immersion type
Recently Published Documents


TOTAL DOCUMENTS

67
(FIVE YEARS 9)

H-INDEX

6
(FIVE YEARS 1)

2021 ◽  
Vol 3 ◽  
pp. 190-196
Author(s):  
Jiaqi Huang

In 2020, “Overall Scheme of Hainan Free Trade Port Construction” emphasized that Hainan should focus on developing modern service industry represented by medical and educational fields. In this context, the public health law education in Hainan, as a representative course integrating the dual characteristics of 'medical' and 'education', should also keep pace with the times to better meet the practical needs of the construction of Hainan free trade port. Through the extensive and in-depth investigation of five hospitals, two courts and five universities randomly selected in Hainan Province, and the analysis of 815 effective questionnaires collected by SPSS statistical method to form a survey database, the key and difficult points that need to be broken through in the innovation of Public Health Law education under the background of the construction of Hainan Free Trade Port are systematically summarized, and the scientific structure of strategic discipline orientation to improve the attention of Health Law, the adoption of immersion-type Health Law teaching methods.


Sensors ◽  
2021 ◽  
Vol 21 (10) ◽  
pp. 3371
Author(s):  
Ki-Chang Kang ◽  
Kwan-Kyu Park

We present a noncontact, non-immersion ultrasonic inspection method. A broadband ultrasound signal generated by a pulsed laser was measured using a hydrophone. The generated ultrasound signals propagated through the specimen and received a signal from the hydrophone in the water. Soldered chip ceramic capacitors, resistors, and surface-mount-type chip amplifiers were used as experimental specimens. A polydimethylsiloxane layer was used to prevent the specimen from being impacted by contact with water. The presence of a crack in the middle of the specimen resulted in an air layer, and the intermediate air layer reduced the magnitude of the signal transmitted owing to impedance mismatch. Using this principle, the cracks in each specimen could be distinguished. The image contrast ratio derived from the proposed method is approximately two to three times higher than that derived using the conventional immersion ultrasonic method. These results show that the proposed method can replace existing immersion-type ultrasound transmitted images.


Processes ◽  
2021 ◽  
Vol 9 (4) ◽  
pp. 683
Author(s):  
Kai-Shing Yang ◽  
Yun-Sheng Chao ◽  
Chia-Hsing Hsieh ◽  
Min-Lun Chai ◽  
Chi-Chuan Wang

This study examines the applicability of the ice storage systems in the small commercial refrigerated showcases through experimental analysis. R-404A is used as the working fluid and various influence of parameter settings and improvements, are discussed in details. In the ice storage system, the condenser is changed from air-cooling (refrigeration mode) to an immersion type that is placed in an ice storage tank, the corresponding condensing temperature and pressure are reduced appreciably. This increased the efficiency and can effectively reduce the peak power consumption. The reduction of the condensing temperature and pressure increased the coefficient of performance (COP) from 3.6 (refrigeration mode) to 6.35 (melting mode), effectively enhancing the refrigeration efficiency. The results indicated that the ice storage system could effectively increase the coefficient of performance from 3.6 to 6.35 during ice melting when compared to the conventional refrigeration system. It also can shift approximately 35% of the power during peak hours and lower the energy cost by USD$ 17.13 per month.


2020 ◽  
Vol 14 (5) ◽  
pp. 835-842
Author(s):  
Makoto Nikawa ◽  
Yu Iba ◽  
Minoru Yamashita ◽  
◽  

The aim of this study is to experimentally determine the solid fraction at the cessation of the flow of a molten Al-Si-Mg alloy (JIS-AC4CH) ceases. In this study, an experimental apparatus to measure the melt temperature during flow was developed and was used to perform highly accurate temperature measurements. An immersion-type optical-fiber radiation thermometer without emissivity correction was used for the temperature measurement device in this apparatus. The solid fraction was calculated from the area of primary crystals when the molten metal at any temperature was quenched. The melt temperature at flow cessation was higher than the eutectic reaction temperature, and the solid fraction in the melt front was approximately 0.2. However, the maximum solid fraction was found at a position slightly away from the melt front toward the pouring gate, and was approximately 0.3. It was inferred for this Al-Si-Mg alloy, that the flow cessation mechanism was a mixture of skin formation and mushy formation types.


Author(s):  
Weston L. Tew ◽  
Klaus N. Quelhas

The Minamata Convention on Mercury has created a near-term need to develop alternative fixed points to replace the mercury triple point (Hg TP) for calibration of standard platinum resistance thermometers (SPRTs) on the International Temperature Scale of 1990 (ITS-90). The sulfur hexafluoride (SF6) TP is a good candidate to provide adequate “drop-in compatible” replacements for the lowest costs. We report our first results of SF6 TP realizations performed at the National Institute of Standards and Technology (NIST) using a new series of transportable and refillable triple-point cells. The melting curves are presented at various melted fractions F and compared to evaluate the reproducibility and overall uncertainty for the realizations. We obtained a TP temperature of 223.55587(33) K at F = 50 % and 223.55607(35) K at F = 100 % as a weighted average of realizations using two adiabatic-type cells and two immersion-type cells. (Unless otherwise stated, uncertainties are standard uncertainties corresponding to a 68 % confidence level.) Temperatures were derived using a combination of five different SPRTs as calibrated at NIST on the ITS-90. The data were evaluated over a region of the melting plateau for melted fraction F between 30 % ≤ F ≤ 80 % with a 0.2 mK wide melting range. The results from the immersion-type cells were used to derive an experimental value for the SF6 TP static head correction of −11.6(1.7) mK/m. This value implies an initial slope of the pressure-temperature (p-T) equilibrium melting line of 1.55 MPa/K, whichis in agreement with the value predicted via the Clapeyron equation. The uncertainties of these initial SF6 TP realizations are limitedby uncertainty in the realization of the ITS-90 (0.25 mK) and, to a lesser extent, static pressure head effects and chemical impurities.


Sign in / Sign up

Export Citation Format

Share Document