inhibin a
Recently Published Documents


TOTAL DOCUMENTS

556
(FIVE YEARS 44)

H-INDEX

49
(FIVE YEARS 2)

Animals ◽  
2021 ◽  
Vol 11 (12) ◽  
pp. 3493
Author(s):  
Maria Montserrat Rivera del Alamo ◽  
Tiina Reilas ◽  
Karolina Lukasik ◽  
Antonio M. Galvão ◽  
Marc Yeste ◽  
...  

Intrauterine devices (IUDs) are used in mares to suppress oestrous behaviour, but the underlying mechanism is yet to be elucidated. The presence of an embryo or an IUD prevents cyclooxygenase-2 (COX-2) and, subsequently, prostaglandin (PG) release and luteolysis. However, inflammation may also be involved. Endometrial inflammatory markers in uterine lavage fluid were measured on Day 10 (EXP 1, n = 25) and Day 15 (EXP 2, n = 27) after ovulation in inseminated mares, non-pregnant or pregnant, and in mares in which a small plastic sphere had been inserted into the uterus 4 (EXP 1) or 3 days (EXP 2) after ovulation. Uterine lavage fluid samples were analysed for nitric oxide (NO), prostaglandin E2 (PGE2) (only Exp. 1), prostaglandin F2α (PGF2α), inhibin A and cytokines, and blood samples for progesterone and oestradiol. On Day 10, the concentration of PGF2α was lower (p < 0.05) in the IUD group than in pregnant mares. The concentration of the modulatory cytokine IL-10 was significantly higher in the IUD group in comparison to non-pregnant mares, and inhibin A was significantly higher in IUD mares than in the pregnant counterparts on Day 15. The results suggest that the presence of IUD causes endometrial inflammation which is at a resolution stage on Day 15.


Medicina ◽  
2021 ◽  
Vol 57 (7) ◽  
pp. 651
Author(s):  
Praetip Praikaew ◽  
Kuntharee Traisrisilp ◽  
Chanane Wanapirak ◽  
Ratanaporn Sekararithi ◽  
Theera Tongsong

Background and Objectives: To establish normative models for median levels of serum biomarkers of the second trimester quad test (alpha-fetoprotein: AFP; free beta-human gonadotropins: hCG; inhibin-A; and unconjugated estriol: uE3) specific to Thai women and to compare multiples of the median (MoMs) derived from ethnicity-specific models and those derived from Caucasian models with ethnic correction. Materials and Methods: A cross-sectional study was undertaken in a tertiary, medical teaching center among low-risk pregnant Thai women between 14 and 21 weeks of gestation to measure the levels of the four serum biomarkers. The measured values of each biomarker were analyzed using the multivariable factorial polynomial technique for quantile regression as a function of gestational age and maternal weight. Results: The Thai-specific normative models for the four biomarkers were generated and available for use. The MoMs of all individuals generated from our models were significantly different from conventional (Caucasian) models with ethnic correction (Wilcoxon signed-rank test; p < 0.0001 for all biomarkers). The MoMs of AFP and hCG from both methods were in agreement, but those from Thai-specific models were significantly higher. However, those of inhibin-A and uE3 were markedly different and ethnic correction was unlikely to be useful. Conclusions: The Thai-specific normative models of the quad test as a function of gestational age and maternal weight were constructed using multivariable factorial polynomial models, better than simple quantile regression or log-linear regression used in earlier decades. The analysis of MoMs supports the use of ethnicity-specific models instead of Caucasian models with ethnic correction.


