Test-retest reliability and concurrent validity of the Morrow Assessment of Nausea and Emesis (MANE) for the assessment of cancer chemotherapy-related nausea and vomiting

1988 ◽  
Vol 10 (2) ◽  
pp. 107-116 ◽  
Author(s):  
C. L. M. Carnrike ◽  
Phillip J. Brantley ◽  
Barbara Bruce ◽  
Shaista Faruqui ◽  
Frank M. Gresham ◽  
...  
2021 ◽  
Vol 21 (1) ◽  
Author(s):  
Widjane Sheila Ferreira Goncalves ◽  
Rebecca Byrne ◽  
Pedro Israel Cabral de Lira ◽  
Marcelo Tavares Viana ◽  
Stewart G. Trost

Abstract Background Childhood obesity has increased remarkably in low and middle-income (LMIC) countries. Movement behaviors (physical activity, screen time, and sleep) are crucial in the development of overweight and obesity in young children. Yet, few studies have investigated the relationship between children’s movement behaviors and parenting practices because validated measures for use among families from LMIC are lacking. This study evaluated the psychometric properties of previously validated measures of young children’s physical activity, screen time, and sleep and parenting practices, translated and culturally adapted to Brazilian families. Methods A total of 78 parent-child dyads completed an interviewer-administered survey twice within 7 days. Child physical activity, sedentary time and sleep were concurrently measured using a wrist-worn accelerometer. Internal consistency and test-retest reliability was assessed using McDonald’s Omega and Intraclass Correlation Coefficients (ICC’s). Concurrent validity was evaluated by calculating Spearman correlations between parent reported child behaviors and accelerometer measured behaviors. Results Seventeen of the 19 parenting practices scales exhibited acceptable internal consistency reliability (Ω ≥ 0.70). Test-retest reliability ICC’s were acceptable and ranged from 0.82 - 0.99. Parent reported child physical activity was positively correlated with objectively measured total movement (rho= 0.29 - 0.46, p < .05) and energetic play (rho= 0.29 – 0.40, p < .05). Parent reported child screen time was positively correlated with objectively measured sedentary time; (rho = 0.26, p < .05), and inversely correlated with total movement (rho = - 0.39 – - 0.41, p < .05) and energetic play (rho = - 0.37 – - 0.41, p < .05). Parent reported night-time sleep duration was significantly correlated with accelerometer measured sleep duration on weekdays (rho = 0.29, p < .05), but not weekends. Conclusions Measurement tools to assess children’s movement behaviors and parenting practices, translated and culturally adapted for use in Brazilian families, exhibited acceptable evidence of concurrent validity, internal consistency, and test-retest reliability.


Scientifica ◽  
2017 ◽  
Vol 2017 ◽  
pp. 1-6 ◽  
Author(s):  
Mostafa Sadeghi ◽  
Homayoun Sadeghi-Bazargani ◽  
Shahrokh Amiri

Background. The Barkley Adult Attention Deficit/Hyperactivity Disorder (ADHD) Rating Scale-IV (BAARS-IV) was developed, and it demonstrated good psychometric properties. The BAARS-IV includes 27 questions on the symptoms of adult ADHD. The purpose of the present study is to investigate the psychometric testing of the Persian version of BAARS-IV among the elderlies in Tabriz City. Method. This cross-sectional study was conducted in Tabriz City—in the west of Iran—in 2015 via enrolling of 121 old-aged people. We did the process of translation and adaptation of BAARS-IV and examined its concurrent validity, internal consistency, and test-retest reliability. Result. The BAARS-IV demonstrated good internal consistency and test-retest reliability. Correlations between the BAARS-IV and the CAARS-S: SV were high and evidence supporting concurrent validity was revealed. Cronbach’s alpha for the overall scale and subscales stood at 0.89, 0.81, 0.66, 0.56, and 0.82, respectively. Conclusion. The Persian BAARS-IV showed acceptable reliability and validity. BAARS-IV was determined to be composed of internally consistent and psychometrically sound items.


2021 ◽  
Vol 21 (S1) ◽  
Author(s):  
Pongrác Ács ◽  
Réka Veress ◽  
Paulo Rocha ◽  
Tamás Dóczi ◽  
Bence László Raposa ◽  
...  

Abstract Background Physical inactivity is a global phenomenon in European welfare countries. Proper monitoring is essential to measure the physical activity level of the population. Methods In the Hungarian cohort of the European Physical Activity and Sport Monitoring System (EUPASMOS) project, our participants (N = 598) completed sociodemographic questions and the International Physical Activity Questionnaire – short form (IPAQ-SF) survey. The validity and reliability of the subjective measurement tool were examined, IPAQ-SF outcomes were contrasted against triaxial RM42 accelerometer wore for 7 consecutive days. Results The IPAQ-SF showed moderate internal consistency (Cronbach Alpha = 0.647). The concurrent validity of the IPAQ-SF to triaxial accelerometer indicated a significant weak-to-moderate correlation (R = 0.111–0.338, p = 0.042; p < 0.001). The test-retest reliability showed a significant correlation between two measurements (R = 0.788–0.981, p < 0.001). Conclusion The Hungarian version of the IPAQ-SF had excellent test-retest reliability, but low-to-fair concurrent validity for moderate and vigorous physical activity, walking and sitting time, as compared to the objective criterion measure among Hungarian adults.


