Development of High Performance Liquid Chromatographic Estimation of Domperidone and Lansoprazole

Author(s):  
Pooja Agarwal ◽  
Beena Kumari ◽  
Sangeeta Sangeeta ◽  
Manish Kumar

The combination of Domperidone and Lansoprazole is very useful in Gastro-esophageal disinfection (Dyspepsia). These methods provide means to separate the components characterize and quantify the components. An accurate, precise, specific and simple HPLC method was developed for simultaneous estimation of Domperidone and Lansoprazole. By this method retention time, linearity and accuracy data is respectively found for Domperidone and Lansoprazole. Mobile phase was prepared by mixing 51 volume of Acetonitrile and 49 volume of Ammonium Acetate (51:49 V/V) then 25mg each of Domperidone and Lansoprazole was dissolved in small volume of Acetonitrile: Ammonium Acetate (51:49 V/V) separately. Retention time was recorded 4.330 ± 0.003 minute and 5.820 ± 0.003 minute for Domperidone and Lansoprazole with 1.0 ml/min flow rate. The low value of % R.S.D indicates that this method is precise and accurate. Thus it can be concluded that the proposed method was good approach for obtaining reliable result.

Author(s):  
Grishma H Patel ◽  
Shreya D Adeshra ◽  
Dhananjay B Meshram

A Novel, selective, accurate and rapid Reversed Phase High Performance Liquid Chromatographic (RPHPLC) method for the analysis of Efonidipine Hydrochloride Ethanolate and Telmisartan in binary mixture has been developed and validated. The chromatographic system consisted of a Phenomenex Kinetex ® 5µ C18 Size: 150 * 4.6mm column and the separation was achieved by using ambient temperature with a mobile phase containing mobile Phase Acetonitrile:25mM Phosphate Buffer pH 4.9 (45:55). The samples were monitored at 253 nm for detection at a flow rate of 1.0 mL/min and the retention time was about 7.77 and 4.10 mins for Efonidipine Hydrochloride Ehanolate and Telmisartan respectively. The calibration curve was linear over the concentration range 5-30 and 10-60 ?g/mL for Efonidipine Hydrochloride Ehanolate and Telmisartan respectively. The proposed method is accurate in the range of 99.75% - 100.10% recovery and precise (%RSD of intraday variation and % RSD of inter day variation were found to be within the acceptance criteria). Therefore, this method can be used as a more convenient and efficient option for the analysis of Efonidipine Hydrochloride Ehanolate and Telmisartan in Quality control laboratory.


Author(s):  
DYADE GK ◽  
SAWANT RL

Objective: A reverse-phase high-performance liquid chromatographic (RP-HPLC) method was developed and validated for the simultaneous estimation of amlodipine besylate (AD) and valsartan (VAL) in pharmaceutical dosage form, and rosuvastatin (RV) and VAL from the bulk mixture. Method: Chromatographic separation was performed on RP-C18 column. The optimized unique mobile phase (acetonitrile:water and pH adjusted to 4.8 with acetic acid) was pumped at a flow rate of 0.8 ml/min in the ratio of 75:25% v/v, and the eluents were monitored at 245 nm. Results: The assay was performed with tablet and percentage of assay was found to 101.39 for AD and 100.05 for VAL, respectively, and with bulk mixture, percentage of assay was found to 99.58 for RV and 100.32 for VAL, respectively. Linearity was obtained in the concentration range of 1–12 μg/ml for AD, 5–50 μg/mL for VAL, and 2–20 μg/ml for RV. The method was statistically validated and RSD was found to be <2%, indicating high degree of accuracy and precision of the proposed RP-HPLC method. Conclusions: The method suggests usefulness of unique mobile phase during the estimation of two or more multicomponent dosage forms. Due to its simplicity, rapidness, high precision, and accuracy, the proposed RP-HPLC method can be applied for simultaneous determination of AD and VAL in pharmaceutical dosage form, and RV and VAL in bulk mixture.


2011 ◽  
Vol 8 (s1) ◽  
pp. S41-S46
Author(s):  
Prafulla Kumar Sahu ◽  
M. Mathrusri Annapurna ◽  
Dillipkumar Sahoo

This paper describes a high-performance liquid chromatographic method for simultaneous estimation of nabumetone and paracetamol in binary mixture. The method was based on RP-HPLC separation and quantitation of the two drugs on hypersil C-18 column (250 mm × 4.6 mm) using a mobile phase consisting of acetonitrile and 0.05% aqueous acetic acid (70:30v/v) at flow rate of 1 mL min-1. Quantitation was achieved with PDA detector at 238 nm based on peak area with linear calibration curves at concentration ranges 5-25 µg mL-1for both the drugs. Naproxen sodium was used as internal standard. The method has been successively applied to pharmaceutical formulation. No chromatographic interference from the tablet excipients was found. The method was validated in terms of precision, robustness, recovery and limits of detection and quantitation. The intra and inter-day precision and accuracy values were in the acceptance range as per ICH guidelines.


