scholarly journals Piezo-Optical Transducers in High Sensitive Strain Measurements

2020 ◽  
Author(s):  
Andrey G. Paulish ◽  
Peter S. Zagubisalo ◽  
Sergey M. Churilov ◽  
Vladimir N. Barakov ◽  
Mikhail A. Pavlov ◽  
...  

New piezo-optical sensors based on the piezo-optical effect for high sensitive mechanical stress measurements have been proposed and developed. The piezo-optical method provides the highest sensitivity to strains compared to sensors based on any other physical principles. Piezo-optical sensors use materials whose parameters practically not change under load or over time, therefore piezo-optical sensors are devoid of the disadvantages inherent in strain-resistive and piezoelectric sensors, such as hysteresis, parameters degradation with time, small dynamic range, low sensitivity to strains, and high sensitivity to overloads. Accurate numerical simulation and experimental investigations of the piezo-optical transducer output signal formation made it possible to optimize its design and show that the its gauge factor is two to three orders of magnitude higher than the gauge factors of sensors of other types. The cruciform shape of the transducer photoelastic element made it possible to significantly increase the stresses in its working area at a given external force. Combining compactness, reliability, resistance to overloads, linearity and high sensitivity, in terms of the all set of these parameters, piezo-optical sensors significantly surpass the currently widely used strain-resistive, piezoelectric and fiber-optic sensors and open up new, previously inaccessible, possibilities in the tasks of measuring power loads.

2019 ◽  
Vol 14 (1) ◽  
Author(s):  
Zhongyun Yuan ◽  
Zhen Pei ◽  
Muhammad Shahbaz ◽  
Qiang Zhang ◽  
Kai Zhuo ◽  
...  

AbstractSoft-strain-based sensors are being increasingly used across various fields, including wearable sensing, behavior monitoring, and electrophysiological diagnostics. However, throughout all applications, the function of these sensors is limited because of high sensitivity, high-dynamic range, and low-power consumption. In this paper, we focus on improving the sensitivity and strain range of the soft-strain-based sensor through structure, surface, and sensitive unit treatment. Nanosilver (Ag)-coated hydroxyl-functionalized multi-walled carbon nanotubes (OH-f MWCNTs) were explored for highly acute sensing. With stretching and depositing methods, Ag@OH-f MWCNTs and polydimethylsiloxane (PDMS) are fabricated into a wrinkled and sandwich structure for a soft-strain-based sensor. The electronic properties were characterized in that the gauge factor (GF) = ΔR/R0 was 412.32, and the strain range was 42.2%. Moreover, our soft-strain-based sensor exhibits features including flexibility, ultra-lightweight and a highly comfortable experience in terms of wearability. Finally, some physiological and behavioral features can be sampled by testing the exceptional resistance change, including the detection of breath, as well as facial and hand movement recognition. The experiment exhibits its superiority in terms of being highly sensitive and having an extensive range of sensing.


2004 ◽  
Vol 3 (1) ◽  
pp. 1-16 ◽  
Author(s):  
Jorge García de la Nava ◽  
Sacha van Hijum ◽  
Oswaldo Trelles

We present a mathematical model to extend the dynamic range of gene expression data measured by laser scanners. The strategy is based on the rather simple but novel idea of producing two images with different scanner sensitivities, obtaining two different sets of expression values: the first is a low-sensitivity measure to obtain high expression values which would be saturated in a high-sensitivity measure; the second, by the converse strategy, obtains additional information about the low-expression levels. Two mathematical models based on linear and gamma curves are presented for relating the two measurements to each other and producing a coherent and extended range of values. The procedure minimizes the quantization relative error and avoids the collateral effects of saturation. Since most of the current scanner devices are able to adjust the saturation level, the strategy can be considered as a universal solution, and not dependent on the image processing software used for reading the DNA chip. Various tests have been performed, on both proprietary and public domain data sets, showing a reduction of the saturation and quantization effects, not achievable by other methods, with a more complete description of gene-expression data and with a reasonable computational complexity.


Sensors ◽  
2021 ◽  
Vol 21 (22) ◽  
pp. 7437
Author(s):  
Siheng Xiang ◽  
Hui You ◽  
Xinxiang Miao ◽  
Longfei Niu ◽  
Caizhen Yao ◽  
...  

Stretchable optical fiber sensors (SOFSs), which are promising and ultra-sensitive next-generation sensors, have achieved prominent success in applications including health monitoring, robotics, and biological–electronic interfaces. Here, we report an ultra-sensitive multi-functional optical micro/nanofiber embedded with a flexible polydimethylsiloxane (PDMS) membrane, which is compatible with wearable optical sensors. Based on the effect of a strong evanescent field, the as-fabricated SOFS is highly sensitive to strain, achieving high sensitivity with a peak gauge factor of 450. In addition, considering the large negative thermo-optic coefficient of PDMS, temperature measurements in the range of 30 to 60 °C were realized, resulting in a 0.02 dBm/°C response. In addition, wide-range detection of humidity was demonstrated by a peak sensitivity of 0.5 dB/% RH, with less than 10% variation at each humidity stage. The robust sensing performance, together with the flexibility, enables the real-time monitoring of pulse, body temperature, and respiration. This as-fabricated SOFS provides significant potential for the practical application of wearable healthcare sensors.


