Preparation and performance of (Co, Mn) 3 O 4 spinel coating on Crofer alloy by composite electrodeposition and step‐heating thermal conversion

Author(s):  
Zhang‐Bo Ma ◽  
Yuan‐Shuo Zhang ◽  
Hao Zhang ◽  
Min‐Gang Zhang ◽  
Yong‐Tang Li ◽  
...  
1995 ◽  
Vol 413 ◽  
Author(s):  
M. Ferreira ◽  
O. Onitsuka ◽  
A. C. Fou ◽  
B. Hsieh ◽  
M. F. Rubner

ABSTRACTPPV based light emitting thin film devices were fabricated using a layer-by-layer deposition technique involving the alternate spontaneous adsorption of a PPV precursor polymer and either poly(styrene-4-sulfonate) (SPS) or poly(methacrylic acid) (PMA). It was demonstrated that the polyanion used to self-assemble the PPV precursor strongly influences the characteristics and performance of the resulting LEDs. Devices fabricated with PPV created in the presence of SPS exhibited symmetric I–V curves, low luminance levels and very high current densities while PPV/PMA devices exhibited luminance levels in the range of 10–60 cd/m2 and classical rectifying behavior. These dramatic differences are primarily due to a low level of p-type doping activated during the thermal conversion of PPV and/or during device operation that confers excellent hole carrier transport capabilities to the PPV/SPS combination. Fabrication of a multi-slab type heterostructure device comprised of a PPV/SPS block (hole transporting block) and a PPV/PMA block (emitting block) resulted in improved performance with luminance levels significantly higher than previously obtained for a single slab PPV/PMA device (typically > 100 cd/m2). It was also demonstrated that the presence of very thin (about 20–30 Å thick) insulating layers at the Al/polymer interface improves device efficiency by a factor of 2–4.


2020 ◽  
Vol 2 (3) ◽  
pp. 252-269
Author(s):  
Brian Gumino ◽  
Nicholas A. Pohlman ◽  
Jonathan Barnes ◽  
Paul Wever

Biomass cookstoves are used as a common source of heating and cooking in developing countries with most improved cookstove design focusing on developing efficiency in thermal conversion of fuels and safer operation than open flame fires. A top-lit-up-draft (TLUD) cookstove utilizes a gasification process similar to pyrolysis where the solid biomass fuels are heated within a oxygen-limited environment and the syngas are burned which reduces carbon content and particulate matter being introduced into the air. The new continuous-operation design is described to have features for: (1) safe addition of solid fuels during combustion of syngas, (2) removal of biochar at the primary air inlet to manage gasification location, and (3) temperature control of the cooksurface through adjustable exhaust paths. The designed cookstove is found to have a diameter to height ratio 0.42-0.47 in order to offer the cleanest burning of the biofuel. The cooking surface is experimentally studied and the thermal gradient is found for compressed wood pellets. Tracking of the coal-bed is studied as a function of time in order to better understand when additional fuel should be added to ensure constant cooking temperature and operation. Numerous exhaust paths explore the cookstove user’s ability to control the temperature contour of the cooksurface.


Author(s):  
H. M. Thieringer

It has repeatedly been show that with conventional electron microscopes very fine electron probes can be produced, therefore allowing various micro-techniques such as micro recording, X-ray microanalysis and convergent beam diffraction. In this paper the function and performance of an SIEMENS ELMISKOP 101 used as a scanning transmission microscope (STEM) is described. This mode of operation has some advantages over the conventional transmission microscopy (CTEM) especially for the observation of thick specimen, in spite of somewhat longer image recording times.Fig.1 shows schematically the ray path and the additional electronics of an ELMISKOP 101 working as a STEM. With a point-cathode, and using condensor I and the objective lens as a demagnifying system, an electron probe with a half-width ob about 25 Å and a typical current of 5.10-11 amp at 100 kV can be obtained in the back focal plane of the objective lens.


Author(s):  
Huang Min ◽  
P.S. Flora ◽  
C.J. Harland ◽  
J.A. Venables

A cylindrical mirror analyser (CMA) has been built with a parallel recording detection system. It is being used for angular resolved electron spectroscopy (ARES) within a SEM. The CMA has been optimised for imaging applications; the inner cylinder contains a magnetically focused and scanned, 30kV, SEM electron-optical column. The CMA has a large inner radius (50.8mm) and a large collection solid angle (Ω > 1sterad). An energy resolution (ΔE/E) of 1-2% has been achieved. The design and performance of the combination SEM/CMA instrument has been described previously and the CMA and detector system has been used for low voltage electron spectroscopy. Here we discuss the use of the CMA for ARES and present some preliminary results.The CMA has been designed for an axis-to-ring focus and uses an annular type detector. This detector consists of a channel-plate/YAG/mirror assembly which is optically coupled to either a photomultiplier for spectroscopy or a TV camera for parallel detection.


