scholarly journals Rehabilitation of visual functions in adult amblyopic patients with a virtual reality videogame: a case series

2021 ◽  
Author(s):  
Carmen Jiménez-Rodríguez ◽  
Lourdes Yélamos-Capel ◽  
Patricia Salvestrini ◽  
Cristian Pérez-Fernández ◽  
Fernando Sánchez-Santed ◽  
...  

AbstractAmblyopia or lazy eye is a dysfunction of the visual system that appears during childhood and traditionally has been considered untreatable in adults. Its main consequences are the loss of visual acuity and contrast sensitivity of the amblyopic eye and binocular vision impairments. During the last years videogames have been used as a therapeutic tool for amblyopia with the inconclusive results. The present work has assessed the effectiveness of a virtual reality videogame (AmbliOK®) in the neurorehabilitation of four adult clinical cases with anisometropic amblyopia. Visual acuity, contrast sensitivity, stereopsis and interocular suppression were assessed before, during, immediately after, one month and one year (in one patient) after the training. The intervention was conducted along four weeks (10 h) and yielded the variable results. In general, all patients showed an improvement in visual functions although not all ameliorated in the same way. Visual acuity measures improved in all patients, falling outside the amblyopia criterion at the end of the treatment. However, the improvement was not maintained one month later in two patients. Contrast sensitivity progressively improved for the amblyopic and the fellow eyes with all patients showing better results one month after the treatment. The patient assessed one year after still showed better results than in the baseline. Patients showing bad stereopsis in the baseline reached a performance considered normal one month and even one year after the treatment. The effectiveness of the treatment seems to be related to the characteristics of patients.

2021 ◽  
pp. 112067212110637
Author(s):  
Victor A Augustin ◽  
Hyeck-Soo Son ◽  
Isabella Baur ◽  
Ling Zhao ◽  
Gerd U Auffarth ◽  
...  

Purpose To analyze the tomographically non-affected second eyes of keratoconus patients using the Corvis ST to detect any biomechanical abnormalities or subclinical keratoconus. Methods In this retrospective, single-center, consecutive case series 244 eyes of 122 keratoconus patients were analyzed between November 2020 and February 2021. Fourteen fellow eyes fulfilled the inclusion criteria and showed no clinical or tomographic signs of keratoconus. Main outcome measures included best-corrected visual acuity, tomographic and biomechanical analyses using Scheimpflug imaging: Pentacam and Corvis ST (Oculus, Wetzlar, Germany). Tomographic analyses included anterior and posterior simulated keratometry, K-Max, central corneal thickness, thinnest corneal thickness, Belin/Ambrosio Ectasia Display, and the ABCD grading system. For biomechanical analyses, the corneal biomechanical index (CBI) and tomographic biomechanical index were used. Results The mean best-corrected visual acuity was 0.01 ± 0.10 logMAR. Mean K-Max was 43.79 ± 1.12 D, mean central corneal thickness 529 ± 25 µm, mean thinnest corneal thickness 524 ± 23 µm, and mean Belin/Ambrosio Ectasia Display 1.0 ± 0.32. The mean CBI was 0.30 ± 0.21. Regular CBI values were found in six of 14 patients. The mean tomographic biomechanical index was 0.47 ± 0.22 with regular values observed in only two of 14 patients. No signs of tomographic or biomechanical abnormalities were shown in only one of 14 keratoconus fellow eyes, with regular ABCD, Belin/Ambrosio Ectasia Display, CBI and tomographic biomechanical index values. Conclusions Tomographically normal fellow eyes of keratoconus patients are rare. In these cases, a biomechanical analysis of the cornea may help detect a subclinical keratoconus. The tomographic biomechanical index was the most sensitive index to verify a mild ectasia.


2015 ◽  
Vol 9 (1) ◽  
pp. 131-135 ◽  
Author(s):  
Irena Tsui ◽  
Robert M Beardsley ◽  
Tara A McCannel ◽  
Scott C Oliver ◽  
Melissa W Chun ◽  
...  

