Variable Shear Rate Viscosity of SBR-Filler-Plasticizer Systems

1974 ◽  
Vol 47 (4) ◽  
pp. 825-836 ◽  
Author(s):  
G. C. Derringer

Abstract Variable shear rate viscosity studies of compositions with variable filler and plasticizer levels have led to the development of a unifying viscosity model. Application of the model indicated that the fillers studied are less effective as stiffeners at shear rates typical of factory processing operations than at the low shear rates characteristic of the Mooney viscosity test. Thus, for proper comparative evaluations of pigment effect on processing, Mooney measurements are inadequate. The effect of shear rate on plasticizer efficiency will require more work to make definitive statements. Plasticizer evaluations appear to be a fruitful avenue for further exploration. The model developed has proved useful in understanding the individual contribution to the viscosity of the compound by the raw elastomer, the filler, and the plasticizer over a wide range of shear rates. The availability of this model will also result in an economy of experimentation as each shear rate of interest need not be studied separately. Having a valid model makes it possible to optimize the experimental design with regard to cost and information.

2021 ◽  
Vol 15 (3) ◽  
pp. 181-190
Author(s):  
Elif H Ozcan Cetin ◽  
Mehmet S Cetin ◽  
Mustafa B Ozbay ◽  
Hasan C Könte ◽  
Nezaket M Yaman ◽  
...  

Aim: We aimed to assess the association of whole blood with thromboembolic milieu in significant mitral stenosis patients. Methodology & results: We included 122 patients and classified patients into two groups as having thrombogenic milieu, thrombogenic milieu (+), otherwise patients without thrombogenic milieu, thrombogenic milieu (-). Whole blood viscosity (WBV) in both shear rates were higher in thrombogenic milieu (+) group comparing with thrombogenic milieu (-). WBV at high shear rate and WBV at low shear rate parameters were moderately correlated with grade of spontaneous echo contrast. Adjusted with other parameters, WBV parameters at both shear rates were associated with presence of thrombogenic milieu. Discussion & conclusion: We found that extrapolated WBV at both shear rates was significantly associated with the thrombogenic milieu in mitral stenosis. This easily available parameter may provide additional perspective about thrombogenic diathesis.


1976 ◽  
Vol 55 (3) ◽  
pp. 353-356 ◽  
Author(s):  
M. Braden ◽  
Ratna Perera

Six commercial fluoride gels have been studied, using a cone and plate viscometer. Also, the thickening agents have been analyzed using infrared spectroscopy. All gels showed stress thinning, which is the decrease of viscosity with shear rate. Such shear rate dependence is clinically convenient in that the gel will flow readily at the high shear stresses present when the gel is applied but will not flow readily under its own weight when on the tooth. Five materials containing hydroxyalkyl celluloses showed similar degrees of shear thinning. One material with a non-cellulosic thickener showed much more extreme stress thinning together with elastic behavior at low shear rates; such behavior may be clinically advantageous. All of the gels showed only slight temperature dependence of rheological properties.


1992 ◽  
Vol 289 ◽  
Author(s):  
John R. Melrose

AbstractAn overview is given of theories of aggregates under flow. These generally assume some sort of structural breakdown as the shear rate is increased. Models vary with both the rigidity of the bonding and the level of treatment of hydrodynamics. Results are presented for simulations of a Rouse model of non-rigid, (i.e. central force) weakly bonded aggregates. In large scale simulations different structures are observed at low and high shear rates. The change from one structure to another is associated with a change in the rate of shear thinning. The model captures low shear rate features of real systems absent in previous models: this feature is ascribed to agglomerate deformations. Quantitatively, the model is two orders of magnitude out from experiment but some scaling is possible.


Soft Matter ◽  
2014 ◽  
Vol 10 (47) ◽  
pp. 9470-9485 ◽  
Author(s):  
Howon Jin ◽  
Kyongok Kang ◽  
Kyung Hyun Ahn ◽  
Jan K. G. Dhont

A microscopic theory explains the origin of mass fluxes induced by spatial gradients in the shear rate, and leads to an expression for the corresponding transport coefficient. The resulting instability gives rise to banded flow profiles in glassy systems for low shear rates.


