dynamic image analysis
Recently Published Documents


TOTAL DOCUMENTS

69
(FIVE YEARS 30)

H-INDEX

9
(FIVE YEARS 3)

Géotechnique ◽  
2021 ◽  
pp. 1-40
Author(s):  
Linzhu Li ◽  
Quan Sun ◽  
Magued Iskander

Two-dimensional Dynamic Image Analysis (DIA) is gaining acceptance in geotechnical engineering research. Three-dimensional (3D) DIA extracts features from 8-12 projections of a particles thus it is believed to verge on the true particle morphology. DIA is fast, efficient, and convenient for characterizing thousands of particles quickly; nevertheless, it captures shapes that are fundamentally different than the 3D morphologies reconstructed using micro-computed tomography (μCT).  In DIA particle features are interpreted using external images of a particle, which fail to account for differences in imaging perspectives. In addition, 2D and 3D shape descriptors are influenced by differences in dimensionality projection owing to variations in definition, dimensionality, and perspectives of the particle images employed which causes them to differ from their 3D counterparts.  In this study we compared sand particle size and shape descriptors obtained using both DIA and μCT for three natural sands having wide granulometries. 3D DIA offers significant advantages in terms of efficiency, while providing adequate representation of Feret dimensions, Sphericity and Convexity.  However, the study demonstrates that 3D Roundness is difficult to characterize using DIA and that shape measurements of complex irregular calcareous sands obtained from 3D DIA are not comparable to those obtained using μCT.


Pharmaceutics ◽  
2021 ◽  
Vol 13 (11) ◽  
pp. 1894
Author(s):  
Oliver Macho ◽  
Ľudmila Gabrišová ◽  
Peter Peciar ◽  
Martin Juriga ◽  
Róbert Kubinec ◽  
...  

The aim of the work was to analyze the influence of process parameters of high shear granulation on the process yield and on the morphology of granules on the basis of dynamic image analysis. The amount of added granulation liquid had a significant effect on all monitored granulometric parameters and caused significant changes in the yield of the process. In regard of the shape, the most spherical granules with the smoothest surface were formed at a liquid to solid ratio of ≈1. The smallest granules were formed at an impeller speed of 700 rpm, but the granules formed at 500 rpm showed both the most desirable shape and the highest process yield. Variation in the shape factors relied not only on the process parameters, but also on the area equivalent diameter of the individual granules in the batch. A linear relationship was found between the amount of granulation liquid and the compressibility of the granules. Using response surface methodology, models for predicting the size of granules and process yield related to the amount of added liquid and the impeller speed were generated, on the basis of which the size of granules and yield can be determined with great accuracy.


2021 ◽  
Vol 608 ◽  
pp. 121110
Author(s):  
Oliver Macho ◽  
Ľudmila Gabrišová ◽  
Jana Brokešová ◽  
Petra Svačinová ◽  
Jitka Mužíková ◽  
...  

2021 ◽  
Vol 7 (2) ◽  
pp. 617-620
Author(s):  
Anja Kurzhals ◽  
Christoph Brandt-Wunderlich ◽  
Klaus-Peter Schmitz ◽  
Niels Grabow ◽  
Wolfram Schmidt

Abstract The assessment of particulate matter generated during a simulated use is requested by international standards for approval of cardiovascular devices. The particle suspension was generated during a simulated use test procedure of a commercially available coronary stent delivery system and analyzed by Dynamic image analysis (DIA) using FlowCAM 8000. Four parameters were analyzed: the diameter, the aspect ratio value, the circularity and the intensity. The results revealed that 53% of the particles were larger than 25 μm. The particle shapes were inhomogeneous with a wide ranging aspect ratio of 0.03 to 0.95. Around 83% had an intensity value of more than 140 grey scales and appeared translucent.


2021 ◽  
Vol 30 (9) ◽  
pp. 7019-7034
Author(s):  
Marco Mitterlehner ◽  
Herbert Danninger ◽  
Christian Gierl-Mayer ◽  
Harald Gschiel ◽  
Carlos Martinez ◽  
...  

AbstractIn recent years, the interest in additive manufacturing technologies has increased significantly, most of them using powders as feedstock material. It is therefore essential to check the quality of the powder before processing in order to ensure the same quality of the printed components at all times. This kind of quality assurance of a powder should be carried out independently of the additive manufacturing technology used. Since there is a lack of standards in this field, various powder analysis methods are available, with which, in principle, the same characteristics can often be measured, at least nominally. To verify the validity of these methods, three different nickel-based powders used for additive manufacturing were examined in the present study using standard methods (apparent density, tap density, Hall flow rate, optical microscopy, scanning electron microscopy) and advanced characterization methods (dynamic image analysis, x-ray microcomputed tomography, adsorption measurement by Brunauer–Emmett–Teller method). A special focus has been given on particle size distribution, particle shape, specific surface area, and internal porosity. The results of these measurements were statistically compared. This study therefore provides an insight into the advantages and disadvantages of various optical characterization techniques.


