titanium oxide film
Recently Published Documents


TOTAL DOCUMENTS

113
(FIVE YEARS 9)

H-INDEX

15
(FIVE YEARS 2)

2021 ◽  
Vol 9 (6) ◽  
pp. 449-463
Author(s):  
Vyacheslav Ivanov ◽  
Mikhail Konyzhev ◽  
Tatyana Kamolova ◽  
Anna Dorofeyuk

The propagation and structure of a microplasma discharge initiated in vacuum by a pulsed plasma flow with a density of 1013 cm–3 on the surface of a titanium sample covered with a thin continuous dielectric titanium oxide film with a shickness of 2–6 nm were studied experimentally when the electric current of the discharge changes from 50 A to 400 A. It was found that the microplasma discharge glow visually at the macroscale has a branched structure of the dendrite type, which at the microscale consists of a large number of brightly glowing “point” formations – cathode spots localized on the metal surface. The resulting erosion structure on the titanium surface is visually “identical” to the structure of the discharge glow and consists of a large number of separate non-overlapping microcraters with characteristic sizes from 0.1–3 μm, which are formed at the sites of localization of cathode spots at distances of up to 20 μm from each other. It was found that the propagation of a single microplasma discharge over the titanium surface covered with a thin oxide film a thickness of 2–6 nm occurs at an average velocity of 15–70 m/s when the amplitude of the discharge electric current changes in the range of 50–400 A. In this case, the microplasma discharge propagation on the microscale has a “jumping” character: the plasma of “motionless” burning cathode spots, during their lifetime 1 μs, initiates the excitation of new microdischarges, which create new cathode spots at localization distances of 1–20 μm from the primary cathode spots. This process repeated many times during a microplasma dis- charge pulse with a duration from 0.1 ms to 20 ms.


2021 ◽  
Vol 8 (3) ◽  
Author(s):  
Xiangping Chen ◽  
Xin Li ◽  
Dedong Chen ◽  
Lishi Wang

Anodization is a widely used method to obtain multicoloured oxidized titanium sheets. However, most researchers paid great attention to the colour-related properties instead of photoelectrical properties of titanium oxide film obtained by anodization. In this work, to study their photoelectrical properties, a series of multicoloured oxidized titanium sheets were prepared by anodization method, and UV–vis absorption and photocurrents were tested. The relationship between anodization voltages/anodization durations and photocurrents of titanium sheets was studied. Results show that titanium sheets have excellent photoelectrical performance. With the increase of anodization voltage, the number of UV–vis absorption peaks increased under visible light which means increasing absorption. When anodization duration increased, absorption band edge also increased in the visible light region, which means the band gap needed to produce charge transfer transition decreased. Under simulated sunlight and applied voltage of +0.4 V, photocurrent increased with the increase of either anodization voltage or anodization duration, and can be expressed by linear equations. In addition, anodization currents were recorded during anodization. Morphology, crystal structure and photoelectrical properties of anodized titanium sheets were characterized. The anodized titanium sheets can not only be used as decorative material in jewellery and architecture fields etc. but also are supposed to be used as photoelectrical catalyst in further work.


Metals ◽  
2020 ◽  
Vol 10 (9) ◽  
pp. 1272
Author(s):  
Júlio C. M. Souza ◽  
Karin Apaza-Bedoya ◽  
Cesar A. M. Benfatti ◽  
Filipe S. Silva ◽  
Bruno Henriques

The main aim of this work was to perform a comprehensive review of findings reported by previous studies on the corrosion of titanium dental implants and consequent clinical detrimental effects to the patients. Most studies were performed by in vitro electrochemical tests and complemented with microscopic techniques to evaluate the corrosion behavior of the protective passive oxide film layer, namely TiO2. Results revealed that bacterial accumulation, dietary, inflammation, infection, and therapeutic solutions decrease the pH of the oral environment leading to the corrosion of titanium. Some therapeutic products used as mouthwash negatively affect the corrosion behavior of the titanium oxide film and promote changes on the implant surface. In addition, toothpaste and bleaching agents, can amplify the chemical reactivity of titanium since fluor ions interacting with the titanium oxide film. Furthermore, the number of in vivo studies is limited although corrosion signs have been found in retrieved implants. Histological evaluation revealed titanium macro- and micro-scale particles on the peri-implant tissues. As a consequence, progressive damage of the dental implants and the evolution of inflammatory reactions depend on the size, chemical composition, and concentration of submicron- and nanoparticles in the surrounding tissues and internalized by the cells. In fact, the damage of the implant surfaces results in the loss of material that compromises the implant surfaces, implant-abutment connections, and the interaction with soft tissues. The corrosion can be an initial trigger point for the development of biological or mechanical failures in dental implants.


2019 ◽  
Vol 2019 ◽  
pp. 1-8
Author(s):  
Ryoji Sawada ◽  
Yuya Katou ◽  
Hirofumi Shibata ◽  
Max Katayama ◽  
Toru Nonami

Titanium-based materials are widely used for implant treatments such as artificial dental roots. Surface treatment has the potential to improve not only the biocompatibility but also the chemical and mechanical durability of the surface without changing the mechanical properties of the metal. A relatively thick titanium oxide film can be formed by the anodic oxidation method. Phosphoric acid or sulfuric acid electrolytic solution has previously been used for anodic oxidation. Such anodized films have excellent film hardness, abrasion resistance, and adhesion. In this study, titanium plate was anodized using an aqueous solution of sulfuric acid in which titanium oxide powder was suspended. A 2800-nm-thick titanium oxide film was formed, which was thicker than that obtained using phosphoric acid electrolyte. The titanium plate was immersed in simulated body fluid for 1 day to evaluate the photocatalytic activity and protein adsorption ability, and a homogeneous crack-free hydroxyapatite layer was formed. This titanium plate showed high methylene blue bleaching capacity. The adsorption ability of the acidic protein of the anodized titanium plate subjected to the above treatment was high. This suggests that this titanium plate has antimicrobial properties and protein adsorption ability. Thus, we report that a titanium plate, anodized with a sulfuric acid aqueous electrolyte solution containing suspended TiO2 powder and immersed in simulated body fluid, might behave as an antibacterial and highly biocompatible implant material.


2019 ◽  
Vol 363 ◽  
pp. 430-435 ◽  
Author(s):  
Y.X. Leng ◽  
J. Wang ◽  
P. Yang ◽  
J.Y. Chen ◽  
Nan Huang

2019 ◽  
Vol 45 (6) ◽  
pp. 6875-6884 ◽  
Author(s):  
Shyam Bharatkumar Patel ◽  
Nik Radevski ◽  
Nicholas Mondinos ◽  
Xiaoli Zhao ◽  
Kevin Jack ◽  
...  

2018 ◽  
Vol 10 (12) ◽  
pp. 1742-1749
Author(s):  
Tianlin Fu ◽  
Zhiwen Wang ◽  
Ruijia Diao ◽  
Xiaohua Yu ◽  
Zhentao Yuan ◽  
...  

Sign in / Sign up

Export Citation Format

Share Document