Purpose : To report visual acuity, contrast sensitivity and color vision prior to, 1 year after, 2 years after and 3 years after iodine-125 brachytherapy for choroidal and ciliary body melanoma (CCM). Design : Prospective interventional case series. Participants : Thirty-seven patients (37 eyes) with CCM. Methods : Patients had best-corrected Early Treatment Diabetic Retinopathy Study (ETDRS) visual acuity, Pelli-Robson contrast sensitivity and Hardy-Rand-Rittler color vision measurement; comprehensive ophthalmology examination; optical coherence tomography; and ultrasonography at baseline prior to, 1 year after, 2 years after and 3 years after I-125 brachytherapy. Main Outcome Measures : Visual acuity, contrast sensitivity and color vision prior to, 1 year after, 2 years after and 3 years after brachytherapy. Results : Nineteen (19) men and 18 women with mean age of 58 years (SD 13, range 30-78) prior to, 1 year after, 2 years after and 3 years after brachytherapy had mean best-corrected visual acuity of 77 letters (20/32), 65 letters (20/50), 56 letters (20/80) and 47 letters (20/125); contrast sensitivity of 30, 26, 22 and 19 letters; color vision of 26, 20, 17 and 14 test figures, respectively. Decrease in visual acuity, contrast sensitivity and color vision was statistically significant from baseline at 1 year, 2 years, and 3 years after brachytherapy. Decreased acuity at 3 years was associated with mid-choroid and macula melanoma location, ≥ 4.1 mm melanoma height, radiation maculopathy and radiation optic neuropathy. Conclusion : 1, 2 and 3 years after brachytherapy, eyes with CCM had significantly decreased visual acuity, contrast sensitivity and color vision.


2018 ◽  
Vol 28 (4) ◽  
pp. 419-424 ◽  
Author(s):  
Jorge L Alió ◽  
Ana B Plaza-Puche ◽  
Jorge L Alió del Barrio ◽  
Pedro Amat-Peral ◽  
Vicente Ortuño ◽  
...  

Purpose: To evaluate clinical and visual outcomes, quality of near vision, and intraocular optical quality of patients bilaterally implanted with a trifocal PanOptix intraocular lens. Methods: In this prospective consecutive case-series study, 52 eyes of 26 bilateral patients (mean age, 60.2 ± 7.4 years) were implanted with the AcrySof IQ Panoptix intraocular lens. Visual acuity, defocus curve, contrast sensitivity (Pelli-Robson test), near activity visual questionnaire, and internal aberrations with Osiris were evaluated. A prototype light-distortion analyzer was used to quantify the postoperative light-distortion indices. The follow-up was 6 months after surgery. Results: Uncorrected, corrected distance, and uncorrected near visual acuities improved with the surgery (p ≤ 0.02). Distance corrected near visual acuity was 0.13 ± 0.10, 0.13 ± 0.13, and 0.13 ± 0.08 at 1, 3, and 6 months after surgery, respectively (p = 0.82). Distance corrected intermediate visual acuities were 0.09 ± 0.13, 0.13 ± 0.15, and 0.12 ± 0.12 at 1, 3, and 6 months, postoperatively. Binocular contrast sensitivity was 1.86 ± 0.15 Log Units. Defocus curve provided a visual acuity equal or better to 0.30 LogMAR between defocus levels of +0.50 to −3.00 D. The near activity visual questionnaire scores improved significantly with the surgery (p < 0.01). Conclusion: The AcrySof IQ Panoptix intraocular lens is able to restore visual function with an acceptable intermediate and near vision after cataract surgery with good contrast sensitivity and an improvement in the near activity visual questionnaire.


Author(s):  
David Sproule ◽  
Rosemarie Figueroa Jacinto ◽  
Steve Rundell ◽  
Jacob Williams ◽  
Sam Perlmutter ◽  
...  

