High Sensitivity Sulphite Membrane Selective Electrode and its Application

2021 ◽  
Vol 43 (4) ◽  
pp. 451-451
Author(s):  
Sukru Kalayci Sukru Kalayci

In this study, the new sulphite sensitive ion-selective electrode (ISE) was prepared. The ISE was prepared from a combination of 5% perfluorooctanesulfonic acid (PFOS), 40% PVC and 55% dibutylphthalate (DBF).The sensitivity of the ISE to 1.0x10- 7-1.0x10-1 M sulphite concentration was 58 and#177; 4 mV. Electrode sensitivity was characterized. The response time of this electrode is short and 30 s. The lifetime of ISE was approximately 210 days when used five times a day. It was determined that it can work at any pH value. It is not sensitive to anions and cations that may be present in the determination medium. The detection limit of the electrode against the sulfide concentration was measured as 1.2x10-8 M. The amount of sulfites in dried apricots in Turkey, was measured with electrodes. Sulfite amount in dried apricot was determined as 2.328 and#177; 0.2417 mg / kg according to the average of 5 experiments and 95% confidence interval. The same sample was measured with DPP as 2.521 and#177; 0.2785.The validation of the obtained results in each case was proved by statistical “t” and “F” tests.

2012 ◽  
Vol 9 (1) ◽  
pp. 308-312 ◽  
Author(s):  
Hassan Ali Zamani ◽  
Hossein Behmadi

The 3-methyl-1H-1,2,4-triazole-5-thiol (MTH) was used as a suitable ionophore for fabrication of a new gadolinium(III) ion selective potentiometric sensor. Nitrobenzene (NB) was used as plasticizing solvent mediator and sodium tetraphenyl borate (NaTPB) as an anion excluder. It displays a Nernstian response (19.8± 0.4 mV/decade) in the concentration range of 1.0×10-7to 1.0×10-2M with the detection limit of 7.3×10-8M. The sensor has a very short response time (<10s) and can be used the pH range of 2.9-8.4. electrode was successfully applied as an indicator for gadolinium determination in titration with EDTA.


2010 ◽  
Vol 7 (3) ◽  
pp. 284-287
Author(s):  
Ani Mulyasuryani ◽  
Qonitah Fardiyah ◽  
Rizki Sugiri

The iodate-selective electrode based on the principle of precipitation reaction could be made by coating the platinum wire with silver iodate (AgIO3). In this research was carried out optimization the iodate-selective electrode using chitosan membrane as an AgIO3 support. The AgIO3 were added in the 2 mL 1% chitosan solution, is 0.5 to 2.5 % (w/v). The thickness of the membrane used is 6 to 12 µm. The electrode cell potential is measured against Ag/AgCl electrode as a reference electrode. The optimum electrode performance was at 2.0 % of AgIO3 with thickness a membrane of 10 µm. The iodate-selective electrode has a Nernstian factor is 52.96 mV/decade and a response time of 10 seconds. The concentration range was determined from 10-3 M to 10-1 M and the detection limit is 1.12 x 10-5 M.   Keywords:  Ion Selective Electrode, Iodate, Chitosan Membrane


2015 ◽  
Vol 12 (1) ◽  
pp. 188-196
Author(s):  
Baghdad Science Journal

A new method for construction ion-selective electrode (ISE) by heating reaction of methyl orange with ammonium reineckate using PVC as plasticizer for determination methyl orange and determination Amitriptyline Hydrochloried drug by formation ion-pair on electrode surface . The characteristics of the electrode and it response as following : internal solution 10-4M , pH (2.5-5) ,temperature (20-30) and response time 2 sec. Calibration response for methyl orange over the concentrationrange 10-3 -10-9 M with R=0.9989 , RSD%=0.1052, D.O.L=0.315X10-9 MEre%=(-0.877- -2.76) , Rec%.=(97.230 -101.711) .


2020 ◽  
Vol 44 (41) ◽  
pp. 17849-17853
Author(s):  
Yanxia Qiao ◽  
Rui Zhang ◽  
Fangyuan He ◽  
Wenli Hu ◽  
Xiaowei Cao ◽  
...  

A glucose sensor based on conductive Ni-MOF nanosheet arrays/CC exhibits a fast response time, a low detection limit, a high sensitivity, and it can also be applied for the detection of glucose in human serum samples.


RSC Advances ◽  
2016 ◽  
Vol 6 (43) ◽  
pp. 37085-37092 ◽  
Author(s):  
Ying Yang ◽  
Li Sun ◽  
Xiangting Dong ◽  
Hui Yu ◽  
Tingting Wang ◽  
...  

Fe3O4nanoparticles-decorated reduced graphene oxide nanocomposites have been successfully synthesized using solvothermal-pyrolytic method. They have superior gas sensing performance with low detection limit, high sensitivity and short response time.


2008 ◽  
Vol 6 (4) ◽  
pp. 607-612 ◽  
Author(s):  
Cecylia Wardak

AbstractA new all plastic sensor for Co2+ ions based on 2-amino-5 (hydroxynaphtyloazo-1′)-1,3,4 thiadiazole (ATIDAN) as ionophore was prepared. The electrode exhibits a low detection limit of 1.5 × 10−6 mol L−1 and almost theoretical Nernstian slope in the activity range 4.0 × 10−6–1 × 10−1 mol L−1 of cobalt ions. The response time of the sensor is less than 10 s and it can be used over a period of 6 months without any measurable divergence in potential. The proposed sensor shows a fairly good selectivity for Co(II) over other metal ions. The electrode was successfully applied for determination of Co2+ in real samples and as an indicator electrode in potentiometric titration of Co2+ ions with EDTA.