scholarly journals Adaptation and Psychometric Evaluation of the Chinese Counseling Competencies Scale-Revised

2021 ◽  
Vol 12 ◽  
Author(s):  
Wei Xia ◽  
William Ho Cheung Li ◽  
Tingna Liang ◽  
Yuanhui Luo ◽  
Laurie Long Kwan Ho ◽  
...  

Objectives: This study conducted a linguistic and psychometric evaluation of the Chinese Counseling Competencies Scale-Revised (CCS-R).Methods: The Chinese CCS-R was created from the original English version using a standard forward-backward translation process. The psychometric properties of the Chinese CCS-R were examined in a cohort of 208 counselors-in-training by two independent raters. Fifty-three counselors-in-training were asked to undergo another counseling performance evaluation for the test-retest. The confirmatory factor analysis (CFA) was conducted for the Chinese CCS-R, followed by internal consistency, test-retest reliability, inter-rater reliability, convergent validity, and concurrent validity.Results: The results of the CFA supported the factorial validity of the Chinese CCS-R, with adequate construct replicability. The scale had a McDonald's omega of 0.876, and intraclass correlation coefficients of 0.63 and 0.90 for test-retest reliability and inter-rater reliability, respectively. Significantly positive correlations were observed between the Chinese CCS-R score and scores of performance checklist (Pearson's γ = 0.781), indicating a large convergent validity, and knowledge on drug abuse (Pearson's γ = 0.833), indicating a moderate concurrent validity.Conclusion: The results support that the Chinese CCS-R is a valid and reliable measure of the counseling competencies.Practice implication: The CCS-R provides trainers with a reliable tool to evaluate counseling students' competencies and to facilitate discussions with trainees about their areas for growth.

2013 ◽  
Vol 25 (9) ◽  
pp. 1503-1511 ◽  
Author(s):  
Florindo Stella ◽  
Orestes Vicente Forlenza ◽  
Jerson Laks ◽  
Larissa Pires de Andrade ◽  
Michelle A. Ljubetic Avendaño ◽  
...  

ABSTRACTBackground:Patients with dementia may be unable to describe their symptoms, and caregivers frequently suffer emotional burden that can interfere with judgment of the patient's behavior. The Neuropsychiatric Inventory-Clinician rating scale (NPI-C) was therefore developed as a comprehensive and versatile instrument to assess and accurately measure neuropsychiatric symptoms (NPS) in dementia, thereby using information from caregiver and patient interviews, and any other relevant available data. The present study is a follow-up to the original, cross-national NPI-C validation, evaluating the reliability and concurrent validity of the NPI-C in quantifying psychopathological symptoms in dementia in a large Brazilian cohort.Methods:Two blinded raters evaluated 312 participants (156 patient-knowledgeable informant dyads) using the NPI-C for a total of 624 observations in five Brazilian centers. Inter-rater reliability was determined through intraclass correlation coefficients for the NPI-C domains and the traditional NPI. Convergent validity included correlations of specific domains of the NPI-C with the Brief Psychiatric Rating Scale (BPRS), the Cohen-Mansfield Agitation Index (CMAI), the Cornell Scale for Depression in Dementia (CSDD), and the Apathy Inventory (AI).Results:Inter-rater reliability was strong for all NPI-C domains. There were high correlations between NPI-C/delusions and BPRS, NPI-C/apathy-indifference with the AI, NPI-C/depression-dysphoria with the CSDD, NPI-C/agitation with the CMAI, and NPI-C/aggression with the CMAI. There was moderate correlation between the NPI-C/aberrant vocalizations and CMAI and the NPI-C/hallucinations with the BPRS.Conclusion:The NPI-C is a comprehensive tool that provides accurate measurement of NPS in dementia with high concurrent validity and inter-rater reliability in the Brazilian setting. In addition to universal assessment, the NPI-C can be completed by individual domains.


2014 ◽  
Vol 114 (1) ◽  
pp. 93-103 ◽  
Author(s):  
Tomas Larson ◽  
Eva Norén Selinus ◽  
Clara Hellner Gumpert ◽  
Thomas Nilsson ◽  
Nóra Kerekes ◽  
...  