2013 ◽  
Vol 2013 ◽  
pp. 1-4
Author(s):  
Suying Ma ◽  
Haixia Lv ◽  
Xiaojun Shang

A high performance liquid chromatographic (HPLC) method with UV detector for the determination of dyclonine hydrochloride and a gas chromatography (GC) method with flame ionization detector (FID) for the determination of camphor and menthol in lotion were developed. The developed HPLC method involved using a SinoChoom ODS-BP C18reversed-phase column (5 μm, 4.6 mm × 200 mm) and mobile phase consisting of acetonitrile : water : triethylamine in a ratio of 45 : 55 : 1.0; pH was adjusted to 3.5 with glacial acetic acid. The developed GC method for determination of camphor and menthol involved using an Agilent 19091J-413 capillary chromatographic column (30 m × 320 μm × 0.25 μm). The two methods were validated according to official compendia guidelines. The calibration of dyclonine hydrochloride for HPLC method was linear over the range of 20–200 μg/mL. The retention time was found at 6.0 min for dyclonine hydrochloride. The calibration of camphor and menthol of GC method was linear over the range of 10–2000 μg/mL. The retention time was found at 2.9 min for camphor and 3.05 min for menthol. The proposed HPLC and GC methods were proved to be suitable for the determination of dyclonine hydrochloride, camphor, and menthol in lotion.


INDIAN DRUGS ◽  
2012 ◽  
Vol 49 (09) ◽  
pp. 27-32
Author(s):  
V. S Reddy ◽  
◽  
T. E. G. K. Murthy ◽  
N Usha Rani ◽  
R. S Rao ◽  
...  

A simple, precise, accurate, reproducible, robust reverse phase high-performance liquid chromatographic method was developed for the simultaneous estimation of frovatriptan, almotriptan and zolmitriptan in bulk and pharmaceutical dosage forms. The method was validated as per ICH and FDA guidelines. Analysis of the drugs was performed on Phenomenex Chromosil C-18 (250 x 4.6 mm, 5 mc) column, in an isocratic mode employing methanol, acetonitrile and THF in the ratio of 46:50:04 (v/v/v) as mobile phase. UV-visible detector at 269 nm was found to be suitable for detection. Linearity was observed in the range of 40-100 ppm.The % recovery was found to be 99.51, 99.69 and 99.34 for frovatriptan, almotriptan and zolmitriptan respectively. The % RSD values for method precision was found to be 0.86, 0.65 and 1.28 for frovatriptan, almotriptan and zolmitriptan respectively. Limit of quantification (LOQ) and limit of detection (LOD) values were found to be 0.15, 0.08 and 0.09 ppm. and 0.05, 0.02, 0.03 for frovatriptan, almotriptan and zolmitriptan respectively.


INDIAN DRUGS ◽  
2015 ◽  
Vol 52 (08) ◽  
pp. 12-16
Author(s):  
S Vidyadhara ◽  
◽  
L. S Reddyvalam ◽  
T. Koduri ◽  
P. K. Borra ◽  
...  

A simple, accurate, precise high-performance liquid chromatographic (HPLC) method has been developed and validated for the simultaneous determination of abacavir sulphate (ABA) and lamivudine (LAM) in combined dosage form. Separation was performed on a C18 column [Agilent ODS UG 5 column, 250 mm x 4.5 mm], with methanol: water (50:50 V/V) isocratic elution using a flow rate of 1mL/min. Good sensitivity was observed with UV detection at 277 nm. After method development, the interference of other active compounds and excipients, repeatability and linearity, were investigated. Retention times of LAM and ABA were found to be 3.3 and 6.3 min, respectively. The method was validated over the range from 2.5-12.5 μg/mL for LAM and 5-25 μg/mL for ABA with correlation coefficients of 0.9997 and 0.9996, respectively. This method was shown to be accurate, robust, selective, linear, and repeatable and can be successfully employed in routine quality control for the simultaneous analysis of ABA and LAM in tablets.


