array tomography
Recently Published Documents


TOTAL DOCUMENTS

112
(FIVE YEARS 35)

H-INDEX

16
(FIVE YEARS 2)

2021 ◽  
Vol 15 ◽  
Author(s):  
Daisuke Koga ◽  
Satoshi Kusumi ◽  
Masahiro Shibata ◽  
Tsuyoshi Watanabe

Scanning electron microscopy (SEM) has contributed to elucidating the ultrastructure of bio-specimens in three dimensions. SEM imagery detects several kinds of signals, of which secondary electrons (SEs) and backscattered electrons (BSEs) are the main electrons used in biological and biomedical research. SE and BSE signals provide a three-dimensional (3D) surface topography and information on the composition of specimens, respectively. Among the various sample preparation techniques for SE-mode SEM, the osmium maceration method is the only approach for examining the subcellular structure that does not require any reconstruction processes. The 3D ultrastructure of organelles, such as the Golgi apparatus, mitochondria, and endoplasmic reticulum has been uncovered using high-resolution SEM of osmium-macerated tissues. Recent instrumental advances in scanning electron microscopes have broadened the applications of SEM for examining bio-specimens and enabled imaging of resin-embedded tissue blocks and sections using BSE-mode SEM under low-accelerating voltages; such techniques are fundamental to the 3D-SEM methods that are now known as focused ion-beam SEM, serial block-face SEM, and array tomography (i.e., serial section SEM). This technical breakthrough has allowed us to establish an innovative BSE imaging technique called section-face imaging to acquire ultrathin information from resin-embedded tissue sections. In contrast, serial section SEM is a modern 3D imaging technique for creating 3D surface rendering models of cells and organelles from tomographic BSE images of consecutive ultrathin sections embedded in resin. In this article, we introduce our related SEM techniques that use SE and BSE signals, such as the osmium maceration method, semithin section SEM (section-face imaging of resin-embedded semithin sections), section-face imaging for correlative light and SEM, and serial section SEM, to summarize their applications to neural structure and discuss the future possibilities and directions for these methods.


Animals ◽  
2021 ◽  
Vol 11 (12) ◽  
pp. 3390
Author(s):  
Bogdan Lewczuk ◽  
Natalia Szyryńska

The development of field-emission scanning electron microscopes for high-resolution imaging at very low acceleration voltages and equipped with highly sensitive detectors of backscattered electrons (BSE) has enabled transmission electron microscopy (TEM)-like imaging of the cut surfaces of tissue blocks, which are impermeable to the electron beam, or tissue sections mounted on the solid substrates. This has resulted in the development of methods that simplify and accelerate ultrastructural studies of large areas and volumes of biological samples. This article provides an overview of these methods, including their advantages and disadvantages. The imaging of large sample areas can be performed using two methods based on the detection of transmitted electrons or BSE. Effective imaging using BSE requires special fixation and en bloc contrasting of samples. BSE imaging has resulted in the development of volume imaging techniques, including array tomography (AT) and serial block-face imaging (SBF-SEM). In AT, serial ultrathin sections are collected manually on a solid substrate such as a glass and silicon wafer or automatically on a tape using a special ultramicrotome. The imaging of serial sections is used to obtain three-dimensional (3D) information. SBF-SEM is based on removing the top layer of a resin-embedded sample using an ultramicrotome inside the SEM specimen chamber and then imaging the exposed surface with a BSE detector. The steps of cutting and imaging the resin block are repeated hundreds or thousands of times to obtain a z-stack for 3D analyses.


2021 ◽  
Author(s):  
Tyler S Saunders ◽  
Amanda Heslegrave ◽  
Declan King ◽  
Sarah Harris ◽  
Craig W Ritchie ◽  
...  