Author(s):  
Elina Keikkala ◽  
Janina Forstén ◽  
Olli Ritvos ◽  
Ulf-Håkan Stenman ◽  
Eero Kajantie ◽  
...  
Keyword(s):  

Author(s):  
Hymavathi K. ◽  
Sandhya Rani Davuluru ◽  
Sameera Shaik ◽  
Sahithi Kaviti

Background: This study was conducted to evaluate the efficacy of different biochemical and biophysical markers in the early weeks of gestation as screening tools for early prediction of preeclampsia.Methods: This hospital-based prospective observational study conducted on 52 pregnant women, at less than 13 weeks of gestation were recruited. Maternal serum inhibin A and USG uterine artery PI levels were analyzed among the pregnant women who subsequently developed PE and compare with those who did not develop PE. Methods used for the detection of markers were: chemiluminescence immunoassay (CLIA) for serum inhibin A levels, and uterine artery Doppler velocimetry was done by PHILIPS HD11XE transabdominal ultrasound machine using a 4-6 MHz probe with the same sonographer.Results: The present study revealed a significant rise of inhibin A in preeclamptic women when compared to normotensive women (p<0.0001). The mean levels of 1st and 2nd trimester uterine artery PI significantly high in women who subsequently developed PE when compared to those who did not develop preeclampsia (p<0.0001). Study results showed a strong association between gestational age at delivery and neonatal outcome (neonatal birth weight and APGAR) with preeclampsia. The maternal serum inhibin A, and uterine artery PI found to have good sensitivity and specificity for early prediction of PE.Conclusions: Study concluded that the women who are prone to develop PE subsequently, had high levels of MAP, UAPI, inhibin A. In our setting, MAP, UAPI, inhibin A, appeared to be better screening modalities. Combination of the biochemical markers with the biophysical markers, demographic characteristics, and other novel markers will establish the effective screening models for early prediction of PE. Early identification of high-risk cases will offer an opportunity for prophylactic therapy, such as Low- dose Aspirin in selected groups of high-risk women screened in the first trimester, thus improving the maternal and perinatal outcome.


Lupus ◽  
2021 ◽  
Vol 30 (6) ◽  
pp. 981-990
Author(s):  
Sir-Yeon Hong ◽  
Seo-Yeon Kim ◽  
Jin-Ha Kim ◽  
Jee-Youn Hong ◽  
Ji-Hee Sung ◽  
...  

Purpose We investigated the validity of quad serum markers for the prediction of adverse pregnancy outcome (APO) in women with antiphospholipid antibody syndrome (APS). Methods We included 75 women with APS delivered at our institution. APO was defined as stillbirth, small for gestational age (SGA), severe preeclampsia, or preterm delivery. First, we compared clinical characteristics between patients with or without composite APO. Second, we compared the rate of APO according to abnormal level of quad serum markers. Lastly, receiver operating characteristic (ROC) curve analysis was performed. Results APS mothers with APO showed higher median α-fetoprotein (AFP) and inhibin A compared with those without APO. They were also associated with higher rates of positive risk of Down syndrome and neural tube defect. Elevated AFP, human chorionic gonadotropin (hCG), and inhibin A level was associated with higher rates of stillbirth, SGA, preterm delivery, and composite APO. ROC curve for prediction of stillbirth revealed an area under the curve of 0.835 for AFP, 0.781 for hCG, and 0.932 for inhibin A. For composite APO, the area under the ROC curve was 0.692 for AFP and 0.810 for inhibin A. Conclusion Elevated AFP, hCG, and inhibin A in women with APS demonstrated a high predictive value for APO, especially stillbirth.


2021 ◽  
Vol 2 (1) ◽  
pp. 35-49
Author(s):  
Adi Sharabi-Nov ◽  
Tanja Premru Sršen ◽  
Kristina Kumer ◽  
Vesna Fabjan Vodušek ◽  
Teja Fabjan ◽  
...  

