drift time
Recently Published Documents


TOTAL DOCUMENTS

127
(FIVE YEARS 35)

H-INDEX

14
(FIVE YEARS 2)

2022 ◽  
Author(s):  
Roberto Fernandez-Maestre ◽  
Mahmoud Tabrizchi ◽  
Dairo Meza-Morelos

Ion mobility spectrometry is widely used for the detection of illegal substances and explosives in airports, ports, custom, some stations and many other important places. This task is usually complicated by false positives caused by overlapping the target peaks with that of interferents, commonly associated with samples of interest. Shift reagents (SR) are species that selectively change ion mobilities through adduction with analyte ions when they are introduced in IMS instruments. This characteristic can be used to discriminate false positives because the interferents and illegal substances respond differently to SR depending on the structure and size of analytes and their interaction energy with SR. This study demonstrates that ion mobility shifts upon introduction of SR depend, not only on the ion masses, but on the interaction energies of the ion:SR adducts. In this study, we introduced five different SRs using ESI-IMS-MS to study the effect of the interaction energy and size on mobility shifts. The mobility shifts showed a decreasing trend as the molecular weight increased for the series of compounds ethanolamine, valinol, serine, threonine, phenylalanine, tyrosine, tributylamine, tryptophan, desipramine, and tribenzylamine. It was proved that the decreasing trend was partially due to the inverse relation between the mobility and drift time and hence, the shift in drift time better reflects the pure effect of SR on the mobility of analytes. Yet the drift time shift exhibited a mild decrease with the mass of ions. Valinol pulled out from this trend because it had a low binding energy interaction with all the SR and, consequently, its clusters were short-lived. This short lifetime produced fewer collisions against the buffer gas and a drift time shorter compared to those of ions of similar molecular weight. Analyte ion:SR interactions were calculated using Gaussian. IMS with the introduction of SR could be the choice for the free-interferents detection of illegal drugs, explosives, and biological and warfare agents. The suppression of false positives could facilitate the transit of passengers and cargos, rise the confiscation of illicit substances, and save money and distresses due to needless delays. Keywords: Adduction, ion mobility spectrometry, mass spectrometry, shift reagent, valinol, buffer gas modifier


Author(s):  
Mr. Nitish A. Mohite

Abstract: In the study, three dimensional analytical models of G+20 story buildings have been generated and analysed using CSI ETABS software version 2016. The earthquake zone III in India is considered for buildings during analysis. Here, the analysis and design is done of G+20 story building with flat slab(with drops) and conventional slab system. In earthquake zone the displacement and drift of the structures will be more so to have more stiffness to the structure shear wall is to be provided therefore a study is made by comparing between conventional slab & flat slab (with drops) building. Comparison of various parameters like story drift, story displacement, story stiffness and time period is done. The equivalent static method is used to design and analyze the structures, as categorized by Indian Standard Code for earthquake resistant structures. The study shows that story drift is 10% more in conventional slab as compared to flat slab; story displacements is observed linearly increasing with height of the building and is 11% more in conventional slab as compared to flat slab . Keywords: Equivalent Static Method, Flat Slab, ETABS 2016, story displacement, story stiffness, story drift, time period


2021 ◽  
Author(s):  
Yi-Chun Kuo ◽  
Kuan-Mei Hsiung ◽  
Yen-Ting Lin ◽  
Yu-Heng Tseng ◽  
Yu-San Han

Abstract The larval stage of Japanese eel travels a substantial distance over a long duration through the North Equatorial Current (NEC) and the Kuroshio, and the spawning behavior of mature eels leads to monthly arrival waves in eastern Taiwan between November and February. The total length (TL) of the glass eel relates to its larval duration and age; therefore, the TL can indicate the larval duration. The monthly mean TLs of eels along eastern Taiwan from 2010–2021 were used to estimate the batch age, and the recruitment patterns and relative abundances were compared. The TLs of glass eels followed a normal distribution, and the estimated ages were highly correlated with their mean TLs. Early recruit TLs were significantly greater than those of late recruits. The mean tracer drift time was longer in early recruitment months (November–December) than in later dates (February–March). The recruitment lag was approximately 1–1.5 months, with relative recruitment higher in the early recruitment months than in later months. Cohorts followed the main streams of the NEC and Kuroshio, and the monthly velocity changes of these currents could affect the TLs as well as the distribution patterns of Japanese glass eels in Taiwan and Japan.


2021 ◽  
Author(s):  
Kaylie I Kirkwood ◽  
Michael W Christopher ◽  
Jefferey L Burgess ◽  
Sally R Littau ◽  
Brian S Pratt ◽  
...  

Lipids play many biological roles including membrane formation, protection, insulation, energy storage, and cell division. These functions have brought great interest to lipidomic studies for understanding their dysregulation in toxic exposure, inflammation, and diseases. However, lipids have shown to be analytically challenging due to their highly isomeric nature and vast concentration ranges in biological matrices. Therefore, powerful multidimensional techniques such as those integrating liquid chromatography, ion mobility spectrometry, collision induced dissociation, and mass spectrometry (LC-IMS-CID-MS) have recently been implemented to separate lipid isomers as well as provide structural information and increased feature identification confidence. These multidimensional datasets are however extremely large and highly complex, resulting in challenges in data processing and annotation. Here, we have overcome these challenges by developing sample-specific multidimensional libraries using the freely available software Skyline. Specifically, the human plasma library developed for this work contains over 500 unique, experimentally validated lipids, which is combined with adapted Skyline functions for highly confident lipid annotations such as indexed retention time (iRT) for retention time prediction and IMS drift time filtering for increased sensitivity and selectivity. For broad comparison with other lipidomic studies, this human plasma database was initially used to annotate LC-IMS-CID-MS data from a NIST SRM 1950 extract, giving comparable results to previous studies. This workflow was then utilized to assess matched plasma and bronchoalveolar lavage fluid (BALF) samples from patients with varying degrees of smoke inhalation injury to identify potential lipid-based patient prognostic and diagnostic markers.


