optimum operating condition
Recently Published Documents


TOTAL DOCUMENTS

65
(FIVE YEARS 20)

H-INDEX

6
(FIVE YEARS 1)

2021 ◽  
Author(s):  
Mohammed Al Sawafi ◽  
Antonio Andrade ◽  
Nitish Kumar ◽  
Rahul Gala ◽  
Eduardo Marin ◽  
...  

Abstract Petroleum Development Oman (PDO) has been a pioneer in improving Well management processes utilizing its valuable human resources, continuous improvement and digitalization. Managing several PCP wells through Exception Based Surveillance (EBS) methodology had already improved PCP surveillance and optimization across assets. The key to trigger EBS was to keep Operating Envelope (OE), Design Limits updated in Well Management Visualization System (WMVS) after every change in operating speed (RPM), workover and new completion. The sustainable solution was required for automatic update of OEs, having well inflow potential and oil gain opportunities available for quicker optimization decisions for further improvements. PDO has completed a project automating PCP well modeling process where models are built and sustained automatically in Well Management System (WMS) for all active PCP wells, with huge impact on day-to-day operational activities. The paper discusses utilization of physics based well models from WMS to automatically update OE, identify oil gain potential daily and enable real time PCP performance visualization in WMVS. The integration of WMS and WMVS was completed to share data between two systems and automatically update well's OE daily. A tuned well model from WMS was utilized to provide well performance data and sensitivity analysis results for various RPMs. Among the various data obtained from WMS, live OE of torque and fluid above pump (FAP) for various speeds, operating limits, design limits, locked in potential (LIP) for optimization and pump upsize were utilized to process PCP well EBS and create live OE visualization. The visualization is created on a torque-speed chart where a live OE and FAP can be observed in provided picture with current RPM and torque with optimum operating condition. The project is completed after conducting successful change management across PDO assets and after thorough analysis of implementation following benefits were observed: 5% net gain of total PCP production is being executed with zero CAPEX using LIP reports. 50% of engineer's time was saved by updating OEs in WMVS automatically, reduction of false EBS and EBS rationalization. 200% improvement in PCP well performance diagnostics capabilities of Engineers. 15% CAPEX free optimization and pump upsize cases were identified based on well inflow potential. 100% visibility to PCP well's performance was achieved using well model. The visualization has supported engineers monitoring well performance in real time and easily identifying ongoing changes in well and pump performance. PCP well models have supported engineers in new PCP well design and pump upsize. The current efforts in utilizing real time well models, inferred production, automating processes to update OE is one more step toward Digitalization of PCP Surveillance and optimization and to achieve self well optimization for further improving operational efficiency.


2021 ◽  
Vol 920 (1) ◽  
pp. 012019
Author(s):  
N A M Hussin ◽  
C Z A Abidin ◽  
Fahmi ◽  
A H Ibrahim ◽  
R Ahmad ◽  
...  

Abstract The degradation of anthraquinone dye Reactive Blue 19 by using O3 and O3 / S2O8 2- in the advanced oxidation processes is studied to investigate the performance of these two systems. The response surface method with a Box-behnken Design was successfully applied to identify the relationship between operating variables such as initial concentration, S2O8 2- dosage and contact time in order to determine the optimum operating condition. The quadratic model for the percentage COD removal (response) proved to be significant for the degradation of the dye. The COD removal efficiency under Box-behnken Design and experimental test were found to be 96.2% and 83.9% under the optimum conditions. Furthermore, the result obtained showed that the O3 / S2O8 2- system is more effective than the O3 only in treating the Reactive Blue 19.


Electronics ◽  
2021 ◽  
Vol 10 (18) ◽  
pp. 2226
Author(s):  
Ratil H. Ashique ◽  
Md Hasan Maruf ◽  
Kazi Md Shahnawaz Habib Sourov ◽  
Md Mahadul Islam ◽  
Aminul Islam ◽  
...  