Virtual reality (VR) and personal head-mounted displays (HMDs) can be a viable tool for the presentation of scientifically accurate and valid demonstrative data in the courtroom. However, the capabilities and limitations of the technology need to be fully characterized. The current pilot study evaluated visual acuity and contrast sensitivity using two commercially available HMDs (Oculus Rift and HTC Vive Pro). Preliminary findings indicated that visual acuity and contrast sensitivity experienced in VR may be less than what is experienced in real-world scenarios. The current pilot study provides a quantitative approach for characterizing the limitations of VR with respect to visual acuity and contrast sensitivity, and provides recommendations for the appropriate use of this technology when performing forensic investigations and developing visualization tools.


2016 ◽  
Vol 23 (11) ◽  
pp. 1422-1428
Author(s):  
Faheem Ahmad ◽  
Syeda Iqra Iqbal

Introduction: Any opacity in crystalline clear lens that may or maynot impaired vision is called cataract. According to maturity of cataract it may beimmature, mature or hypermature. When a patient develop cataract than there isno significant medical treatment for cataract. Surgery is the treatment of choice forcataract. Phacoemulsification (phaco), a modification of ECCE, has found worldwidepopularity in last two decades. Objectives: To find out visual acuity and complicationsof phacoemulsification in patients operated by senior surgeon during learning curve.Study Design: Descriptive case series. Settings: Department of OphthalmologyIndependent University Hospital, Faisalabad. Period: One year from 01-04-2014to 31-03-2015. Data Collection Methods: Patients coming through the OPD ofthe eye department who fulfilled the inclusion criteria were enrolled and informedconsent was taken from all patients. Results: In this study 100 eyes had undergonePhacoemulsification with IOL under Local anesthesia during study period. The meanage of patients was 57.50 years (range 30-85 years). Regarding the visual acuity inoperated eyes, 80 eyes ( 80 %) had a BCVA of 6/6-6/12, 12 eyes (12 %) had a BCVA of6/18 to 6/36 and 6 eyes (6 %) had a BCVA of 6/60 to CF. While only 2 percent Patienthad visual acuity less than Counting finger(CF). Discussion: During phaco training,the author was taught in stepwise about various stages of phaco and then authorpractice single part every stage of phaco multiple times to be master in every step ofphaco under supervision of an experienced ophthalmologist. Due to learning of phacostep-by-step leads to good surgical outcomes and least complication rates. Afterlearning the phaco basic training, the author started to perform phacoemulsification inIndependent University Hospital Faisal Abad under the supervision of an experiencedophthalmologist followed by independently performing phacoemulsification.Conclusion: Surgeon experienced in ophthalmic surgery along with adequatephacoemulsification training leads to a good visual outcome with minimum peroperativeand post-operative complications.


2021 ◽  
Vol 2021 ◽  
pp. 1-9
Author(s):  
Sylwia Wagner ◽  
Grzegorz Wagner ◽  
Ewa Mrukwa-Kominek

Purpose. Long-term evaluation of the visual refractive outcomes and the quality of life after implantation of the WIOL-CF (Medicem, Czech Republic) in both eyes. Design. retrospective, nonrandomized noncomparative case series. Methods. 50 eyes of 25 patients, including 11 women (44%) and 14 men (56%). The age range of the patients was 38 to 77 years (mean age 55.48 ± 10.97 years). All patients underwent bilateral implantation of the WIOL-CF. Exclusion criteria were previous ocular surgeries except for cataract surgery and refractive lens exchange, irregular corneal astigmatism of >1.0 diopter, and ocular pathologies or corneal abnormalities. Postoperative examinations were performed at 14 days and 3, 6, 12 months of surgery; the last follow-up was between 24 and 36 months after the procedure. All exams included manifest refraction, monocular uncorrected visual acuity (UCVA) and distance-corrected visual acuity (DCVA) in 5 m (Snellen), monocular uncorrected visual acuity in 70 cm and 40 cm (Jeager) and binocular UCVA, DCVA in 5 m, 70 cm, and 40 cm, binocular contrast sensitivity (CS) under photopic conditions, binocular defocus curves, high-order aberrations, quality-of-vision VF-14 questionnaire, and spectacle independence. Results. Significant improvement in monocular visual acuity at all distances was demonstrated; the mean postoperative spherical equivalent was 0.32 ± 0.45D. The postoperative means of binocular distance UCVA and BCVA were also improved ( p  < .001) and so were the mean uncorrected intermediate VA (2.053 ± 1.268) and near uncorrected VA (2.737 ± 1.447). There was a significant improvement in contrast sensitivity at all spatial frequencies and higher-order aberration, compared to preoperative results. Conclusions. The evaluation of a WIOL-CF showed good distance, intermediate, and near visual acuity. Contrast sensitivity increased after surgery in all spatial frequencies. Patient satisfaction was high despite some optical phenomena. The rate of postoperative spectacle independence also turned out high. Financial Disclosure. No author has a financial or proprietary interest in any material or method mentioned.


