scholarly journals A performance assessment of the World Wide Lightning Location Network (WWLLN) via comparison with the Canadian Lightning Detection Network (CLDN)

2010 ◽  
Vol 3 (2) ◽  
pp. 1861-1887 ◽  
Author(s):  
D. Abreu ◽  
D. Chandan ◽  
R. H. Holzworth ◽  
K. Strong

Abstract. The World Wide Lightning Location Network (WWLLN) uses globally-distributed Very Low Frequency (VLF) receivers in order to observe lightning around the globe. Its objective is to locate as many global strokes as possible, with high temporal and spatial (<10 km) accuracy. Since detection is done in the VLF range, signals from high peak current lightning strokes are able to propagate up to ~104 km before being detected by the WWLLN sensors, allowing for receiving stations to be sparsely spaced. Through a comparison with measurements made by the Canadian Lightning Detection Network (CLDN) between May and August 2008 over a 4° latitude by 4° longitude region centered on Toronto, Canada, this study found that WWLLN detection was most sensitive to high peak current lightning strokes. Events were considered shared between the two networks if they fell within 0.5 ms of each other. Using this criterion, 19 128 WWLLN strokes (analyzed using the Stroke_B algorithm) were shared with CLDN lightning strokes, producing a detection efficiency of 2.8%. The peak current threshold for WWLLN detection is found to be ~20 kA, with the detection efficiency increasing to ~70% at peak currents of ±120 kA. The detection efficiency is seen to have a clear diurnal dependence, with a higher detection efficiency at local midnight than at local noon; this is attributed to the difference in the thickness of the ionospheric D-region between night and day. The mean time difference (WWLLN – CLDN) between shared events was −6.44 μs with a standard deviation of 35 μs, and the mean absolute location accuracy was 7.24 km with a standard deviation of 6.34 km. These results are generally consistent with previous comparison studies of the WWLLN with other regional networks around the world. Additional receiver stations are continuously being added to the network, acting to improve this detection efficiency.

2010 ◽  
Vol 3 (4) ◽  
pp. 1143-1153 ◽  
Author(s):  
D. Abreu ◽  
D. Chandan ◽  
R. H. Holzworth ◽  
K. Strong

Abstract. The World Wide Lightning Location Network (WWLLN) uses globally-distributed Very Low Frequency (VLF) receivers in order to observe lightning around the globe. Its objective is to locate as many global lightning strokes as possible, with high temporal and spatial (< 10 km) accuracy. Since detection is done in the VLF range, signals from high peak current lightning strokes are able to propagate up to ~104 km before being detected by the WWLLN sensors, allowing for receiving stations to be sparsely spaced. Through a comparison with measurements made by the Canadian Lightning Detection Network (CLDN) between May and August 2008 over a 4° latitude by 4° longitude region centered on Toronto, Canada, this study found that WWLLN detection was most sensitive to high peak current lightning strokes. Events were considered shared between the two networks if they fell within 0.5 ms of each other. Using this criterion, 19 128 WWLLN strokes (analyzed using the Stroke_B algorithm) were shared with CLDN lightning strokes, producing a detection efficiency of 2.8%. The peak current threshold for WWLLN detection is found to be ~20 kA, with its detection efficiency increasing from 11.3% for peak currents greater than 20 kA to 75.8% for peak currents greater than 120 kA. The detection efficiency is seen to have a clear diurnal dependence, with a higher detection efficiency at local midnight than at local noon; this is attributed to the difference in the thickness of the ionospheric D-region between night and day. The mean time difference (WWLLN − CLDN) between shared events was −6.44 μs with a standard deviation of 35 μs, and the mean absolute location accuracy was 7.24 km with a standard deviation of 6.34 km. These results are generally consistent with previous comparison studies of the WWLLN with other regional networks around the world. Additional receiver stations are continuously being added to the network, acting to improve this detection efficiency.


2006 ◽  
Vol 24 (12) ◽  
pp. 3197-3214 ◽  
Author(s):  
C. J. Rodger ◽  
S. Werner ◽  
J. B. Brundell ◽  
E. H. Lay ◽  
N. R. Thomson ◽  
...  