Molecules ◽  
2021 ◽  
Vol 26 (15) ◽  
pp. 4562
Author(s):  
Izabela Wolańska ◽  
Edyta Budzyńska ◽  
Jarosław Puton

This paper presents the results of the study on the course of the benzyl chloride (BzCl) ionization process in a drift tube ion mobility spectrometer (DT IMS) in which nitrogen was used as the carrier gas. BzCl ionization follows the dissociative electron capture mechanism. The chloride ions produced in this process take part in the formation of cluster ions. Using DT IMS allows for estimation of the value of the electron attachment rate for BzCl and the equilibrium constant for the cluster ion formation. The basic experimental method used in this work was to analyze drift time spectra obtained for the introduction of the sample to the spectrometer with the drift gas. The theoretical interpretation of the results is based on the mathematical description of the ion transport. This description takes into account the phenomenon of diffusion, as well as the processes of formation and dissociation of ionic clusters occurring during the movement of ions in the drift section.


Author(s):  
Yash Patel ◽  
Mr Jigar Zala ◽  
Prof. Deepak R. Tarachandani

P-Delta analysis affect the seismic responses of structures. When the structure responds elastically, its importance can be insignificant, but it is relevant when the structure responds to an inelastic set. The P-∆ effect normally raises the structural displacement response. Dynamic instability can also occur when the system is exposed to extreme earthquake motions. Plan irregularities can lead to substantial eccentricity between the centre of mass and the centre of rigidity in the RC framed structure, which can lead to a negative lateral and torsional response. Irregular structures require more careful structural evaluation to reach a suitable behaviour during an earthquake. In this research, a parametric study will be conducted on G+29 RC framed buildings having plan irregularity with consideration of the P-delta effect. Time history analysis, response spectrum analysis and static co-efficient method will be conducted to evaluate results of different structural systems and study the parameters like Displacement, Storey drift, Time period, Axial force, Base Shear, Bending Moment, etc with the help of structural analysis software ETABs.


2021 ◽  
Author(s):  
Roberto Fernandez-Maestre ◽  
Markus Doerr

<p><a>Racemic mixtures of twelve common </a>a-amino acids and three chiral drugs were tested for the separation of their enantiomers by ion mobility spectrometry (IMS)-quadrupole mass spectrometry (MS). Separations were tested by introducing chiral selectors in the mobility spectrometer buffer gas. (R)-α-(trifluoromethyl) benzyl alcohol, (R)-tetrahydrofuran-2-carbonitrile, (L)-ethyl lactate, methyl (S)-2-chloropropionate, and the R and S enantiomers of 2-butanol and 1-phenyl ethanol were evaluated as chiral selectors. Experimental conditions were varied during the tests including buffer gas temperature, concentration, and type of chiral selectors, analyte concentration, electrospray voltage, electrospray (ESI) solvent pH, and buffer gas flow. The individual enantiomers yielded different drift times for periods of up to 8 hours in a few experiments; such drift times were sufficiently different (~ 0.3 ms) to partially resolve the enantiomers in racemic mixtures, but these mixtures always yielded a single mobility peak at the experimental conditions tested with a drift time similar to that of one of the enantiomers. Energy calculations of the chiral selector –ion interactions showed that these separations are unlikely using 2-butanol as chiral selector but they might be feasible depending on the nature of chiral selectors and the type of enantiomers.</p>


2021 ◽  
Author(s):  
Roberto Fernandez-Maestre ◽  
Markus Doerr

<p><a>Racemic mixtures of twelve common </a>a-amino acids and three chiral drugs were tested for the separation of their enantiomers by ion mobility spectrometry (IMS)-quadrupole mass spectrometry (MS). Separations were tested by introducing chiral selectors in the mobility spectrometer buffer gas. (R)-α-(trifluoromethyl) benzyl alcohol, (R)-tetrahydrofuran-2-carbonitrile, (L)-ethyl lactate, methyl (S)-2-chloropropionate, and the R and S enantiomers of 2-butanol and 1-phenyl ethanol were evaluated as chiral selectors. Experimental conditions were varied during the tests including buffer gas temperature, concentration, and type of chiral selectors, analyte concentration, electrospray voltage, electrospray (ESI) solvent pH, and buffer gas flow. The individual enantiomers yielded different drift times for periods of up to 8 hours in a few experiments; such drift times were sufficiently different (~ 0.3 ms) to partially resolve the enantiomers in racemic mixtures, but these mixtures always yielded a single mobility peak at the experimental conditions tested with a drift time similar to that of one of the enantiomers. Energy calculations of the chiral selector –ion interactions showed that these separations are unlikely using 2-butanol as chiral selector but they might be feasible depending on the nature of chiral selectors and the type of enantiomers.</p>