2019 ◽  
Vol 6 (4) ◽  
pp. 1295
Author(s):  
Abdulaziz Alaqsam ◽  
Mohanna AL-Jindan ◽  
Ammar Almahmod ◽  
Ibrahim Gosadi

Background: Intrastromal corneal ring segment (ICRS) implantation is one of the treatment options of keratoconus. This study is aiming to evaluate safety and effectivness of ICRS implantation at Al-Dharan Eye Specialist Hospital.Methods: This study is a descriptive retrospective case series study. The target population of this study is patients diagnosed with corneal ectasia who underwent ICRS implantation in Al-Dharan Eye Specialist Hospital, Al-Dharan, Saudi Arabia. Preoperative and postoperative data about uncorrected visual acuity (UCVA), best spectacle–corrected visual acuity (BSCVA), manifest refraction, keratometry, applanation tonometry, corneal topography, and slit-lamp biomicroscopy and indirect ophthalmoscopy were retrieved from medical records of department of Medical Archive. Paired students t-test was used to compare preoperative and postoperative means of study variables.Results: The total number of recruited patients in this study was 57 patients where 62% of them were males. Sixty-six treated eyes were included in this study where no intra-operative complications were recorded. Upon comparing the mean preoperative data to the mean postoperative data at three months, six months and one year intervals, an overall improvement in the measured outcomes was witnessed. UCVA, BSCVA, and keratometric readings exhibited a statistically significant improvement when comparing preoperative with one-year postoperative findings (p<0.001).Conclusions: The findings of this study indicate that ICRS implantation is a safe and effective treatment for keratoconus.


Author(s):  
Kirti Singh ◽  
Mainak Bhattacharyya ◽  
Abhishek Goel ◽  
Ritu Arora ◽  
Nikhil Gotmare ◽  
...  

Purpose: Literature is relatively silent on safety profile and predictability of orthokeratology lenses in terms of myopia correction and prevention of further progression, especially in semi-tropical countries; this study was designed to fill this gap. Methods: This prospective, intervention case series enrolled 30 eyes of 30 patients with myopia up to –5.5 diopters (D). Patients were randomized into two groups of 15 each; the study group was prescribed overnight orthokeratology (OK) lenses, while the control group used daily wear conventional soft contact lenses. Follow-up examinations were performed after 1 h and 6 h, and then at 1, 7, 15, 30 days, and 4 months post lens wear. Uncorrected visual acuity (UCVA), contrast sensitivity, keratometry, central corneal thickness (CCT), and tear film break up time (TBUT) were evaluated at each follow-up examination. Results: All patients attained a visual acuity of 0.00 Logarithm of the Minimum Angle of Resolution (logMAR) after one week of lens use, which was maintained throughout the study period. While patients allotted to the study group had a gain of 8.1 Snellen lines (UCVA), those in the control group gained 8.9 lines (BCVA) at the end of follow-up period. In the OK group, cornea showed a flattening of 0.8 D (mean keratometry) after single overnight usage of OK lens and overall flattening of 1.2 D compared to baseline, at the end of four months. The change in contrast sensitivity, corneal endothelial specular count, axial length and tear film status was not significant in either group. Conclusion: Orthokeratology is an effective and safe modality to correct moderate myopia in motivated young adults. No side effects were encountered after a short-term follow-up in participants who resided in semi-tropical environments.


