packed tower
Recently Published Documents


TOTAL DOCUMENTS

120
(FIVE YEARS 16)

H-INDEX

16
(FIVE YEARS 1)

2021 ◽  
Vol 11 (1) ◽  
pp. 441
Author(s):  
Eun Ju Kim ◽  
Ho Kim ◽  
Eunsil Lee

This study analyzed the influence of different ammonia stripping parameters on ammonia removal efficiency and mass transfer rate. Ammonia stripping was performed on two devices, a column and a packed tower, with artificial ammonium hydroxide wastewater. First, ammonia concentration and pH were varied in a column without liquid circulation. At the same pH, the removal efficiency and mass transfer rate were constant, irrespective of initial ammonia concentration. When pH was increased, the ammonia fraction also increased, resulting in higher removal efficiency and mass transfer rate. Second, the effects of stripping were assessed using a packed tower with fluid circulation. The ammonium hydroxide concentration did not affect the removal efficiency or mass transfer rate. Furthermore, at apparatus liquid-gas ratios of 26.8–107.2 L/m3, a lower liquid-gas ratio led to increased ammonia removal efficiency and mass transfer rate. Conversely, the lower the liquid-gas ratio, the greater the air consumption. In conclusion, considering the removal rate and volume of air supply, the range of optimal liquid-gas ratio was determined as 26.8–53.6 L/m3. In particular, the 26.8 L/m3 condition achieved the best ammonia removal rate of 63.0% through only 6 h of stripping at 70 °C and pH 8.5.


ACS Omega ◽  
2020 ◽  
Vol 5 (29) ◽  
pp. 17931-17939
Author(s):  
Hao Huang ◽  
Hui Hu ◽  
Maohong Fan ◽  
Changchao Ruan ◽  
Kunpeng Li ◽  
...  

Catalysts ◽  
2020 ◽  
Vol 10 (4) ◽  
pp. 426
Author(s):  
Antonio de Jesús Zúñiga-Mendiola ◽  
Diana Rosa Gómora-Herrera ◽  
Juan Manuel García-González ◽  
Javier Guzmán-Pantoja

The CO2 absorption process using aqueous solutions of lysine (Lys), the ionic liquid (IL) tetrabutyl phosphonium lysinate ([TBP][Lys]) and their mixtures was studied by means of a packed tower. The performance of these systems was evaluated through the volumetric overall mass transfer coefficient ( K G a V ) , conducting experiments under diverse conditions such as inlet CO2 concentration from 10 to 40 vol.%, gas and absorbent flow rates from 100 to 200 mL/min and from 3 to 5 mL/min, respectively, absorbent concentration from 5 to 15 wt.% and temperature from 15 to 40 °C. The obtained results for all the previous experimental conditions were better for the IL/Lys mixture than for the isolated components; the best performance was shown by the experiment varying the absorbent concentration, where the increasing K G a V was benefited by the IL/Lys synergistic effect.


Sign in / Sign up

Export Citation Format

Share Document