This paper presents a comparative analysis of the class E and selected enhanced class E inverters, namely, the second and third harmonic group of class EFn, E/Fn and the class E Flat Top inverter. The inverters are designed under identical specifications and evaluated against the variation of switching frequency (f), duty ratio (D), capacitance ratio (k), and the load resistance (RL). To offer a comparative understanding, the performance parameters, namely, the power output capability, efficiency, peak switch voltage and current, peak resonant capacitor voltages, and the peak current in the lumped network, are determined quantitatively. It is found that the class EF2 and E/F3 inverters, in general, have higher efficiency and comparable power output capability with respect to the class E inverter. More specifically, the class EF2 (parallel LC and in series to the load network) and E/F3 (parallel LC and in series to the load network) maintain 90% efficiency compared to 80% for class E inverter at the optimum operating condition. Furthermore, the peak switch voltage and current in these inverters are on average 20–30% lower than the class E and other versions for k > 1. The analysis also shows that the class EF2 and E/F3 inverters should be operated in the stretch of 1 < k < 5 and D = 0.3–0.6 at the optimum load to sustain the high-performance standard.


2021 ◽  
Vol 10 (2) ◽  
pp. 100-116
Author(s):  
Abdulkareem Abubakar ◽  
Ijai Ezekiel Waba ◽  
Suleiman Yunusa ◽  
Zaharaddeen Sani Gano

Improper handling of wastewater from various industries causes environmental pollution. Hence, this study involved using a reactivated spent FCC catalyst, a cheap and reliable adsorbent for Pb2+ removal from refinery-based simulated wastewater. In contrast, response surface methodology (RSM) was used to determine the optimum operating condition. The adsorptive capacity of the reactivated spent FCC catalyst was observed using different parameters such as temperature, pH, adsorbent dosage, and contact time. At the end of the study, it was found that the optimum condition for removing Pb2+ was at pH of 7, adsorbent dose of 1.75 g, contact time of 75 mins, and temperature of 117 oC. At this condition, the maximum removal efficiency of Pb2+ was found to be 100 %. A quadratic model equation via central composite design under the RSM was developed to predict the Pb2+ removal from all the input parameters. Based on the F-statistic values, the temperature had the greatest influence on the removal of Pb2+ while adsorbent dosage and contact time were also significant.  


Author(s):  
Robert Eliraison Moshi ◽  
Thomas Thomas Kivevele ◽  
Yusufu Abeid Chande Jande

Municipal solid waste (MSW) is becoming a concern as population in urban area is increasing. Several disposal methods (landfill and biochemical) have been used. However, waste to energy (WTE) particularly gasification technology is a potential technology for energy recovery. The system is used to convert biodegradable material into syngas under limited gasifying media. This study presents numerical analysis of producer gas for the two air paths in the hybrid fixed bed gasifier (HFBG). It was revealed that the optimum operating condition was achieved when the air ratio at the first air flow path (AIR1) was 0.3. Furthermore, the exergy efficiency of about 81.51% was   achieved.


2021 ◽  
Vol 12 ◽  
Author(s):  
Wei Wang ◽  
Suxia Shao ◽  
Wei Chen ◽  
Weizhou Wang ◽  
Yunhai Chuai ◽  
...  

Oocytes reconstructed by spindle transfer (ST) are prone to chromosome abnormality, which is speculated to be caused by mechanical interference or premature activation, the mechanism is controversial. In this study, C57BL/6N oocytes were used as the model, and electrofusion ST was performed under normal conditions, Ca2+ free, and at room temperature, respectively. The effect of enucleation and electrofusion stimulation on MPF activity, spindle morphology, γ-tubulin localization and chromosome arrangement was compared. We found that electrofusion stimulation could induce premature chromosome separation and abnormal spindle morphology and assembly by decreasing the MPF activity, leading to premature activation, and thus resulting in chromosome abnormality in oocytes reconstructed via ST. Electrofusion stimulation was an independent factor of chromosome abnormality in oocytes reconstructed via ST, and was not related to enucleation, fusion status, temperature, or Ca2+. The electrofusion stimulation number should be minimized, with no more than 2 times being appropriate. As the electrofusion stimulation number increased, several typical abnormalities in chromosome arrangement and spindle assembly occurred. Although blastocyst culture could eliminate embryos with chromosomal abnormalities, it would significantly decrease the number of normal embryos and reduce the availability of embryos. The optimum operating condition for electrofusion ST was the 37°C group without Ca2+.


