-isentropic transport of young air from the troposphere and the tropical tropopause layer into the northern hemisphere (NH) lowermost stratosphere (LMS) is increased resulting in a drastic change of LMS chemical composition between spring and fall. The focus of this work is on the role of different transport paths into the NH LMS, including outflow from the Asian Monsoon, and their associated time scales of transport and mixing.<br><br>We present and analyse in situ measurements of CO<sub>2</sub> and various long-lived tracers obtained during three recent aircraft campaigns encompassing over 40 research flights in the NH UTLS during winter/spring, summer, and fall. The POLSTRACC/GW-LCYCLE/SALSA campaign probed the northern high latitude LMS in winter/spring 2016, deploying the German research aircraft HALO from Kiruna (Sweden) and from Germany. The second campaign deployed the M55 Geophysica research aircraft in July/August 2017 from Kathmandu, Nepal, in the frame of the EU-funded project StratoClim (Stratospheric and upper tropospheric processes for better Climate predications) in order to probe in situ for the first time the inside of the Asian Monsoon anticyclone. Roughly two months later the WISE (Wave-driven ISentropic Exchange) campaign deployed again HALO from Shannon (Ireland) in September and October 2017 to investigate isentropic transport and mixing in the NH LMS.<br><br>The University of Wuppertal measured CO<sub>2</sub> and a suite of long-lived tracers on each aircraft. On the Geophysica, the measurements were made with the HAGAR (High Altitude Gas AnalyzeR) instrument. On HALO, a recently developed extended 5-channel version, HAGAR-V, was flown, which in addition measured a suite of short-lived tracers by GC coupled with a mass spectrometer. The University of Mainz measured N2O and CO on HALO using laser absorption techniques. For our analysis we use mixing ratios of CO<sub>2</sub>, SF<sub>6</sub>, CFC-11, CFC-12, and N<sub>2</sub>O.<br><br>Owing to their different lifetimes, tropospheric growth (for SF<sub>6</sub>) and a seasonal cycle (for CO<sub>2</sub>), the LMS distributions of these long-lived trace gases and their development between spring and fall contain key information about the origin and mean stratospheric age of LMS air as well as time scales of rapid isentropic transport and mixing. The analysis of tracer measurements is complemented by simulations with the Chemical Lagrangian Model of the Stratosphere (CLaMS) providing information on age of air spectra and fractions of origin from specific surface regions, allowing in particular to assess the role of the Asian Monsoon in determining the composition of the NH LMS in fall.</p>


2008 ◽  
Vol 8 (17) ◽  
pp. 5245-5261 ◽  
Author(s):  
C. Kiemle ◽  
M. Wirth ◽  
A. Fix ◽  
G. Ehret ◽  
U. Schumann ◽  
...  

Abstract. In the tropics, deep convection is the major source of uncertainty in water vapor transport to the upper troposphere and into the stratosphere. Although accurate measurements in this region would be of first order importance to better understand the processes that govern stratospheric water vapor concentrations and trends in the context of a changing climate, they are sparse because of instrumental shortcomings and observational challenges. Therefore, the Falcon research aircraft of the Deutsches Zentrum für Luft- und Raumfahrt (DLR) flew a zenith-viewing water vapor differential absorption lidar (DIAL) during the Tropical Convection, Cirrus and Nitrogen Oxides Experiment (TROCCINOX) in 2004 and 2005 in Brazil. The measurements were performed alternatively on three water vapor absorption lines of different strength around 940 nm. These are the first aircraft DIAL measurements in the tropical upper troposphere and in the mid-latitudes lower stratosphere. Sensitivity analyses reveal an accuracy of 5% between altitudes of 8 and 16 km. This is confirmed by intercomparisons with the Fast In-situ Stratospheric Hygrometer (FISH) and the Fluorescent Advanced Stratospheric Hygrometer (FLASH) onboard the Russian M-55 Geophysica research aircraft during five coordinated flights. The average relative differences between FISH and DIAL amount to −3%±8% and between FLASH and DIAL to −8%±14%, negative meaning DIAL is more humid. The average distance between the probed air masses was 129 km. The DIAL is found to have no altitude- or latitude-dependent bias. A comparison with the balloon ascent of a laser absorption spectrometer gives an average difference of 0%±19% at a distance of 75 km. Six tropical DIAL under-flights of the Michelson Interferometer for Passive Atmospheric Sounding (MIPAS) on board ENVISAT reveal a mean difference of −8%±49% at an average distance of 315 km. While the comparison with MIPAS is somewhat less significant due to poorer comparison conditions, the agreement with the in-situ hygrometers provides evidence of the excellent quality of FISH, FLASH and DIAL. Most DIAL profiles exhibit a smooth exponential decrease of water vapor mixing ratio in the tropical upper troposphere to lower stratosphere transition. The hygropause with a minimum mixing ratio of 2.5 µmol/mol is found between 15 and 17 km. A high-resolution (2 km horizontal, 0.2 km vertical) DIAL cross section through the anvil outflow of tropical convection shows that the ambient humidity is increased by a factor of three across 100 km.


2015 ◽  
Vol 15 (14) ◽  
pp. 8521-8538 ◽  
Author(s):  
J. Meyer ◽  
C. Rolf ◽  
C. Schiller ◽  
S. Rohs ◽  
N. Spelten ◽  
...  

Abstract. For almost two decades, the airborne Fast In-situ Stratospheric Hygrometer (FISH) has stood for accurate and precise measurements of total water mixing ratios (WMR, gas phase + evaporated ice) in the upper troposphere and lower stratosphere (UT/LS). Here, we present a comprehensive review of the measurement technique (Lyman-α photofragment fluorescence), calibration procedure, accuracy and reliability of FISH. Crucial for FISH measurement quality is the regular calibration to a water vapor reference, namely the commercial frost-point hygrometer DP30. In the frame of this work this frost-point hygrometer is compared to German and British traceable metrological water standards and its accuracy is found to be 2–4 %. Overall, in the range from 4 to 1000 ppmv, the total accuracy of FISH was found to be 6–8 %, as stated in previous publications. For lower mixing ratios down to 1 ppmv, the uncertainty reaches a lower limit of 0.3 ppmv. For specific, non-atmospheric conditions, as set in experiments at the AIDA chamber – namely mixing ratios below 10 and above 100 ppmv in combination with high- and low-pressure conditions – the need to apply a modified FISH calibration evaluation has been identified. The new evaluation improves the agreement of FISH with other hygrometers to ± 10 % accuracy in the respective mixing ratio ranges. Furthermore, a quality check procedure for high total water measurements in cirrus clouds at high pressures (400–500 hPa) is introduced. The performance of FISH in the field is assessed by reviewing intercomparisons of FISH water vapor data with other in situ and remote sensing hygrometers over the last two decades. We find that the agreement of FISH with the other hygrometers has improved over that time span from overall up to ± 30 % or more to about ± 5–20 % @ < 10 ppmv and to ± 0–15 % @ > 10 ppmv. As presented here, the robust and continuous calibration and operation procedures of the FISH instrument over the last two decades establish the position of FISH as one of the core instruments for in situ observations of water vapor in the UT/LS.


Sign in / Sign up

Export Citation Format

Share Document