2016 ◽  
Vol 27 (4) ◽  
pp. 438-442 ◽  
Author(s):  
Torsten Schlote ◽  
Alexander Heuberger

Purpose To evaluate the efficacy and safety of the multifocal excimer laser corneal ablation profile (the Supracor procedure) in hyperopic presbyopia 1 year after laser treatment. Methods This prospective, consecutive, one-center, cross-sectional study included 20 patients with hyperopic presbyopia 1 year after treatment with the Supracor procedure. The main outcome measures were monocular uncorrected distance visual acuity (UDVA) and uncorrected near visual acuity (UNVA), photopic contrast sensitivity (Pelli-Robson charts), patient satisfaction, and functioning at 12 months. Results Thirty-nine eyes of 20 patients (mean age 59 ± 7.2 years) were treated. Mean UDVA improved from 0.56 ± 0.31 (mean 0.34 logMAR) preoperatively to 0.9 ± 0.15 (mean 0.06 logMAR) 12 months after surgery. Mean UNVA increased from 0.15 ± 0.07 (mean 0.84 logMAR) before surgery to 0.62 ± 0.24 (mean 0.23 logMAR) 12 months after treatment. Four eyes lost 2 lines of corrected distance visual acuity (10.3%). Monocular photopic contrast sensitivity was within age-correlated normal range (Pelli-Robson chart, mean contrast sensitivity 1.83 ± 0.18). A total of 75% of the patients would undergo Supracor again (1 not, 4 perhaps). The most frequently reported side effects were increased glare, reduced distance vision, and fluctuations in vision. Most patients used artificial tears. Conclusions One year after Supracor, UDVA and UNVA improved markedly, photopic contrast sensitivity was in normal age-correlated range, and the majority of patients (75%) was satisfied with the results. Side effects like loss of distance vision, fluctuations of vision, and increased glare have a greater influence on patient satisfaction than the improvement of spectacle-free near vision.


2020 ◽  
Vol 2020 ◽  
pp. 1-6 ◽  
Author(s):  
Ahmed E. M. Shehata ◽  
James W. Foster ◽  
Albert S. Jun ◽  
Uri S. Soiberman

Purpose. This study aims to correlate the clinical signs of keratoconus (KC) which include superficial apical scarring, Fleischer rings, and Vogt striae with best spectacle-corrected visual acuity (BSCVA) and corneal tomography findings. Patients and methods. A retrospective observational study. 72 consecutive KC patients seen by the senior author over the course of one year were included in this case series. Eyes with pellucid marginal degeneration, postrefractive ectasia, history of a corneal graft, prior corneal collagen cross-linking, intracorneal ring segments or hydrops were excluded from analysis. Subsequently, the final analysis included only treatment-naïve KC eyes with varying degrees of disease severity. Results. BSCVA with manifest refraction was 0.5 logMAR higher in eyes with apical scarring (p<0.001). Eyes with apical scarring had worse vision than eyes with Fleischer rings alone (0.43 logMAR higher in the former, p<0.009). Eyes with apical scarring had higher keratometry readings (K2 = 64.56 ± 12.89 D versus 49.07 ± 6.61 D, p<0.001); this was also true for eyes with Fleischer rings compared with ring-free eyes (K2 = 56.23 ± 11.52 D versus 48.91 ± 7.79 D, p<0.001) and eyes with Vogt striae (K2 = 56.19 ± 10.27 D versus 50.68 ± 9.21 D, p=0.01). Atopic disease was a risk factor for scarring: odds ratio (OR) = 2.87 (p=0.03). The OR of observing Fleischer rings in KC eyes was 12% per year (p=0.001). Additionally, each mm of corneal apex displacement from the pupillary center led to a 0.76 logMAR increase in visual acuity (p=0.001). Conclusion. The presence of apical scarring and Fleischer rings on biomicroscopy can aid the clinician in making the distinction between severe or long-standing disease (respectively). Apical scarring is a sign of advanced disease and is associated with worse BSCVA and tomography findings. Fleischer rings are markers of intermediate disease and their presence correlates with disease duration.