Geofluids ◽  
2021 ◽  
Vol 2021 ◽  
pp. 1-11
Author(s):  
Zhigang Zhang ◽  
Xiangyun Lan ◽  
Guangcai Wen ◽  
Qingming Long ◽  
Xuelin Yang

Particle size and shape distribution can be measured in great detail by dynamic image analysis (DIA). The narrow dispersion of repeated experiment results indicates that the particle size distribution can be obtained with high reliability. Particle size distribution can be better fitted to Rosin-Rammler equation than Gaudin-Schuhmann distribution and the lognormal distribution. The spread parameter ( m ) and the location parameters ( d 0 ) of the Rosin-Rammler equation can be calculated precisely. We analyzed the similarities and differences between the different particle shape distributions. The distributions of form factor and circularity are right-skewed distributions, while the distributions of ellipse ratio, irregularity, and aspect ratio obey a normal distribution. By studying the relation between particle size and shape, we find a linear relationship between the ellipse ratio and the Legendre ellipse diameter on the logarithmic scale.


Author(s):  
Airong Qian ◽  
Tzu-Bou Hsieh ◽  
M. Moazzem Hossain ◽  
Jim J.-C. Lin ◽  
J.-P. Jin

Calponin 2 is an actin cytoskeleton-associated protein and plays a role in regulating cell motility-related functions such as phagocytosis, migration and division. We previously reported that the expression of calponin 2 inhibits the rate of cell proliferation. To investigate the underlying mechanism, our present study found that the levels of endogenous calponin 2 in NIH3T3 and HEK293 cells rapidly decreased prior to cell division characterized by an absence at the actin contractile ring. In cells lacking endogenous calponin 2, transfective expression of GFP-fusion calponin 2 inhibited cell proliferation similar to that of non-fusion calponin 2. Fluorescent imaging studies of mitotic cells indicated that a proper level of calponin 2 expression and effective degradation during cytokinesis are necessary for normal cell division. Computer-assisted dynamic image analysis of dividing cells revealed that over-expression of calponin 2 significantly affects motile and shape behaviors of cells only on the interval from the start of anaphase to the start of cytokinesis, i.e., the pre-cytokinesis phase, but not on the interval from the start of cytokinesis to 50% completion of cytokinesis. The pre-cytokinesis degradation of calponin 2 was attenuated by MG132 inhibition of the ubiquitin proteasome and inhibitor of protein kinase C (PKC), suggesting that PKC phosphorylation-triggered degradation of calponin 2 could determine the rate of cytokinesis. The novel role of calponin 2 in regulating the rate of cytokinesis may be targeted for therapeutic applications such as in an inhibition of malignant tumor growth.


Author(s):  
John Seghers ◽  
Elzbieta A. Stefaniak ◽  
Rita La Spina ◽  
Claudia Cella ◽  
Dora Mehn ◽  
...  

AbstractValidation of analytical methods for measurements of microplastics (MP) is severely hampered because of a general lack of reference materials, RM. There is a great need to develop such reference materials. This study presents a concept of three-component kit with immobilised MP in solid NaCl, a surfactant and clean water that can be applied for the production of many types of MP RMs. As proof of concept, an RM for polyethylene terephthalate (PET) particles in water was prepared and evaluated for its homogeneity. The particles ranged from 30 μm (Feretmin) to about 200 μm adapted by wet sieving. A specific number of PET particles were immobilized in about 0.29 g of solid NaCl by freeze-drying 1 mL of a NaCl suspension. By using manual and automated counting, twenty reconstituted 1-L water samples were evaluated for homogeneity with respect to number of PET particles from 30 μm to > 200 μm/L of water. The number of particles was 730 ± 120 (mean ± one standard deviation (SD); n = 10) and 865 ± 155 particles (n = 10) obtained by optical microscopy in two independent laboratories. This corresponded to relative SDs of 16.4 and 17.9% and a mean of 797 ± 151 particles (18.9% RSD, for n = 20). Homogeneity studies of the NaCl carrier without reconstitution resulted in 794 ± 60 particles (7.5% RSD). The homogeneity of PET in the salt carrier was also evaluated directly with respect to mass of PET per vial using an ultra-micro balance. An average mass of 293 ± 41 μg of PET was obtained (14, % RSD for n = 14). Micrographs were recorded to demonstrate the absence of major sources of contamination of the RM components. Information about the particle size distribution and particle shapes was obtained by laser diffraction (LD) and dynamic image analysis (DIA). In addition, the identity of the PET polymer was confirmed by Raman and FT-IR spectroscopy. The RM was developed for a large-scale inter-laboratory comparison of PET particles in water (ILC). Based on the homogeneity results, the material was found to be sufficiently homogeneous to be of meaningful use in the ILC. In a 3-day process, more than 500 samples of PET particles in the NaCl carrier were prepared with good potential for further upscaling with respect to the number of vials or with other kinds of polymers. The stability of PET was not evaluated but it was deemed to be stable for the duration of the ILC.


Sign in / Sign up

Export Citation Format

Share Document