2006 ◽  
Vol 113 ◽  
pp. 453-458 ◽  
Author(s):  
R. Navickas ◽  
V. Barzdenas

Hybrid pixel sensors (detectors) have shown to be a valid alternative to other types of Xray imaging devices due to their high sensitivity, linear behavior and wide dynamic range, and low noise. One important feature of these devices is the fact that detectors and readout electronics are manufactured separately. The charge created by the interaction of X-ray photons in the sensor is very small and has to be amplified in a low-noise circuit before any further signal processing. The signal induced on the electrodes of the sensor is transferred to the readout chip, where it is integrated in a charge sensitive amplifier. The issue reviews on physical principles of operation and design of the hybrid pixel sensors developed on the basis of the silicon CMOS and GaAs MESFETtechnologies. The authors have designed GaAs charge sensitive amplifiers for hybrid pixel detectors and show the results of a simulation.


Author(s):  
F. Ouyang ◽  
D. A. Ray ◽  
O. L. Krivanek

Electron backscattering Kikuchi diffraction patterns (BKDP) reveal useful information about the structure and orientation of crystals under study. With the well focused electron beam in a scanning electron microscope (SEM), one can use BKDP as a microanalysis tool. BKDPs have been recorded in SEMs using a phosphor screen coupled to an intensified TV camera through a lens system, and by photographic negatives. With the development of fiber-optically coupled slow scan CCD (SSC) cameras for electron beam imaging, one can take advantage of their high sensitivity and wide dynamic range for observing BKDP in SEM.We have used the Gatan 690 SSC camera to observe backscattering patterns in a JEOL JSM-840A SEM. The CCD sensor has an active area of 13.25 mm × 8.83 mm and 576 × 384 pixels. The camera head, which consists of a single crystal YAG scintillator fiber optically coupled to the CCD chip, is located inside the SEM specimen chamber. The whole camera head is cooled to about -30°C by a Peltier cooler, which permits long integration times (up to 100 seconds).


Author(s):  
N. Mori ◽  
T. Oikawa ◽  
Y. Harada ◽  
J. Miyahara ◽  
T. Matsuo

The Imaging Plate (IP) is a new type imaging device, which was developed for diagnostic x ray imaging. We have reported that usage of the IP for a TEM has many merits; those are high sensitivity, wide dynamic range, and good linearity. However in the previous report the reading system was prototype drum-type-scanner, and IP was also experimentally made, which phosphor layer was 50μm thick with no protective layer. So special care was needed to handle them, and they were used only to make sure the basic characteristics. In this article we report the result of newly developed reading, printing system and high resolution IP for practical use. We mainly discuss the characteristics of the IP here. (Precise performance concerned with the reader and other system are reported in the other article.)Fig.1 shows the schematic cross section of the IP. The IP consists of three parts; protective layer, phosphor layer and support.


Nanophotonics ◽  
2020 ◽  
Vol 9 (5) ◽  
pp. 1081-1086 ◽  
Author(s):  
Abdoulaye Ndao ◽  
Liyi Hsu ◽  
Wei Cai ◽  
Jeongho Ha ◽  
Junhee Park ◽  
...  

AbstractOne of the key challenges in biology is to understand how individual cells process information and respond to perturbations. However, most of the existing single-cell analysis methods can only provide a glimpse of cell properties at specific time points and are unable to provide cell secretion and protein analysis at single-cell resolution. To address the limits of existing methods and to accelerate discoveries from single-cell studies, we propose and experimentally demonstrate a new sensor based on bound states in the continuum to quantify exosome secretion from a single cell. Our optical sensors demonstrate high-sensitivity refractive index detection. Because of the strong overlap between the medium supporting the mode and the analytes, such an optical cavity has a figure of merit of 677 and sensitivity of 440 nm/RIU. Such results facilitate technological progress for highly conducive optical sensors for different biomedical applications.


2021 ◽  
Author(s):  
Luis David Rosales-Vazquez ◽  
Alejandro Dorazco-González ◽  
Victor Sanchez-Mendieta

Optical sensors with high sensitivity and selectivity, as important analytical tools for chemical and environmental research, can be accomplished by straightforward synthesis of luminescent one-, two- and three-dimensional Zn(II) and...


2021 ◽  
Vol 12 (1) ◽  
Author(s):  
Wenjie Yan ◽  
Huei-Ru Fuh ◽  
Yanhui Lv ◽  
Ke-Qiu Chen ◽  
Tsung-Yin Tsai ◽  
...  

AbstractThere is an emergent demand for high-flexibility, high-sensitivity and low-power strain gauges capable of sensing small deformations and vibrations in extreme conditions. Enhancing the gauge factor remains one of the greatest challenges for strain sensors. This is typically limited to below 300 and set when the sensor is fabricated. We report a strategy to tune and enhance the gauge factor of strain sensors based on Van der Waals materials by tuning the carrier mobility and concentration through an interplay of piezoelectric and photoelectric effects. For a SnS2 sensor we report a gauge factor up to 3933, and the ability to tune it over a large range, from 23 to 3933. Results from SnS2, GaSe, GeSe, monolayer WSe2, and monolayer MoSe2 sensors suggest that this is a universal phenomenon for Van der Waals semiconductors. We also provide proof of concept demonstrations by detecting vibrations caused by sound and capturing body movements.


Sign in / Sign up

Export Citation Format

Share Document