Author(s):  
Peter Huang ◽  
Jeffrey Guasto ◽  
Kenneth Breuer

The possible existence of slip of liquids in close proximity to a smooth surface is studied experimentally via the dynamics of small particles suspended in a shear flow. Sub-micron fluorescent particles suspended in water are imaged and analyzed using Total Internal Reflection Velocimetry (TIRV). For water flowing over a hydrophilic surface, the measurements are in agreement with previous experiments and indicate that slip, if present, is minimal at low shear rates, but increases slightly as the shear rate increases. Furthermore, surface hydrophobicity can be attributed for additional shear-rate dependent boundary slip. Issues associated with the experimental technique and the interpretation of results are also discussed.


2016 ◽  
Vol 12 (3) ◽  
pp. 4322-4339
Author(s):  
Salah Hamza

Knowledge of rheological properties of polymer and their variation with temperature and concentration have been globally important for processing and fabrication of polymers in order to make useful products. Basheer et al. [1] investigated, experimentally, the changes in rheological properties of metallocene linear low density polyethylene (mLLDPE) solutions by using a rotational rheometer model AR-G2 with parallel plate geometry. Their work covered the temperature range from  to  and  concentration from  to . In this paper, we reconsider Basheer work to describe the rheological behavior of mLLDPE solutions and its dependence on concentration and temperature.Until now, several models have been built to describe the complex behavior of polymer fluids with varying degrees of success. In this article, Oldroyd 4-constant, Giesekus and Power law models were tested for investigating the viscosity of mLLDPE solution as a function of shear rate. Results showed that Giesekus and power law models provide the best prediction of viscosity for a wide range of shear rates at constant temperature and concentration. Therefore, Giesekus and power law models were suitable for all mLLDPE solutions while Oldroyd 4-constant model doesn't.A new proposed correlation for the viscosity of mLLDPE solutions as a function of shear rate, temperature and concentration has been suggested. The effect of temperature and concentration can be adequately described by an Arrhenius-type and exponential function respectively. The proposed correlation form was found to fit the experimental data adequately.


Blood ◽  
2009 ◽  
Vol 114 (22) ◽  
pp. 1518-1518
Author(s):  
Tamas Alexy ◽  
Thomas D. Coates ◽  
John C Wood ◽  
Herbert J. Meiselman ◽  
Rosalinda B Wenby ◽  
...  

Abstract Abstract 1518 Poster Board I-541 Introduction Chronic blood transfusions are commonly used as therapy for sickle cell disease (SCD, HbSS) in order to improve oxygen delivery and minimize complications such as stroke in high-risk children. Vaso-occlusive crises can occur in regions of high shear flow (e.g., major cerebral artery occlusions) or regions of low shear flow (e.g., marrow infarct) leading to acute ischemia and, if severe, to necrosis of affected tissues. Transfusion with normal (AA) RBC causes an increase of hematocrit (H) that is complicated by two opposing factors: increased hematocrit (H) causes a linear increase of oxygen carrying capacity and also an exponential increase of blood viscosity (η). As a consequence, the calculated oxygen transport effectiveness, defined as the ratio of H to η (H/η), is a biphasic function of hematocrit: H/η initially increases with H, reaches a maximum at an optimal H value, and then declines with further increases of H. At equal H and shear rate, sickle (SS) blood has significantly higher viscosity than AA and hence part of the strategy for transfusing SCD patients is to reduce η so as to improve H/η. Viscosity studies at high shear rates indicate that an optimum H can be demonstrated for AA-SS RBC mixtures prepared by adding AA RBC to SS blood to simulate transfusion. In marked contrast, low shear rate results for AA-SS mixtures indicate that there is no optimum hematocrit and H/η always decreases with increasing H (Transfusion 46:912-918, 2006). In order to extend these previous in vitro observations to SCD patients, we have measured blood viscosity and hematocrit using whole blood samples acquired prior to and following routine therapeutic transfusion; H/η was calculated over a wide, physiologically relevant shear rate range. Methods All subjects (n= 8, mean age =18.7 years) had homozygous HbSS disease, were crisis-free for > 4 weeks, and were enrolled in a chronic transfusion protocol designed to yield < 30% HbS and a post-transfusion H of 30-35%. Blood samples were obtained pre- and within 120 hours post-transfusion. A computer-controller tube viscometer was used to determine blood viscosity (37 °C, 40 mm Hg oxygen tension) over a shear rate range of 1 – 1,000 1/s. Results 1) As anticipated, blood viscosity and the degree of non-Newtonian flow behavior increased with H (24.7% pre-transfusion, 34.6% post-transfusion); 2) the change of H/η from pre- to post- transfusion was markedly affected by shear rate (Figure). As indicated, there is a large adverse effect at low shear (i.e., H/η reduced by 20-25% following transfusion), a neutral effect at about 50-100 1/s, and an improved H/η at high shear (Figure). That is, transfusion with AA RBC to obtain a lower percent SS RBC and a higher H actually impairs oxygen transport effectiveness at low shear and is only beneficial at high shear. Conclusions Clinical experience suggests that transfusion regimens aimed a keeping HbS at 30-50% are effective in preventing recurrent strokes in high-risk children. However, our new in vivo transfusion data suggest that at low shear rates, %HbS must be reduced further for H/η to surpass pre-transfusion levels. We interpret these findings as being consistent with our previous data for AA-SS RBC mixtures. They are also consistent with clinical results indicating lack of efficacy for transfusion in low flow areas (e.g., bone marrow during acute crisis) but highly beneficial effects in high flow regions (e.g., cerebral arteries). Our results thus suggest that benefits of transfusion may vary depending on local flow rates (i.e., shear rates) and organ-specific hemodynamics. Disclosures No relevant conflicts of interest to declare.