Abstract. An experimental Very Low Frequency (VLF) World-Wide Lightning Location Network (WWLLN) has been developed through collaborations with research institutions across the world, providing global real-time locations of lightning discharges. As of April 2006, the network included 25 stations providing coverage for much of the Earth. In this paper we examine the detection efficiency of the WWLLN by comparing the locations from this network with lightning location data purchased from a commercial lightning location network operating in New Zealand. Our analysis confirms that WWLLN favours high peak current return stroke lightning discharges, and that discharges with larger currents are observed by more stations across the global network. We then construct a first principles detection efficiency model to describe the WWLLN, combining calibration information for each station with theoretical modelling to describe the expected amplitudes of the VLF sferics observed by the network. This detection efficiency model allows the prediction of the global variation in WWLLN lightning detection, and an estimate of the minimum CG return stroke peak current required to trigger the network. There are strong spatial variations across the globe, primarily due to station density and sensitivity. The WWLLN is currently best suited to study the occurrence and impacts of high peak-current lightning. For example, in 2005 about 12% of the global elve-producing lightning will have been located by the network. Since the lightning-EMP which produce elves has a high mean rate (210 per minute) it has the potential to significantly influence the ionosphere on regional scales.


Atmosphere ◽  
2021 ◽  
Vol 12 (11) ◽  
pp. 1539
Author(s):  
Kai Kwong Hon ◽  
Pak Wai Chan

The Doppler Lidar windshear alerting system at the Hong Kong International Airport (HKIA), the first of its kind in the world, has been in operation since 2006. This paper reports on an enhancement to the automatic windshear detection algorithm at HKIA, which aims at filtering out alerts associated with smoother headwind changes spread over longer distances along the aircraft glide path (called “gentle ramps”) which may nonetheless exceed the well-established alerting threshold. Real-time statistics are examined over a 46-month study period between March 2016 and December 2019, covering a total of 2,017,440 min and over 1500 quality-controlled pilot reports of windshear (PIREP). The “gentle ramp removal” (GRR) function is able to effectively cut down the alert duration over the 5 major runway corridors, inclusive of both landing and take-off, which together account for over 98% of the PIREP received at HKIA during the study period. In all 5 runway corridors this is achieved with a proportionately smaller decrease—even with no changes in 2 cases—in the hit rate, highlighting the efficiency of the GRR function. The difference in statistical behaviour across the runway corridors also echo literature findings about the differences in length scale of wind disturbances at different locations within HKIA. This study serves as a unique documentation of the state-of-the-art in operational Lidar windshear detection and can provide useful reference to airports and aviation meteorologists around the world.


Author(s):  
Kohila Kalimuthu ◽  
Vanusha Avudaithangam

Background: Moderate anaemia seen in about 15-20% of pregnant women. Iron sucrose complex which is used intravenously for the correction of Iron deficiency anaemia. The drug has been able to raise the haemoglobin to satisfactory level when used in moderately anaemic iron deficient pregnant women. The objective of this study was to study the improvement of Hb% after treatment with intravenous Iron sucrose complex in moderately anaemic pregnant women belonging to 24-32 weeks of gestational age.Methods: 50 antenatal patients between gestational age 24-32 weeks with hemoglobin between 8-9.5g/dl were selected and included in this study. They were subjected to blood hemoglobin estimation, hematocrit and peripheral smear study. In each infusion, the maximum total dose administered was 200 mg iron sucrose in 100 ml of normal saline, slow IV infused over 30 minutes. Monitoring was done throughout the infusion to observe for any side effects.Results: Mean hemoglobin among the 50 patients before starting the therapy was 8.172g/dl and the mean hemoglobin at the end of one month of completing the therapy was 11.066g/dl. The rise in mean hemoglobin i.e. the difference in the mean hemoglobin before and after treatment was 2.894g/dl. The p value is 0.0001 which is statistically significant. The mean hematocrit of the 50 patients studied before starting the treatment was 26.772% with a standard deviation of 1.914. The mean hematocrit after completing the therapy was 33.872% with a standard deviation of 1.321. The difference in the mean hematocrit was 7.100% with a p value of 0.0001 which is statistically significant.Conclusions: Intravenous iron sucrose complex is well tolerated and highly efficacious in improving hemoglobin, hematocrit in the treatment of iron deficiency anaemia in antenatal women.