The Autism-Tics, AD/HD, and other Comorbidities (A–TAC) inventory is used in epidemiological research to assess neurodevelopmental problems and coexisting conditions. Although the A–TAC has been applied in various populations, data on retest reliability are limited. The objective of the present study was to present additional reliability data. The A–TAC was administered by lay assessors and was completed on two occasions by parents of 400 individual twins, with an average interval of 70 days between test sessions. Intra- and inter-rater reliability were analysed with intraclass correlations and Cohen's κ. A–TAC showed excellent test-retest intraclass correlations for both autism spectrum disorder and attention deficit hyperactivity disorder (each at .84). Most modules in the A–TAC had intra- and inter-rater reliability intraclass correlation coefficients of ≥ .60. Cohen's κ indicated acceptable reliability. The current study provides statistical evidence that the A–TAC yields good test-retest reliability in a population-based cohort of children.


2014 ◽  
Vol 94 (6) ◽  
pp. 866-874 ◽  
Author(s):  
Judit Takacs ◽  
S. Jayne Garland ◽  
Mark G. Carpenter ◽  
Michael A. Hunt

Background There is a high incidence of falls in older adults with knee osteoarthritis (OA). Adequate dynamic balance and mobility reduce the risk of falls; however, there are currently no validated, advanced tests of dynamic balance and mobility for individuals with knee OA. Objective The purpose of this study was to determine the convergent validity, known-groups validity, and test-retest reliability of a dynamic test of balance and mobility, the Community Balance and Mobility Scale (CB&M), in a knee OA population. Design A cross-sectional design was used. Methods Twenty-five individuals aged 50 years and older with medial knee OA and an equal number of healthy controls completed the CB&M and other tests of balance and mobility, including the Berg Balance Scale, the Timed “Up & Go” Test, a test of maximal single-leg stance time, and the 10-Meter Walk Test (self-selected and fast walking speed). Convergent validity of balance tests with the CB&M was assessed using Pearson product moment correlation coefficients, and known-groups validity was assessed using independent t tests. Test-retest reliability of the CB&M was assessed using intraclass correlation coefficients (ICCs) and standard error of measurement (SEM). Results Scores on the CB&M were significantly correlated with all measures of balance and mobility for those with knee OA. There were significant differences in CB&M scores between groups. Scores on the CB&M were highly reliable in people with knee OA (ICC=.95, 95% confidence interval [95% CI]=0.70 to 0.99; SEM=3, 95% CI=2.68 to 4.67). Limitations Few participants had severe knee OA. Conclusions The CB&M displayed moderate convergent validity, excellent known-groups validity, and high test-retest reliability. The CB&M can be used as a valid and reliable tool to assess dynamic balance and mobility deficits in people with knee OA.


2016 ◽  
Vol 4 ◽  
pp. 205031211665890 ◽  
Author(s):  
Kyra J Kane ◽  
Joel Lanovaz ◽  
Derek Bisaro ◽  
Alison Oates ◽  
Kristin E Musselman

Objective: Walking assessment is an important aspect of rehabilitation practice; yet, clinicians have few psychometrically sound options for evaluating walking in highly ambulatory children. The purpose of this study was to evaluate the validity and reliability of two new measures of walking function—the Obstacles and Curb tests—relative to the 10-Meter Walk test and Timed Up and Go test in children with spina bifida or cerebral palsy. Methods: A total of 16 ambulatory children with spina bifida ( n=9) or cerebral palsy ( n=7) (9 boys; mean age 7years, 7months; standard deviation 3years, 4months) and 16 age- and gender-matched typically developing children participated. Children completed the walking tests, at both self-selected and fast speeds, twice. To evaluate discriminative validity, scores were compared between typically developing and spina bifida/cerebral palsy groups. Within the spina bifida/cerebral palsy group, inter-test correlations evaluated convergent validity and intraclass correlation coefficients evaluated within-session test–retest reliability. Results: At fast speeds, all tests showed discriminative validity ( p<0.006 for typically developing and spina bifida/cerebral palsy comparisons) and convergent validity ( rho=0.81–0.90, p⩽0.001, for inter-test correlations). At self-selected speeds, only the Obstacles test discriminated between groups ( p=0.001). Moderately strong correlations ( rho=0.73–0.78, p⩽0.001) were seen between the 10-Meter Walk test, Curb test, and Timed Up and Go test. Intraclass correlation coefficients ranged from 0.81 to 0.97, with higher test–retest reliability for tests performed at fast speeds rather than self-selected speeds. Conclusion: The Obstacles and Curb tests are promising measures for assessing walking in this population. Performing tests at fast walking speeds may improve their validity and test–retest reliability for children with spina bifida/cerebral palsy.