2010 ◽  
Vol 93 (4) ◽  
pp. 1228-1235 ◽  
Author(s):  
Mohamed Walash ◽  
Mohamed Metwally ◽  
Manal Eid ◽  
Rania El-Shaheny

Abstract A micellar HPLC method was developed for analysis of the antiosteoporosis drug risedronate. The analysis was carried out using a 250 4.6 mm id, 5 m particle size C18 Waters Symmetry column. The mobile phase consisted of 0.02 M sodium dodecyl sulfate + 0.3 triethylamine + 10 n-propanol, prepared in 0.02 M orthophosphoric acid. The pH of the mobile phase was adjusted to pH 6.0, and it was pumped at a flow rate of 0.7 mL/min with UV detection at 262 nm. The method showed good linearity in the range of 280 g/mL, with an LOD of 0.40 g/mL (1.31 106 M) and an LOQ of 1.21 g/mL. The suggested method was successfully applied for the analysis of risedronate in raw material and a tablet formulation, with average recoveries of 99.91 1.30 and 101.52 0.30, respectively. The stability-indicating capability of the proposed method was proved using forced degradation. By changing the pH of the mobile phase to 4.0, the oxidative degradation product could be separated from risedronate.


1982 ◽  
Vol 65 (5) ◽  
pp. 1063-1065
Author(s):  
Stanley E Roberts

Abstract A high performance liquid chromatographic (HPLC) method is described for the quantitative determination of primidone in tablets. A ground tablet sample is diluted directly in the mobile phase, at a concentration of about 1 mg/mL of primidone, mixed and deaerated, and filtered. The resulting solution is then quantitated by HPLC. The average spike recoveries for the 50 mg and 250 mg tablets were 101.2% and 99.0%, respectively. The average recovery for an authentic mixture formulated at the 250 mg level was 100.1% with a relative standard deviation of 0.45%.


2021 ◽  
Vol 37 (02) ◽  
pp. 493-498
Author(s):  
Mohan Bhatale ◽  
Neelakandan Kaliyaperumal ◽  
Gopalakrishnan Mannathusamy ◽  
Gurunathan Ramalingam

A simple, selective, linear having accuracy and specific of reverse phase high-performance liquid chromatographic (RP-HPLC) method for determination of Genotoxic impurity Hydroxylamine Hydrochloride of drug Leflunomide is reported.The separation and analysis were done on YMC Triart C18 (4.6 mm x 150 mm), having particle size 3.0 μm. KH2PO4 in 2000 mL of purified water and 2 mL triethylamine with pH 2.5 with phosphoric acid is mobile phase-A while acetonitrile is mobile Phase-B with gradient program. The elution achieved with 1.50 mL/min flow rate and using UV detection at 230 nm wavelength. Selected column oven temperature is 45°C and auto sampler 5°C respectively. In this method linearity and accuracy of Hydroxylamine HCl covered with specification limit of LOQ to 150 % (i.e.3 to 23 ppm). The observed correlation coefficient is 0.99965 and recovery in between 99.07 to 114.94. In method precision (ie.repeatability) and intermediate precision (IP) observed % RSD of six spiked test preparation is below 5.0 %. The standard and sample were stable for 3 days when stored at 2 to 8°C temperature. In robustness studies system suitability parameters ie tailing factor, theoretical plates and %RSD does not show significant changes. The present RP-HPLC method is selective, robust, linear, and precise for detection of Hydroxylamine HCl.


2018 ◽  
Vol 8 (6-s) ◽  
pp. 78-82 ◽  
Author(s):  
Vishal Singh Solanki ◽  
RAM SINGH BISHNOI ◽  
Raviraj Baghel ◽  
Deepti Jain

A simple precise and economical reverse phase high performance liquid chromatographic method has been developed and validated for the simultaneous estimation of Cilnidipine (CDP), Atenolol (ATL) and Chlorthalidone (CTD).The chromatographic separation was achieved by using Hypersil- keystone C18 (4.6 x 250mm, 5μm) under isocratic conditions The mobile phase consisted of methanol and triple distilled water (80/20, v/v) having pH 7 with a flow rate of 1.0 mL/min. The eluents were monitored at 225 nm for simultaneous measurement.The selected chromatographic conditions were found to effectively separate CDP (Rt: 3.25 min), ATL (Rt: 5.366 min) and CTD (Rt: 9.025 min) having good resolution. The developed method was validated for linearity, accuracy, precision, LOD, LOQ, robustness and for system suitability parameters as per ICH guidelines. In this study, an excellent linearity was obtained with r2 = 0.999, r² = 0.999, r² = 1, for CDP, ATL and CTD respectively. The developed chromatographic method proved to be simple, precise, accurate, robust and reproducible Thus, this method would be employed for routine simultaneous quantification of CDP, ATL and CTD in bulk form or tablet dosage form.   Keywords: Cilnidipine, Atenolol and Chlorthalidone, RP-HPLC.