INTRODUCTION: Plasma phospho-tau 181 (p-tau181) is a promising blood biomarker for Alzheimer's disease. However, its predictive validity for age-related cognitive decline without dementia remains unclear. Several forms of p-tau have been shown to contribute to synapse degeneration, but it is unknown whether p-tau181 is present in synapses. Here, we tested whether plasma p-tau181predicts cognitive decline and whether it is present in synapses in human brain. METHODS: General cognitive ability and plasma p-tau181 concentration were measured in 195 participants at ages 72 and 82. Levels of p-tau181 in total homogenate and synaptic fractions were compared with western blot (n=10-12 per group), and synaptic localisation was examined using array tomography. RESULTS: Elevated baseline plasma p-tau181 and increasing p-tau181 over time predicted steeper general cognitive decline. We observe p-tau181 in neurites, presynapses, and post-synapses in the brain. DISCUSSION: Baseline and subsequent change in plasma p-tau181 may represent rare biomarkers of differences in cognitive ageing across the 8th decade of life and may play a role in synaptic function in the brain.


2021 ◽  
Author(s):  
Gayathri Mahalingam ◽  
Russel Torres ◽  
Daniel Kapner ◽  
Eric T Trautman ◽  
Tim Fliss ◽  
...  

Serial section Electron Microscopy can produce high throughput imaging of large biological specimen volumes. The high-resolution images are necessary to reconstruct dense neural wiring diagrams in the brain, so called connectomes. A high fidelity volume assembly is required to correctly reconstruct neural anatomy and synaptic connections. It involves seamless 2D stitching of the images within a serial section followed by 3D alignment of the stitched sections. The high throughput of ssEM necessitates 2D stitching to be done at the pace of imaging, which currently produces tens of terabytes per day. To achieve this, we present a modular volume assembly software pipeline ASAP(Assembly Stitching and Alignment Pipeline) that is scalable and parallelized to work with distributed systems. The pipeline is built on top of the Render [18] services used in the volume assembly of the brain of adult Drosophila melanogaster [2]. It achieves high throughput by operating on the meta-data and transformations of each image stored in a database, thus eliminating the need to render intermediate output. The modularity of ASAP allows for easy adaptation to new algorithms without significant changes to the workflow. The software pipeline includes a complete set of tools to do stitching, automated quality control, 3D section alignment, and rendering of the assembled volume to disk. We also implemented a workflow engine that executes the volume assembly workflow in an automated fashion triggered following the transfer of raw data. ASAP has been successfully utilized for continuous processing of several large-scale datasets of the mouse visual cortex and human brain samples including one cubic millimeter of mouse visual cortex [1, 25]. The pipeline also has multi-channel processing capabilities and can be applied to fluorescence and multi-modal datasets like array tomography.


2021 ◽  
Vol 15 ◽  
Author(s):  
Gyeong Tae Kim ◽  
Sangkyu Bahn ◽  
Nari Kim ◽  
Joon Ho Choi ◽  
Jinseop S. Kim ◽  
...  

Critical determinants of synaptic functions include subcellular locations, input sources, and specific molecular characteristics. However, there is not yet a reliable and efficient method that can detect synapses. Electron microscopy is a gold-standard method to detect synapses due to its exceedingly high spatial resolution. However, it requires laborious and time-consuming sample preparation and lengthy imaging time with limited labeling methods. Recent advances in various fluorescence microscopy methods have highlighted fluorescence microscopy as a substitute for electron microscopy in reliable synapse detection in a large volume of neural circuits. In particular, array tomography has been verified as a useful tool for neural circuit reconstruction. To further improve array tomography, we developed a novel imaging method, called “structured illumination microscopy on the putative region of interest on ultrathin sections”, which enables efficient and accurate detection of synapses-of-interest. Briefly, based on low-magnification conventional fluorescence microscopy images, synapse candidacy was determined. Subsequently, the coordinates of the regions with candidate synapses were imaged using super-resolution structured illumination microscopy. Using this system, synapses from the high-order thalamic nucleus, the posterior medial nucleus in the barrel cortex were rapidly and accurately imaged.


