The Impact of Temperature on the Removal of Nitrogen Compounds in Activated Sludge System

2015 ◽  
Vol 11 (1) ◽  
pp. 1-13 ◽  
Author(s):  
Sylwia Myszograj
2020 ◽  
Vol 35 (3) ◽  
pp. 457-463
Author(s):  
Huixia Lan ◽  
Xiangzhi Wang ◽  
Shixin Qi ◽  
Da Yang ◽  
Hao Zhang

AbstractUsing the acclimated activated sludge from the pulping middle-stage effluent, the effect of pH shock on the micro-oxygen activated sludge system with a nano-magnetic powder/graphene oxide composite was studied. The results showed that the removal rates of chemical oxygen demand (CODCr) and ultraviolet adsorption at 254 nm (UV254) decreased. Also, the sludge settling performance was poor due to the impact of pH, but the impact resistance of nano-magnetic powder/graphene oxide group (MGO group) was higher and the recovery was faster. Results of high throughput sequencing indicated that the diversity of microbial community was reduced by the impact of pH, but it was significantly higher in MGO group than in the blank group. The dominant bacteria after pH shock or recovery in both of the system had a large difference. The percentage of the dominant bacteria in the MGO group was higher than that in the blank group. The MGO group had higher electron transfer system (ETS) activity which made the system having a strong pH impact resistance.


2008 ◽  
Vol 57 (6) ◽  
pp. 915-919 ◽  
Author(s):  
L. Zhang ◽  
L. Mendoza ◽  
M. Marzorati ◽  
W. Verstraete

Hydrogen sulfide emission in sewers is associated with toxicity, corrosion, odor nuisance and a lot of costs. The possibility to inhibit sulfide generation by formaldehyde and its derivatives (paraformaldehyde and urea formaldehyde) has been evaluated under anaerobic conditions. The impact of formaldehyde on an activated sludge system and an appraisal of the economic aspects are also presented. The optimum dosage to inhibit sulfide generation in sewage was 12–19 mg L−1 formaldehyde. The dosages of 32 mg L−1 paraformaldehyde or 100 mg L−1 urea formaldehyde were not capable of inhibiting sulfide generation in sewage. The impact of 19 mg L−1 formaldehyde on activated sludge system was negligible in terms of COD removal, nitrification rate and oxygen uptake rate.


2018 ◽  
Vol 23 (6) ◽  
pp. 1143-1152 ◽  
Author(s):  
Sandra Tedde Santaella ◽  
Maria do Socorro Vale ◽  
Clara Cabral Almeida ◽  
Willame de Araújo Cavalcante ◽  
Alberto Jorge Pinto Nunes ◽  
...  

ABSTRACT The release of wastewater and the shrimp feed cost are the main challenges faced by the shrimp farming industry. An alternative solution to both problems is biofloc production in a unit external to the farm, in an activated sludge system for effluent treatment. The treatment system’s influent was composed of the shrimp farm wastewater supplemented with urea and sugarcane molasses. The results show that the average removal of chemical oxygen demand was 71% and the average biofloc production in the reactor was approximately 1.5g.L-1. Adding molasses to the influent contributed to the increase in the quantity and diversity of existing microorganisms that are beneficial to cultured shrimp. The mass balance of nitrogen compounds confirmed that nitrification occurred in the system. Therefore, the use of the activated sludge system is a viable and environmentally suitable alternative to produce bioflocs and shrimp farming effluent treatment.


2018 ◽  
Author(s):  
Gede H Cahyana

As a part of activated sludge system, oxidation ditch has a special form like a canal without end point. Rotor is used to diffuse oxygen from air to the water.


1974 ◽  
Vol 9 (1) ◽  
pp. 235-249 ◽  
Author(s):  
S.G. Nutt ◽  
K.L. Murphy

Abstract Conventional wastewater parameters are accepted as inadequate estimates of the condition of activated sludge but numerous other indices have been suggested as specific measurements of the activity and viability of the biomass. Literature in the related fields of microbiology and biochemistry were reviewed in order to select the most appropriate activity parameters for application to a heterogeneous biological material. Modified analytical methods were applied to a well-controlled biological system containing a single predominant bacterial species to evaluate the relative merit of each as an indicator of viability and activity. The potential of each parameter in a complex heterogeneous system was determined by monitoring each index in a bench activated sludge system. The predominant culture studies indicated that the ATP content of the biomass and the dehydrogenase activity were potential indicators of cell viability in a simple system. However, in the complex activated sludge system, only the ATP content showed significant correlation to the organic carbon removal rate.


1988 ◽  
Vol 20 (11-12) ◽  
pp. 131-136 ◽  
Author(s):  
A. D. Wong ◽  
C. D. Goldsmith

The effect of discharging specific oil degrading bacteria from a chemostat to a refinery activated sludge process was determined biokinetically. Plant data for the kinetic evaluation of the waste treatment plant was collected before and during treatment. During treatment, the 500 gallon chemostatic growth chamber was operated on an eight hour hydraulic retention time, at a neutral pH, and was fed a mixture of refinery wastewater and simple sugars. The biokinetic constants k (days−1), Ks (mg/L), and K (L/mg-day) were determined before and after treatment by Monod and Lineweaver-Burk plots. Solids discharged and effluent organic concentrations were also evaluated against the mean cell retention time (MCRT). The maximum utilization rate, k, was found to increase from 0.47 to 0.95 days−1 during the operation of the chemostat. Subsequently, Ks increased from 141 to 556 mg/L. Effluent solids were shown to increase slightly with treatment. However, this was acceptable due to the polishing pond and the benefit of increased ability to accept shock loads of oily wastewater. The reason for the increased suspended solids in the effluent was most likely due to the continual addition of bacteria in exponential growth that were capable of responding to excess substrate. The effect of the chemostatic addition of specific microbial inocula to the refinery waste treatment plant has been to improve the overall organic removal capacity along with subsequent gains in plant stability.


1994 ◽  
Vol 30 (3) ◽  
pp. 73-78 ◽  
Author(s):  
O. Tünay ◽  
S. Erden ◽  
D. Orhon ◽  
I. Kabdasli

This study evaluates the characterization and treatability of 2,4-D production wastewaters. Wastewaters contain 20000-40000 mg/l COD, 17000-30000 mg/l chloride and pH is around 1.0. Chemical oxidation with hydrogen peroxide provided almost complete COD removal. The optimum conditions are 3:1 H2O2/COD oxidant dosage, 3000 mg/l Fe3+ as catalyst and pH 3. Partial oxidation at 0.5:1 H2O2//COD ratio is also effective providing 67% COD removal. A batch activated sludge system is used for biological treatability. Dilution is needed to maintain a tolerable chloride concentration which increases through COD removal. pH also increased during COD removal. 85% COD removal is obtained for the 50% dilution at an organic loading of 0.3 day‒1 on a COD basis. Completely and partially oxidized wastewaters are also treated in the activated sludge down to 30 mg/l BOD5.


Sign in / Sign up

Export Citation Format

Share Document