Objective: We previously provided evidence to confirm that maternal serum levels of soluble Fms-like tyrosine kinase-1 (sFlt-1), placental growth factor (PlGF), and their ratio are useful tools to direct the management of preeclampsia (PE), fetal growth restriction (FGR), and PE+FGR near delivery. In this secondary analysis, we further examine the potential additive value of maternal serum Inhibin-A, which is a hormone marker of the transforming growth factor family, to the accuracy provided by maternal serum PlGF and sFlt-1. Methods: We conducted a secondary analysis where we extracted the data of a cohort of 125 pregnant women enrolled near delivery at the clinics of the University Medical Center of Ljubljana, Slovenia. The dataset included 31 cases of PE, 16 of FGR, 42 of PE+FGR, 15 preterm delivery (PTD), and 21 unaffected controls with delivery of a healthy baby at term. Cases delivered before 34 weeks’ gestation included 10 of PE, 12 of FGR, 28 of PE+FGR, and 6 of PTD. In addition to the recorded demographic characteristics and medical history and the maternal serum levels of PlGF and sFlt-1/PlGF ratio, which were previously published, we evaluated the added value of maternal serum Inhibin-A. The predictive accuracy of each biomarker, their ratios, and combinations were estimated from areas under the curve (AUC) of receiver operating characteristics (ROC) curves, Box and Whisker plots, and by multiple regression. We estimated accuracy by the continuous marker model and a cutoff model. Results: In this study, we combined Inhibin-A with PlGF or with the sFlt-1/PlGF ratio and showed a 10–20% increase in AUCs and 15–45% increase in the detection rate, at 10% false positive rate, of PE, and a lower, but significant, increase for PE+FGR and FGR in all cases but not for FGR in early cases delivered < 34 weeks. The use of a cutoff model was adequate, although a bit higher accuracy was obtained from the continuous model. The highest correlation was found for PlGF with all three complications. Conclusion: In this secondary analysis, we have found that maternal serum Inhibin-A improves the accuracy of predicting PE and PE+FGR provided by maternal serum angiogenic markers alone, bringing the results to a diagnostic level; thus, it could be considered for directing clinical management. Inhibin-A had smaller or no added value for the accuracy of predicting FGR alone, mainly of early cases delivered <34 weeks.


Author(s):  
Adi Sharabi-Nov ◽  
Tanja Premru Sršen ◽  
Kristina Kumar ◽  
Vesna Fabjan Vodušek ◽  
Teja Fabjan ◽  
...  

Objective: We previously provided evidence to confirm that soluble Fms-like tyrosine kinase-1 (sFlt-1), placental growth factor (PlGF), and their ratio, are useful tools to direct the management of preeclampsia (PE), fetal growth restriction (FGR), and PE+FGR near delivery. In this study we examine the potential additive value of Inhibin-A, a hormone marker of the transforming growth factor family. Methods: We used a cohort of 125 pregnant women enrolled near delivery at clinics of the University Medical Center of Ljubljana, Slovenia. There were 31 cases of PE, 16 of FGR, 42 of PE+FGR, 15 iatrogenic preterm delivery (PTD), and 21 unaffected controls with delivery of a healthy baby at term. Cases delivered before 34 weeks&rsquo; gestation included 13 of PE, 12 of FGR, 22 of PE+FGR, and 6 of PTD. We recorded demographic characteristics and medical history and the levels of PlGF, sFlt-1 and Inhibin-A. The predictive accuracy of each biomarker, their ratios, and combinations was estimated from areas under the curve (AUC) of Receiver Operating Characteristics (ROC) curves. We estimated accuracy by the continuous marker model and a cut-off model. Results: Combining Inhibin-A with PlGF or with the sFlt-1 / PlGF ratio showed a 10-20% increase in AUCs and 5-15% increase in the detection rate, at 10% false positive rate, of PE, and a lower, but significant, increase for PE+FGR but not for FGR alone. The use of a cut-off model was adequate, although a bit higher accuracy was obtained from the continuous model. Highest correlation was found for PlGF with all three complications. Conclusion: Inhibin-A improves the accuracy of predicting PE and PE+FGR provided by the angiogenic markers alone, bringing the results to a diagnostic level, thus assisting in directing clinical management. Inhibin-A had no added value for the accuracy of predicting FGR alone.


Sign in / Sign up

Export Citation Format

Share Document