2021 ◽  
Vol 15 ◽  
Author(s):  
Martina Schifferer ◽  
Nicolas Snaidero ◽  
Minou Djannatian ◽  
Martin Kerschensteiner ◽  
Thomas Misgeld

Ultrastructural analysis of discrete neurobiological structures by volume scanning electron microscopy (SEM) often constitutes a “needle-in-the-haystack” problem and therefore relies on sophisticated search strategies. The appropriate SEM approach for a given relocation task not only depends on the desired final image quality but also on the complexity and required accuracy of the screening process. Block-face SEM techniques like Focused Ion Beam or serial block-face SEM are “one-shot” imaging runs by nature and, thus, require precise relocation prior to acquisition. In contrast, “multi-shot” approaches conserve the sectioned tissue through the collection of serial sections onto solid support and allow reimaging. These tissue libraries generated by Array Tomography or Automated Tape Collecting Ultramicrotomy can be screened at low resolution to target high resolution SEM. This is particularly useful if a structure of interest is rare or has been predetermined by correlated light microscopy, which can assign molecular, dynamic and functional information to an ultrastructure. As such approaches require bridging mm to nm scales, they rely on tissue trimming at different stages of sample processing. Relocation is facilitated by endogenous or exogenous landmarks that are visible by several imaging modalities, combined with appropriate registration strategies that allow overlaying images of various sources. Here, we discuss the opportunities of using multi-shot serial sectioning SEM approaches, as well as suitable trimming and registration techniques, to slim down the high-resolution imaging volume to the actual structure of interest and hence facilitate ambitious targeted volume SEM projects.


Author(s):  
Liao Caiyu ◽  
Megumi Nakamura ◽  
Miyuki Mayanagi ◽  
Atsuko Kayaba ◽  
Yasuyuki Sasano

2021 ◽  
Vol 29 (5) ◽  
pp. 34-39
Author(s):  
Connon I. Thomas ◽  
Nicolai T. Urban ◽  
Ye Sun ◽  
Lesley A. Colgan ◽  
Xun Tu ◽  
...  

Abstract:In correlative light and electron microscopy (CLEM) workflows, identifying the same sub-cellular features in tissue by both light (LM) and electron microscopy (EM) remains a challenge. Furthermore, use of cryo-fixation for EM is desirable to capture rapid biological phenomena. Here, we describe a workflow that incorporates cryo-confocal laser scanning microscopy into the CLEM process, mapping cells in brain slices to re-image them with serial section scanning electron microscopy (ssSEM) array tomography. The addition of Airyscan detection increased the signal-to-noise ratio (SNR), allowing individual spines in thick frozen tissue to be visualized at a sufficient spatial resolution, providing a new tool for a CLEM approach to capture biological dynamics.


BMC Biology ◽  
2021 ◽  
Vol 19 (1) ◽  
Author(s):  
Sergio Gabarre ◽  
Frank Vernaillen ◽  
Pieter Baatsen ◽  
Katlijn Vints ◽  
Christopher Cawthorne ◽  
...  

Abstract Background Array tomography (AT) is a high-resolution imaging method to resolve fine details at the organelle level and has the advantage that it can provide 3D volumes to show the tissue context. AT can be carried out in a correlative way, combing light and electron microscopy (LM, EM) techniques. However, the correlation between modalities can be a challenge and delineating specific regions of interest in consecutive sections can be time-consuming. Integrated light and electron microscopes (iLEMs) offer the possibility to provide well-correlated images and may pose an ideal solution for correlative AT. Here, we report a workflow to automate navigation between regions of interest. Results We use a targeted approach that allows imaging specific tissue features, like organelles, cell processes, and nuclei at different scales to enable fast, directly correlated in situ AT using an integrated light and electron microscope (iLEM-AT). Our workflow is based on the detection of section boundaries on an initial transmitted light acquisition that serves as a reference space to compensate for changes in shape between sections, and we apply a stepwise refinement of localizations as the magnification increases from LM to EM. With minimal user interaction, this enables autonomous and speedy acquisition of regions containing cells and cellular organelles of interest correlated across different magnifications for LM and EM modalities, providing a more efficient way to obtain 3D images. We provide a proof of concept of our approach and the developed software tools using both Golgi neuronal impregnation staining and fluorescently labeled protein condensates in cells. Conclusions Our method facilitates tracing and reconstructing cellular structures over multiple sections, is targeted at high resolution ILEMs, and can be integrated into existing devices, both commercial and custom-built systems.


Sign in / Sign up

Export Citation Format

Share Document