Author(s):  
Joe A. Mascorro ◽  
Gerald S. Kirby

Embedding media based upon an epoxy resin of choice and the acid anhydrides dodecenyl succinic anhydride (DDSA), nadic methyl anhydride (NMA), and catalyzed by the tertiary amine 2,4,6-Tri(dimethylaminomethyl) phenol (DMP-30) are widely used in biological electron microscopy. These media possess a viscosity character that can impair tissue infiltration, particularly if original Epon 812 is utilized as the base resin. Other resins that are considerably less viscous than Epon 812 now are available as replacements. Likewise, nonenyl succinic anhydride (NSA) and dimethylaminoethanol (DMAE) are more fluid than their counterparts DDSA and DMP- 30 commonly used in earlier formulations. This work utilizes novel epoxy and anhydride combinations in order to produce embedding media with desirable flow rate and viscosity parameters that, in turn, would allow the medium to optimally infiltrate tissues. Specifically, embeding media based on EmBed 812 or LX 112 with NSA (in place of DDSA) and DMAE (replacing DMP-30), with NMA remaining constant, are formulated and offered as alternatives for routine biological work.Individual epoxy resins (Table I) or complete embedding media (Tables II-III) were tested for flow rate and viscosity. The novel media were further examined for their ability to infilftrate tissues, polymerize, sectioning and staining character, as well as strength and stability to the electron beam and column vacuum. For physical comparisons, a volume (9 ml) of either resin or media was aspirated into a capillary viscocimeter oriented vertically. The material was then allowed to flow out freely under the influence of gravity and the flow time necessary for the volume to exit was recored (Col B,C; Tables). In addition, the volume flow rate (ml flowing/second; Col D, Tables) was measured. Viscosity (n) could then be determined by using the Hagen-Poiseville relation for laminar flow, n = c.p/Q, where c = a geometric constant from an instrument calibration with water, p = mass density, and Q = volume flow rate. Mass weight and density of the materials were determined as well (Col F,G; Tables). Infiltration schedules utilized were short (1/2 hr 1:1, 3 hrs full resin), intermediate (1/2 hr 1:1, 6 hrs full resin) , or long (1/2 hr 1:1, 6 hrs full resin) in total time. Polymerization schedules ranging from 15 hrs (overnight) through 24, 36, or 48 hrs were tested. Sections demonstrating gold interference colors were collected on unsupported 200- 300 mesh grids and stained sequentially with uranyl acetate and lead citrate.


Author(s):  
D. E. Newbury ◽  
R. D. Leapman

Trace constituents, which can be very loosely defined as those present at concentration levels below 1 percent, often exert influence on structure, properties, and performance far greater than what might be estimated from their proportion alone. Defining the role of trace constituents in the microstructure, or indeed even determining their location, makes great demands on the available array of microanalytical tools. These demands become increasingly more challenging as the dimensions of the volume element to be probed become smaller. For example, a cubic volume element of silicon with an edge dimension of 1 micrometer contains approximately 5×1010 atoms. High performance secondary ion mass spectrometry (SIMS) can be used to measure trace constituents to levels of hundreds of parts per billion from such a volume element (e. g., detection of at least 100 atoms to give 10% reproducibility with an overall detection efficiency of 1%, considering ionization, transmission, and counting).


1986 ◽  
Vol 50 (5) ◽  
pp. 264-267 ◽  
Author(s):  
GH Westerman ◽  
TG Grandy ◽  
JV Lupo ◽  
RE Mitchell

2008 ◽  
Vol 17 (3) ◽  
pp. 87-92
Author(s):  
Leonard L. LaPointe

Abstract Loss of implicit linguistic competence assumes a loss of linguistic rules, necessary linguistic computations, or representations. In aphasia, the inherent neurological damage is frequently assumed by some to be a loss of implicit linguistic competence that has damaged or wiped out neural centers or pathways that are necessary for maintenance of the language rules and representations needed to communicate. Not everyone agrees with this view of language use in aphasia. The measurement of implicit language competence, although apparently necessary and satisfying for theoretic linguistics, is complexly interwoven with performance factors. Transience, stimulability, and variability in aphasia language use provide evidence for an access deficit model that supports performance loss. Advances in understanding linguistic competence and performance may be informed by careful study of bilingual language acquisition and loss, the language of savants, the language of feral children, and advances in neuroimaging. Social models of aphasia treatment, coupled with an access deficit view of aphasia, can salve our restless minds and allow pursuit of maximum interactive communication goals even without a comfortable explanation of implicit linguistic competence in aphasia.


Sign in / Sign up

Export Citation Format

Share Document