2021 ◽  
Vol 5 (1) ◽  
pp. 601-607
Author(s):  
A. U. Uduma ◽  
Joseph Akumah Ojogba ◽  
O. E. Okafor

In Katsina metropolitan, a variety of poultry feeds are available, and the quality and standards of these feeds are critical for the production of eggs and meat. As a result, the quality of selected chicken feeds sold in Katsina metropolitan was assessed by performing proximate analysis using AOAC methodology. Super starter, grower concentrate, broiler finisher, broiler starter, broiler super starter, layer mesh, grower mesh, and layer concentrate were among the samples used. The percentage mean to standard deviation was used to express the findings. The crude protein content of the diets studied ranged from 0.46 ± 0.00 percent to, 8.24± 0.02 percent, ash content 6.31± 0.01 percent – 33.30± 0.04 percent, crude fiber content 1.03 ±0.00 percent – 3.21± 0.00 percent, lipid content 0.11± 0.00 percent, 2.30 ±0.00 percent, moisture content 4.28 ±0.25 – 6.66 ±0.78 percent, and carbohydrate content 51.78± 2.68 – 83.72 ±0.57 percent. Although there was variation in the mean and standard deviation levels among the samples analyzed, such variations were not statistically significant (P>0.05) according to a one-way analysis of variance (ANOVA) for the difference in the mean levels of parameters evaluated in eight samples


2018 ◽  
Vol 11 (7) ◽  
pp. 4059-4072 ◽  
Author(s):  
Sergio Fabián León-Luis ◽  
Alberto Redondas ◽  
Virgilio Carreño ◽  
Javier López-Solano ◽  
Alberto Berjón ◽  
...  

Abstract. Total ozone column measurements can be made using Brewer spectrophotometers, which are calibrated periodically in intercomparison campaigns with respect to a reference instrument. In 2003, the Regional Brewer Calibration Centre for Europe (RBCC-E) was established at the Izaña Atmospheric Research Center (Canary Islands, Spain), and since 2011 the RBCC-E has transferred its calibration based on the Langley method using travelling standard(s) that are wholly and independently calibrated at Izaña. This work is focused on reporting the consistency of the measurements of the RBCC-E triad (Brewer instruments #157, #183 and #185) made at the Izaña Atmospheric Observatory during the period 2005–2016. In order to study the long-term precision of the RBCC-E triad, it must be taken into account that each Brewer takes a large number of measurements every day and, hence, it becomes necessary to calculate a representative value of all of them. This value was calculated from two different methods previously used to study the long-term behaviour of the world reference triad (Toronto triad) and Arosa triad. Applying their procedures to the data from the RBCC-E triad allows the comparison of the three instruments. In daily averages, applying the procedure used for the world reference triad, the RBCC-E triad presents a relative standard deviation equal to σ = 0.41 %, which is calculated as the mean of the individual values for each Brewer (σ157 = 0.362 %, σ183 = 0.453 % and σ185 = 0.428 %). Alternatively, using the procedure used to analyse the Arosa triad, the RBCC-E presents a relative standard deviation of about σ = 0.5 %. In monthly averages, the method used for the data from the world reference triad gives a relative standard deviation mean equal to σ = 0.3 % (σ157 = 0.33 %, σ183 = 0.34 % and σ185 = 0.23 %). However, the procedure of the Arosa triad gives monthly values of σ = 0.5 %. In this work, two ozone data sets are analysed: the first includes all the ozone measurements available, while the second only includes the simultaneous measurements of all three instruments. Furthermore, this paper also describes the Langley method used to determine the extraterrestrial constant (ETC) for the RBCC-E triad, the necessary first step toward accurate ozone calculation. Finally, the short-term or intraday consistency is also studied to identify the effect of the solar zenith angle on the precision of the RBCC-E triad.