2021 ◽  
Vol 12 ◽  
Author(s):  
Wei Xia ◽  
William Ho Cheung Li ◽  
Tingna Liang ◽  
Yuanhui Luo ◽  
Laurie Long Kwan Ho ◽  
...  

Objectives: This study conducted a linguistic and psychometric evaluation of the Chinese Counseling Competencies Scale-Revised (CCS-R).Methods: The Chinese CCS-R was created from the original English version using a standard forward-backward translation process. The psychometric properties of the Chinese CCS-R were examined in a cohort of 208 counselors-in-training by two independent raters. Fifty-three counselors-in-training were asked to undergo another counseling performance evaluation for the test-retest. The confirmatory factor analysis (CFA) was conducted for the Chinese CCS-R, followed by internal consistency, test-retest reliability, inter-rater reliability, convergent validity, and concurrent validity.Results: The results of the CFA supported the factorial validity of the Chinese CCS-R, with adequate construct replicability. The scale had a McDonald's omega of 0.876, and intraclass correlation coefficients of 0.63 and 0.90 for test-retest reliability and inter-rater reliability, respectively. Significantly positive correlations were observed between the Chinese CCS-R score and scores of performance checklist (Pearson's γ = 0.781), indicating a large convergent validity, and knowledge on drug abuse (Pearson's γ = 0.833), indicating a moderate concurrent validity.Conclusion: The results support that the Chinese CCS-R is a valid and reliable measure of the counseling competencies.Practice implication: The CCS-R provides trainers with a reliable tool to evaluate counseling students' competencies and to facilitate discussions with trainees about their areas for growth.


2019 ◽  
pp. 174-180
Author(s):  
Fatemeh Sadat Bateni ◽  
Maryam Rahmatian ◽  
Ahmad Kaviani ◽  
Sebastian Simard ◽  
Mehdi Soleimani ◽  
...  

Background: This study aimed to translate and validate the Fear of Cancer Recurrence Inventory (FCRI) questionnaire into Persian and to investigate its psychometric properties. Methods: The FCRI was translated to Persian using a linguistic methodology according to WHO guidelines. A total of 450 breast cancer survivors who had the following inclusion criteria were included: time elapse of more than six months after the treatment prior to the study; absence ofobjective markers of recurrence, fluency in the Persian language, and signing the informed consent. Internal consistency was estimated with Cronbach's α coefficient and test-retest reliability with Interclass correlation.  Concurrent validity was estimated through Pearson’s correlation between the FCRI and Hospital Anxiety and Depression Scale (HADS). Principal component analysis (PCA) and confirmatory factor analysis (CFA) were employed to evaluate dimensionality. Results: The Persian version was acceptable for patients. The content validity index (CVI) was 0.80.  The instrument had good test-retest reliability (ICC= 0.96) and internal consistency (Cronbach’s α=0.86).  PCA and CFA indicated that the factor structure of the Persian version was similar to the original questionnaire and had acceptable goodness of fit.  Correlations between the FCRI and HADS was remarkable (r= 0.252 – 0.639), indicating acceptable concurrent validity. Conclusions: The Persian version of FCRI could be considered a good cross-cultural equivalent for the original English version. The questionnaire was a reliable and valid instrument in terms of internal consistency, test-retest reliability, and dimensionality.


2020 ◽  
pp. 073428292097071
Author(s):  
Michal Jabůrek ◽  
Adam Ťápal ◽  
Šárka Portešová ◽  
Steven I. Pfeiffer

The factor structure, the concurrent validity, and test–retest reliability of the Czech translation of the Gifted Rating Scales-School Form [GRS-S; Pfeiffer, S. I., & Jarosewich, T. (2003). GRS (gifted rating scales) - manual. Pearson] were evaluated. Ten alternative models were tested. Four models were found to exhibit acceptable fit and interpretability. The factor structure was comparable for both parent ( n = 277) and teacher raters ( n = 137). High correlations between the factors suggest that raters might be subject to a halo effect. Ratings made by teachers show a closer relationship with criteria (WJ IE II COG, CFT 20-R, and TIM3–5) than ratings made by parents. Test–retest reliability of teacher rating (with median 93 days) was quite high for all GRS-S subscales ( r = .84–.87).


2020 ◽  
Vol 34 (8) ◽  
pp. 1112-1121
Author(s):  
Jing Wang ◽  
Haibo Di ◽  
Wen Hua ◽  
Liwen Cheng ◽  
Zhigang Xia ◽  
...  