Author(s):  
P. V. Wakchaure

This paper presents the experimental analysis performed on ejectors to optimize operating conditions like evaporator temperature, condenser temperature and generator temperature. Using the environmentally friendly working fluid R134a, R152a, R600a, R717 (Ammonia). Parametric analysis was performed to review the effect of blending chamber geometry on ejector performance which has direct impact on coefficient of performance of ejector refrigeration cycles. Results show that operating conditions and thus the effect of the deflection of the primary flow on the secondary flow is set. CFD simulations was performed to identify optimum geometry and optimum operating condition


2021 ◽  
Author(s):  
Steven James England

A geothermal system for suspended oil wells is designed to produce 1.25MW of heat. After a review of literature, a concentric double pipe heat exchanger was the system chosen. A control volume model was created to calculate the heat transfer characteristics of the system. After completing the model a suspended oil well near Hinton, Alberta was selected as a candidate well for a geothermal system. The well contains 33 perforated sections which need to be closed off. Three designs to accomplish this are proposed. The model predicted that the best design uses cement squeezes to close off the perforations and produces a net energy of 2.4MW at its optimum operating condition, with a mass flow rate of 8.18kg/s. When producing 1.25MW of heat, the design has a net energy of 1.2MW. It is found that internal heat generation plays a large roll in these systems.


2021 ◽  
Author(s):  
Steven James England

A geothermal system for suspended oil wells is designed to produce 1.25MW of heat. After a review of literature, a concentric double pipe heat exchanger was the system chosen. A control volume model was created to calculate the heat transfer characteristics of the system. After completing the model a suspended oil well near Hinton, Alberta was selected as a candidate well for a geothermal system. The well contains 33 perforated sections which need to be closed off. Three designs to accomplish this are proposed. The model predicted that the best design uses cement squeezes to close off the perforations and produces a net energy of 2.4MW at its optimum operating condition, with a mass flow rate of 8.18kg/s. When producing 1.25MW of heat, the design has a net energy of 1.2MW. It is found that internal heat generation plays a large roll in these systems.


Author(s):  
Yohanita Restu Widihastuty ◽  
Sutini Sutini ◽  
Aida Nur Ramadhani

Pineapple leaf waste is one agricultural waste that has high cellulose content. Pineapple leaf waste's complex structure contains a bundle of packed fiber that makes it hard to remove lignin and hemicellulose structure, so challenging to produce reducing sugar. Dried pineapple leaf waste pretreated with a grinder to break its complex structure. Delignification process using 2% w/v NaOH solution at 87oC for 60 minutes has been carried out to remove lignin and hemicellulose structure so reducing sugar could be produced. Delignified pineapple leaf waste has been enzymatic hydrolyzed using cellulase enzyme (6 mL, 7 mL, and 8 mL) to produce reducing sugar. The sample was incubated in an incubator shaker at 155 rpm at 45, 55, and 60oC for 72 hours. Determination of reducing sugar yield had been carried out using the Dubois method and HPLC. The model indicated that the optimum operating condition of enzymatic hydrolysis is 7 mL of cellulase enzyme at 55oC to produce 96,673 mg/L reducing sugar. This result indicated that the enzymatic hydrolysis operating condition improved the reducing sugar yield from pineapple leaf waste. The optimum reducing sugar yield can produce biofuel by the saccharification process.


Sign in / Sign up

Export Citation Format

Share Document