Model Study on the Application of Bamboo in Building Envelope

Author(s):  
Zujian Huang
2014 ◽  
Vol 35 (3) ◽  
pp. 144-157 ◽  
Author(s):  
Martin Bäckström ◽  
Fredrik Björklund

The difference between evaluatively loaded and evaluatively neutralized five-factor inventory items was used to create new variables, one for each factor in the five-factor model. Study 1 showed that these variables can be represented in terms of a general evaluative factor which is related to social desirability measures and indicated that the factor may equally well be represented as separate from the Big Five as superordinate to them. Study 2 revealed an evaluative factor in self-ratings and peer ratings of the Big Five, but the evaluative factor in self-reports did not correlate with such a factor in ratings by peers. In Study 3 the evaluative factor contributed above the Big Five in predicting work performance, indicating a substance component. The results are discussed in relation to measurement issues and self-serving biases.


2020 ◽  
pp. 50-64
Author(s):  
Kuladeep Kumar Sadevi ◽  
Avlokita Agrawal

With the rise in awareness of energy efficient buildings and adoption of mandatory energy conservation codes across the globe, significant change is being observed in the way the buildings are designed. With the launch of Energy Conservation Building Code (ECBC) in India, climate responsive designs and passive cooling techniques are being explored increasingly in building designs. Of all the building envelope components, roof surface has been identified as the most significant with respect to the heat gain due to the incident solar radiation on buildings, especially in tropical climatic conditions. Since ECBC specifies stringent U-Values for roof assembly, use of insulating materials is becoming popular. Along with insulation, the shading of the roof is also observed to be an important strategy for improving thermal performance of the building, especially in Warm and humid climatic conditions. This study intends to assess the impact of roof shading on building’s energy performance in comparison to that of exposed roof with insulation. A typical office building with specific geometry and schedules has been identified as base case model for this study. This building is simulated using energy modelling software ‘Design Builder’ with base case parameters as prescribed in ECBC. Further, the same building has been simulated parametrically adjusting the amount of roof insulation and roof shading simultaneously. The overall energy consumption and the envelope performance of the top floor are extracted for analysis. The results indicate that the roof shading is an effective passive cooling strategy for both naturally ventilated and air conditioned buildings in Warm and humid climates of India. It is also observed that a fully shaded roof outperforms the insulated roof as per ECBC prescription. Provision of shading over roof reduces the annual energy consumption of building in case of both insulated and uninsulated roofs. However, the impact is higher for uninsulated roofs (U-Value of 3.933 W/m2K), being 4.18% as compared to 0.59% for insulated roofs (U-Value of 0.33 W/m2K).While the general assumption is that roof insulation helps in reducing the energy consumption in tropical buildings, it is observed to be the other way when insulation is provided with roof shading. It is due to restricted heat loss during night.


2019 ◽  
pp. 10-15
Author(s):  
I.L. SHUBIN ◽  
◽  
N.P. UMNYAKOVA ◽  
I.V. MATVEEVA ◽  
K.A. ANDRIANOV ◽  
...  

Sign in / Sign up

Export Citation Format

Share Document