atmospheric pressure ionization
Recently Published Documents


TOTAL DOCUMENTS

380
(FIVE YEARS 29)

H-INDEX

48
(FIVE YEARS 2)

Separations ◽  
2022 ◽  
Vol 9 (1) ◽  
pp. 13
Author(s):  
Juli Novita Sari ◽  
Karthikeyan Kandasamy ◽  
Yu-Chie Chen

Escherichia coli are common pathogens, whereas E. coli O157:H7 is the most notorious E. coli strain, owing to its high virulence that can cause serious adverse effects and death. E. coli contains abundant peroxidases. Thus, the presence of E. coli can be determined by mixing E. coli with its substrate such as 3,5,3′,5′ tetramethylbenzidines (TMB) for endogenous peroxidase reactions. Under the presence of a high concentration of E. coli, colorless TMB turned to bluish, owing to the generation of the complexity of TMB and its oxidized TMB. To further reduce the detectable cell concentration, we developed an affinity-based method combined with an endogenous peroxidase reaction and mass spectrometric detection to detect E. coli. Affinity probes (diameter: ~20 µm) modified with maltose were generated for the enrichment of E. coli from sample solutions. E. coli trapped by the affinity probes was reacted with TMB in the presence of hydrogen peroxide for endogenous peroxidase reactions. Contactless atmospheric pressure ionization mass spectrometry was used for the detection of the reaction product, oxidized TMB (TMB cationic radical), to indicate the presence of target bacteria. The results showed that the developed method can be used to rapidly determine the presence of E. coli from a sample solution based on the detection of the TMB cationic radicals. The lowest detectable concentration of our method against E. coli O157:H7 in buffers and in complex juice samples was as low as ~100 cfu mL−1.


Molecules ◽  
2021 ◽  
Vol 26 (22) ◽  
pp. 6911
Author(s):  
Xiaolei Li ◽  
Frank L. Dorman ◽  
Paul A. Helm ◽  
Sonya Kleywegt ◽  
André Simpson ◽  
...  

Gas chromatography–high-resolution mass spectrometry (GC–HRMS) is a powerful nontargeted screening technique that promises to accelerate the identification of environmental pollutants. Currently, most GC–HRMS instruments are equipped with electron ionization (EI), but atmospheric pressure ionization (API) ion sources have attracted renewed interest because: (i) collisional cooling at atmospheric pressure minimizes fragmentation, resulting in an increased yield of molecular ions for elemental composition determination and improved detection limits; (ii) a wide range of sophisticated tandem (ion mobility) mass spectrometers can be easily adapted for operation with GC–API; and (iii) the conditions of an atmospheric pressure ion source can promote structure diagnostic ion–molecule reactions that are otherwise difficult to perform using conventional GC–MS instrumentation. This literature review addresses the merits of GC–API for nontargeted screening while summarizing recent applications using various GC–API techniques. One perceived drawback of GC–API is the paucity of spectral libraries that can be used to guide structure elucidation. Herein, novel data acquisition, deconvolution and spectral prediction tools will be reviewed. With continued development, it is anticipated that API may eventually supplant EI as the de facto GC–MS ion source used to identify unknowns.


Separations ◽  
2021 ◽  
Vol 8 (8) ◽  
pp. 111
Author(s):  
Yen-Chun Chen ◽  
Arun Krishnamurthy ◽  
Szu-Hua Chen ◽  
Yu-Chie Chen

Capillary electrophoresis (CE) is an effective technique for the separation of different analytes. Moreover, online preconcentration of trace analytes in the capillary for CE analysis has been demonstrated. CE and capillary electrochromatography (CEC) are suitable for the separation of analytes with similar polarities. Given that CE and CEC are only used to separate small-volume samples, sensitive mass spectrometry (MS) is a suitable detection tool for CE and CEC. Contactless atmospheric pressure ionization (C-API) is a continuous flow ion source that only uses a short capillary as the ionization emitter operated at atmospheric pressure for MS analysis. In this study, we demonstrated the feasibility of hyphenating CE/CEC with C-API-MS by using a short and tapered capillary as the interface. The short capillary (a few centimeters) can function as the separation/preconcentration tube and the ionization emitter. This hyphenated technique can be used to analyze small organics within a few minutes. The suitability of using the hyphenated technique for online preconcentration, separation, and quantitative analysis for small organics is demonstrated in this study.