2009 ◽  
Vol 26 (11) ◽  
pp. 2392-2402 ◽  
Author(s):  
Christina A. Stall ◽  
Kenneth L. Cummins ◽  
E. Philip Krider ◽  
John A. Cramer

Abstract Video recordings of cloud-to-ground (CG) lightning flashes have been analyzed in conjunction with correlated stroke reports from the U.S. National Lightning Detection Network (NLDN) to determine whether the NLDN is capable of identifying the different ground contacts in CG flashes. For 39 negative CG flashes that were recorded on video near Tucson, Arizona, the NLDN-based horizontal distances between the first stroke and the 62 subsequent strokes remaining in a preexisting channel had a mean and standard deviation of 0.9 ± 0.8 km and a median of 0.7 km. The horizontal distances between the first stroke and the 59 new ground contacts (NGCs) had a mean and standard deviation of 2.3 ± 1.7 km and a median of 2.1 km. These results are in good agreement with prior measurements of the random errors in NLDN positions in southern Arizona as well as video- and thunder-based measurements of the distances between all ground contacts in Florida. In cases where the distances between ground contacts are small and obscured by random errors in the NLDN locations, measurements of the stroke rise time, estimated peak current, and stroke order can be utilized to enhance the ability of the NLDN to identify strokes that produce new ground terminations.


Radio Science ◽  
2012 ◽  
Vol 47 (6) ◽  
pp. n/a-n/a ◽  
Author(s):  
M. L. Hutchins ◽  
R. H. Holzworth ◽  
J. B. Brundell ◽  
C. J. Rodger

2017 ◽  
Vol 6 (1) ◽  
pp. 199-207 ◽  
Author(s):  
Stephen A. Drake ◽  
John S. Selker ◽  
Chad W. Higgins

Abstract. Intrinsic permeability is an important parameter that regulates air exchange through porous media such as snow. Standard methods of measuring snow permeability are inconvenient to perform outdoors, are fraught with sampling errors, and require specialized equipment, while bringing intact samples back to the laboratory is also challenging. To address these issues, we designed, built, and tested a low-cost acoustic permeameter that allows computation of volume-averaged intrinsic permeability for a homogenous medium. In this paper, we validate acoustically derived permeability of homogenous, reticulated foam samples by comparison with results derived using a standard flow-through permeameter. Acoustic permeameter elements were designed for use in snow, but the measurement methods are not snow-specific. The electronic components – consisting of a signal generator, amplifier, speaker, microphone, and oscilloscope – are inexpensive and easily obtainable. The system is suitable for outdoor use when it is not precipitating, but the electrical components require protection from the elements in inclement weather. The permeameter can be operated with a microphone either internally mounted or buried a known depth in the medium. The calibration method depends on choice of microphone positioning. For an externally located microphone, calibration was based on a low-frequency approximation applied at 500 Hz that provided an estimate of both intrinsic permeability and tortuosity. The low-frequency approximation that we used is valid up to 2 kHz, but we chose 500 Hz because data reproducibility was maximized at this frequency. For an internally mounted microphone, calibration was based on attenuation at 50 Hz and returned only intrinsic permeability. We found that 50 Hz corresponded to a wavelength that minimized resonance frequencies in the acoustic tube and was also within the response limitations of the microphone. We used reticulated foam of known permeability (ranging from 2 × 10−7 to 3 × 10−9 m2) and estimated tortuosity of 1.05 to validate both methods. For the externally mounted microphone the mean normalized standard deviation was 6 % for permeability and 2 % for tortuosity. The mean relative error from known measurements was 17 % for permeability and 2 % for tortuosity. For the internally mounted microphone the mean normalized standard deviation for permeability was 10 % and the relative error was also 10 %. Permeability determination for an externally mounted microphone is less sensitive to environmental noise than is the internally mounted microphone and is therefore the recommended method. The approximation using the internally mounted microphone was developed as an alternative for circumstances in which placing the microphone in the medium was not feasible. Environmental noise degrades precision of both methods and is recognizable as increased scatter for replicate data points.


Sign in / Sign up

Export Citation Format

Share Document