2020 ◽  
Vol 63 (11) ◽  
pp. 3743-3759
Author(s):  
Mehdi Bakhtiar ◽  
Min Ney Wong ◽  
Emily Ka Yin Tsui ◽  
Malcolm R. McNeil

Purpose This study reports the psychometric development of the Cantonese versions of the English Computerized Revised Token Test (CRTT) for persons with aphasia (PWAs) and healthy controls (HCs). Method The English CRTT was translated into standard Chinese for the Reading–Word Fade version (CRTT-R- WF -Cantonese) and into formal Cantonese for the Listening version (CRTT-L-Cantonese). Thirty-two adult native Cantonese PWAs and 42 HCs were tested on both versions of CRTT-Cantonese tests and on the Cantonese Aphasia Battery to measure the construct and concurrent validity of CRTT-Cantonese tests. The HCs were retested on both versions of the CRTT-Cantonese tests, whereas the PWAs were randomly assigned for retesting on either version to measure the test–retest reliability. Results A two-way, Group × Modality, repeated-measures analysis of variance revealed significantly lower scores for the PWA group than the HC group for both reading and listening. Other comparisons were not significant. A high and significant correlation was found between the CRTT-R- WF -Cantonese and the CRTT-L-Cantonese in PWAs, and 87% of the PWAs showed nonsignificantly different performance across the CRTT-Cantonese tests based on the Revised Standardized Difference Test. The CRTT-R- WF -Cantonese provided better aphasia diagnostic sensitivity (100%) and specificity (83.30%) values than the CRTT-L-Cantonese. Pearson correlation coefficients revealed significant moderate correlations between the Cantonese Aphasia Battery scores and the CRTT-Cantonese tests in PWAs, supporting adequate concurrent validity. Intraclass correlation coefficient showed high test–retest reliability (between .82 and .96, p < .001) for both CRTT-Cantonese tests for both groups. Conclusions Results support that the validly translated CRTT-R- WF -Cantonese and CRTT-L-Cantonese tests significantly differentiate the reading and listening comprehension of PWAs from HCs and provides acceptable concurrent validity and high test–retest reliability for both tests. Furthermore, favorable PWA versus HC sensitivity and specificity cutoff scores are presented for both CRTT-Cantonese listening and reading tests.


2021 ◽  
pp. 135245852110181
Author(s):  
KH Lam ◽  
P van Oirschot ◽  
B den Teuling ◽  
HE Hulst ◽  
BA de Jong ◽  
...  

Background: Early detection and monitoring of cognitive dysfunction in multiple sclerosis (MS) may be enabled with smartphone-adapted tests that allow frequent measurements in the everyday environment. Objectives: The aim of this study was to determine the reliability, construct and concurrent validity of a smartphone-adapted Symbol Digit Modalities Test (sSDMT). Methods: During a 28-day follow-up, 102 patients with MS and 24 healthy controls (HC) used the MS sherpa® app to perform the sSDMT every 3 days on their own smartphone. Patients performed the Brief International Cognitive Assessment for MS at baseline. Test–retest reliability (intraclass correlation coefficients, ICC), construct validity (group analyses between cognitively impaired (CI), cognitively preserved (CP) and HC for differences) and concurrent validity (correlation coefficients) were assessed. Results: Patients with MS and HC completed an average of 23.2 ( SD = 10.0) and 18.3 ( SD = 10.2) sSDMT, respectively. sSDMT demonstrated high test–retest reliability (ICCs > 0.8) with a smallest detectable change of 7 points. sSDMT scores were different between CI patients, CP patients and HC (all ps < 0.05). sSDMT correlated modestly with the clinical SDMT (highest r = 0.690), verbal (highest r = 0.516) and visuospatial memory (highest r = 0.599). Conclusion: Self-administered smartphone-adapted SDMT scores were reliable and different between patients who were CI, CP and HC and demonstrated concurrent validity in assessing information processing speed.


2021 ◽  
Author(s):  
Qi Zhang ◽  
Ke Zhang ◽  
Miao Li ◽  
Jiaxin Gu ◽  
Xintong Li ◽  
...  

