Safety and imaging performance of two‐channel RF shimming for fetal MRI at 3T

Author(s):  
Filiz Yetisir ◽  
Esra Abaci Turk ◽  
Bastien Guerin ◽  
Borjan A. Gagoski ◽  
P. Ellen Grant ◽  
...  
Author(s):  
C J R Sheppard

The confocal microscope is now widely used in both biomedical and industrial applications for imaging, in three dimensions, objects with appreciable depth. There are now a range of different microscopes on the market, which have adopted a variety of different designs. The aim of this paper is to explore the effects on imaging performance of design parameters including the method of scanning, the type of detector, and the size and shape of the confocal aperture.It is becoming apparent that there is no such thing as an ideal confocal microscope: all systems have limitations and the best compromise depends on what the microscope is used for and how it is used. The most important compromise at present is between image quality and speed of scanning, which is particularly apparent when imaging with very weak signals. If great speed is not of importance, then the fundamental limitation for fluorescence imaging is the detection of sufficient numbers of photons before the fluorochrome bleaches.


Author(s):  
R.P. Ferrier ◽  
S. McVitie

Type II magnetic contrast was first observed by Philibert and Tixier and relies on the change in the effective backscattering coefficient due to interaction of the scattered electrons within the specimen and the local magnetic induction (for a review see Tsuno). Depending on the tilt of the specimen and the position of the backscattered electron detector(s), contrast due to the presence of either or both domains and domain walls can be obtained; in the case of the latter, the standard geometry is for the specimen to be normal to the incident beam and the detectors are positioned above it and close to the optic axis. This is the geometry adopted in our studies, which used a JEOL 2000FX with a special split objective lens polepiece; this permitted the specimen to be in magnetic field-free space, the separate lens gaps above and below allowing good probe forming capabilities combined with excellent Lorentz imaging performance. A schematic diagram is shown in Fig. 1.


Author(s):  
H. Rose

The imaging performance of the light optical lens systems has reached such a degree of perfection that nowadays numerical apertures of about 1 can be utilized. Compared to this state of development the objective lenses of electron microscopes are rather poor allowing at most usable apertures somewhat smaller than 10-2 . This severe shortcoming is due to the unavoidable axial chromatic and spherical aberration of rotationally symmetric electron lenses employed so far in all electron microscopes.The resolution of such electron microscopes can only be improved by increasing the accelerating voltage which shortens the electron wave length. Unfortunately, this procedure is rather ineffective because the achievable gain in resolution is only proportional to λ1/4 for a fixed magnetic field strength determined by the magnetic saturation of the pole pieces. Moreover, increasing the acceleration voltage results in deleterious knock-on processes and in extreme difficulties to stabilize the high voltage. Last not least the cost increase exponentially with voltage.


PIERS Online ◽  
2005 ◽  
Vol 1 (5) ◽  
pp. 543-546
Author(s):  
Ho-Jin Lee ◽  
Hyuk Park ◽  
Sung-Hyun Kim ◽  
Yong-Hoon Kim

2006 ◽  
Vol 187 (2) ◽  
pp. W247-W247
Author(s):  
Robert C. McKinstry
Keyword(s):  

2010 ◽  
Vol 95 (Supplement 1) ◽  
pp. Fa28-Fa29
Author(s):  
I. Osman ◽  
K. Forbes ◽  
J. Brennand ◽  
A. Cameron ◽  
M. Ledingham
Keyword(s):  

Sign in / Sign up

Export Citation Format

Share Document