Objective: The aim of the study was to check on the reliability and validity of the translated version of Nociception Coma Scale–Revised. Design: Prospective psychometric study. Setting: Rehabilitation and neurology unit in hospital. Subjects: Patients with prolonged disorders of consciousness. Interventions: None. Main measures: The original English version of the Nociception Coma Scale–Revised was translated into Chinese. The reliability and validity were undertaken by trained raters. Intraclass correlation coefficients were used to assess inter-rater reliability and test–retest reliability. Cronbach’s alpha test was used to investigate internal consistency. Spearman’s correlation was used to calculate concurrent validity. The Coma Recovery Scale–revised was used to assess the consciousness of patients. Results: Eighty-four patients were enrolled in the study. Inter-rater reliability of the Chinese version of Nociception Coma Scale–Revised was high for total scores and motor and verbal subscores and good for facial subscores. Test–retest reliability was high for total score and for all subscores. Analysis revealed a moderate internal consistency for subscores. For the concurrent validity, a strong correlation was found between the Nociception Coma Scale–Revised and the Face, Legs, Activity, Cry, and Consolability behavioral scale for all patients. A moderate correlation was found between the Nociception Coma Scale–Revised and the Coma Recovery Scale–revised scores for all patients. Conclusion: The Chinese version of Nociception Coma Scale–Revised has good reliability and validity data for assessing responses to pain in patients with prolonged disorders of consciousness.


2000 ◽  
Vol 9 (1) ◽  
pp. 45-55 ◽  
Author(s):  
Giovanni De Girolamo ◽  
Paola Rucci ◽  
Paolo Scocco ◽  
Angela Becchi ◽  
Francesco Coppa ◽  
...  

SummaryObjective – To test the psychometric properties of the Italian version of the WHOQOL-BRIEF (e.g., construct and internal validity, concorrent validity with the MOS SF-36 and test-retest reliability). The WHOQOL-BRIEF is a 26-items self-report instrument which assesses four domains assumed to represent the Quality Of Life (QOL) construct: physical domain, psychological domain, social relationships domain and environment domain, plus two facets for assessing overall QOL and general health. Methods – Data have been collected in three sites (Bologna, Modena and Padua), located in the North of Italy, in the framework of the international WHOQOL project. According to the study design, the sample had to include about 50% males and 50% females, 50% of subjects below and 50% above the age of 45, all in contact with various health services. A subsample has been re-interviewed after 2-3 weeks in order to study test-retest reliability. After the WHOQOL-BRIEF, most subjects have also been administered the MOS-SF36 in order to test the concurrent validity between these two instruments. Results – The instrument was administered to 379 subjects (1/6 healthy and 1/6 sick), chosen to be representative of a variety of different medical conditions. Seventy patients, wTio displayed stable health conditions, have been reassessed after 2-3 weeks to study test-retest reliability. The WHOQOL-BRIEF domains has shown good internal consistency, ranging from 0.65 for the social relationships domain to 0.80 for the physical domain; it has been able to discriminate between in- and out-patients and between the two age groups considered in the present study (<45, ≥45 years). Only physical and psychological domains were found to discriminate between healthy and ill subjects. No gender differences in the mean scores for the four domains were found. Concurrent validity between the WHOQOL-Brief and the MOS-SF-36 was satisfactory, and specific for the physical and psychological health domains. Test-retest reliability values were also good, ranging from 0.76 for the environment domain to 0.93 for the psychological domain. Conclusions – This study shows that the WHOQOL-BRIEF is psychometrically valid and reliable, and that it is also potentially useful in discriminating between subjects with different health conditions in clinical settings.


Sensors ◽  
2019 ◽  
Vol 20 (1) ◽  
pp. 37 ◽  
Author(s):  
Christopher Buckley ◽  
M. Encarna Micó-Amigo ◽  
Michael Dunne-Willows ◽  
Alan Godfrey ◽  
Aodhán Hickey ◽  
...  

Asymmetry is a cardinal symptom of gait post-stroke that is targeted during rehabilitation. Technological developments have allowed accelerometers to be a feasible tool to provide digital gait variables. Many acceleration-derived variables are proposed to measure gait asymmetry. Despite a need for accurate calculation, no consensus exists for what is the most valid and reliable variable. Using an instrumented walkway (GaitRite) as the reference standard, this study compared the validity and reliability of multiple acceleration-derived asymmetry variables. Twenty-five post-stroke participants performed repeated walks over GaitRite whilst wearing a tri-axial accelerometer (Axivity AX3) on their lower back, on two occasions, one week apart. Harmonic ratio, autocorrelation, gait symmetry index, phase plots, acceleration, and jerk root mean square were calculated from the acceleration signals. Test–retest reliability was calculated, and concurrent validity was estimated by comparison with GaitRite. The strongest concurrent validity was obtained from step regularity from the vertical signal, which also recorded excellent test–retest reliability (Spearman’s rank correlation coefficients (rho) = 0.87 and Intraclass correlation coefficient (ICC21) = 0.98, respectively). Future research should test the responsiveness of this and other step asymmetry variables to quantify change during recovery and the effect of rehabilitative interventions for consideration as digital biomarkers to quantify gait asymmetry.


Sign in / Sign up

Export Citation Format

Share Document