Abstract Objectives To examine the validity and reliability of the Mandarin version of the Treatment Burden Questionnaire (TBQ) among stroke patients. Background Stroke patients need long-term management of symptoms and life situation, and treatment burden has recently emerged as a new concept that can influence the health outcomes during the rehabilitation process. Methods The convenience sampling method was used to recruit 187 cases of stroke patients in a tertiary grade hospital in Tianjin for a formal investigation. Item analysis, reliability and validity tests were carried out. The reliability test included internal consistency and test–retest reliability. And as well as content, structure and convergent validity were performed for the validity test. Results Of the 187 completed questionnaires, only 180 (96.3%) were suitable for analysis. According to the experts’ evaluation, the I-CVI of each item was from 0.833 to 1.000, and the S-CVI was 0.967. The exploratory factor analysis yielded three-factor components with a cumulative variation of 53.054%. Convergent validity was demonstrated using measures of Morisky’s Medication Adherence Scale 8 (r = –0.450, P &lt; 0.01). All correlations between items and global scores ranged from 0.403 to 0.638. Internal consistency reliability and test–retest reliability were found to be acceptable, as indicated by a Cronbach’s α of 0.824 and an intraclass correlation coefficient of 0.846, respectively. Conclusions The Mandarin TBQ had acceptable validity and reliability. The use of TBQ in the assessment of treatment burden of stroke survivor may benefit health resources allocation and provide tailor therapeutic interventions to construct minimally disruptive care.


1997 ◽  
Vol 64 (5) ◽  
pp. 270-276 ◽  
Author(s):  
Johanne Desrosiers ◽  
Annie Rochette ◽  
Réjean Hébert ◽  
Gina Bravo

Several dexterity tests have been developed, including the Minnesota Rate of Manipulation Test (MRMT) and a new version, the Minnesota Manual Dexterity Test (MMDT). The objectives of the study were: a) to verify the test-retest reliability of the MMDT; b) to compare the MRMT and the MMDT; c) to study the concurrent validity of the MMDT; and d) to establish reference values for elderly people with the MMDT. Two hundred and forty-seven community-living healthy elderly were evaluated with the MMDT, and two other dexterity tests, the Box and Block Test (BBT) and the Purdue Pegboard (PP). Thirty-five of them were evaluated twice with the MMDT and 44 were evaluated with both the MMDT and MRMT. The results show that the test-retest reliability of the MMDT is acceptable to high (intraclass correlation coefficients of 0.79 to 0.87, depending on the subtest) and the validity of the test is demonstrated by significant correlations between the MMDT, the BBT and the PP (0.63 to 0.67). There is a high correlation (0.85 to 0.95) between the MMDT and the MMRT in spite of different results. The reference values will help occupational therapists to differentiate better between real dexterity difficulties and those that may be attributed to normal aging.


2008 ◽  
Vol 22 (6) ◽  
pp. 737-744 ◽  
Author(s):  
I-Ping Hsueh ◽  
Miao-Ju Hsu ◽  
Ching-Fan Sheu ◽  
Su Lee ◽  
Ching-Lin Hsieh ◽  
...  

Objective. To provide empirical justification for selecting motor scales for stroke patients, the authors compared the psychometric properties (validity, responsiveness, test-retest reliability, and smallest real difference [SRD]) of the Fugl-Meyer Motor Scale (FM), the simplified FM (S-FM), the Stroke Rehabilitation Assessment of Movement instrument (STREAM), and the simplified STREAM (S-STREAM). Methods. For the validity and responsiveness study, 50 inpatients were assessed with the FM and the STREAM at admission and discharge to a rehabilitation department. The scores of the S-FM and the S-STREAM were retrieved from their corresponding scales. For the test-retest reliability study, a therapist administered both scales on a different sample of 60 chronic patients on 2 occasions. Results. Only the S-STREAM had no notable floor or ceiling effects at admission and discharge. The 4 motor scales had good concurrent validity (rho ≥ .91) and satisfactory predictive validity (rho = .72-.77). The scales showed responsiveness (effect size d ≥ 0.34; standardized response mean ≥ 0.95; P < .0001), with the S-STREAM most responsive. The test-retest agreements of the scales were excellent (intraclass correlation coefficients ≥ .96). The SRD of the 4 scales was 10% of their corresponding highest score, indicating acceptable level of measurement error. The upper extremity and the lower extremity subscales of the 4 showed similar results. Conclusions. The 4 motor scales showed acceptable levels of reliability, validity, and responsiveness in stroke patients. The S-STREAM is recommended because it is short, responsive to change, and able to discriminate patients with severe or mild stroke.


Sign in / Sign up

Export Citation Format

Share Document