1967 ◽  
Vol 40 (5) ◽  
pp. 1483-1491
Author(s):  
Yoshio Ito

Abstract Nonnewtonian flow of poly(dimethyl siloxanes) of various molecular weights has been studied with a short capillary viscosimeter. The experiment covered a wide range of shear rate, from 10−1 to 3×106sec−1. Results were as follows: (1) Flow behavior of the sample changes with the degree of polymerization. For siloxanes with degrees of polymerization less than 1.55×102, flow of the fluid is newtonian throughout the whole range of shear rates; for siloxanes with degrees of polymerization from 3.22×102 to 2.63×103, flow is nonnewtonian at moderate shear rates; it again becomes newtonian at high shear rates. With degrees of polymerization more than 3.31×103, the spiral flow rises to a high shear rate. (2) Plow behavior of the samples is expressed by modifying Shishido's equation proposed for nonnewtonian polymer solutions. (3) When the observed flow curve contains its inflection point, the upper newtonian viscosity can be estimated by a new method proposed here. (4) The relations among the end correction of capillary, the pressure loss, and the shear stress proposed by Shishido for polymer solutions are applicable to poly(dimethy! siloxane) also.


1985 ◽  
Vol 60 ◽  
Author(s):  
John R Morris ◽  
W Roger Cannon

AbstractRheology and the component interactions which affect rheology were studied for a tape casting composition similar to commercial systems. Viscosity measurements at different shear rates were compared to measured tape properties to determine if high or low shear rate rheological behavior controls tape characteristics. Relative viscosity was measured to assess the contribution of each component to the stability of the dispersion.


2009 ◽  
Vol 296 (4) ◽  
pp. G750-G754 ◽  
Author(s):  
Norman R. Harris ◽  
Joseph R. Whatley ◽  
Patsy R. Carter ◽  
Georgia A. Morgan ◽  
Matthew B. Grisham

Adoptive transfer of naïve CD4+T cells into lymphopenic mice induces chronic small and large bowel inflammation similar to Crohn's disease. Although much is now known regarding the immunopathology in this model of inflammatory bowel disease, virtually nothing is known about the microvascular hemodynamic changes during the induction and perpetuation of chronic gut inflammation. In this study, CD4+CD45RBhighT cells obtained from healthy C57BL/6 donor mice were transferred into lymphopenic recombinase-activating gene-1-deficient (RAG knockout) mice, which induced small and large bowel inflammation. At various time points following reconstitution (3 days-9 wk), intravital microscopy was used to examine the microvessels in the submucosa of the ileum and proximal colon following infusion of fluorescently labeled platelets and injection of rhodamine 6G (to label leukocytes). Hemodynamic measurements and the extent of blood cell adhesion to the venular wall were compared with measurements in unreconstituted RAG knockout controls. In <1 wk following reconstitution, velocity and wall shear rate of the arterioles decreased by >50% compared with controls, with this decrease also observed at 4–5 and 7–9 wk postreconstitution. At 7–9 wk, arteriolar diameters were found to be ∼15% larger than in controls, but, despite this dilation, flow rates in the individual vessels were decreased by ∼30%. Venular platelet and leukocyte adherence were not significantly elevated above controls; however, an association was found between platelet adherence and venular shear rate. In summary, significant decreases in arteriolar velocity and shear rates are observed in this model of chronic gut inflammation.


Sign in / Sign up

Export Citation Format

Share Document