scholarly journals Mobility-on-demand pricing versus private vehicle TCO: how cost structures hinder the dethroning of the car

2021 ◽  
Author(s):  
Tobias Kuhnimhof ◽  
Christine Eisenmann

AbstractThis study uses a unique dataset on the cost of motoring in Germany to analyse cost competitiveness of emerging mobility-on-demand (MOD) services. Previous studies have focused on comparing current and projected MOD prices with the average cost of private motoring. This study quantifies which proportion of private car travel would actually turn out to be costlier than MOD given that MOD costs drop below certain levels relative to the cost of private motoring. In this context, not the average but the distribution of the costs of motoring are the key issue. These costs are strongly skewed across the cars in private households when including new and old vehicles: a large proportion of private car kilometres are driven at relatively low cost. The study uses simplified scenario settings with MOD price levels ranging from 0.1 €/km to 1.5 €/km to make predictions of hypothetical modal shifts under the assumption that car user switch to the most economic mode of travel. These modal shifts serve as an indicator of MOD cost competitiveness. The results indicate that MOD prices would have to drop to 0.5 €/km or lower to have a notable impact on use of the private car if cost was the key mode choice criterion. Only if MOD prices drop down to a level of about 0.3 €/km—quite possibly a lower boundary for automated MOD—MOD-enabled mobility packages would be the less costly alternative to the private car for a substantial proportion of mileage. However, even at that MOD price level, the private car would still be the most economic option for the majority of today’s car user kilometres. Our findings illustrate that the skewed distribution of the cost of owning and running private cars—where many of those who drive much drive inexpensively—substantially dampens the disruptive potential of MOD. While we use data from Germany to illustrate this, many of our findings are more widely applicable.

2017 ◽  
Vol 200 ◽  
pp. 621-637 ◽  
Author(s):  
Katie R. Smith ◽  
Peter M. Edwards ◽  
Mathew J. Evans ◽  
James D. Lee ◽  
Marvin D. Shaw ◽  
...  

Low cost air pollution sensors have substantial potential for atmospheric research and for the applied control of pollution in the urban environment, including more localized warnings to the public. The current generation of single-chemical gas sensors experience degrees of interference from other co-pollutants and have sensitivity to environmental factors such as temperature, wind speed and supply voltage. There are uncertainties introduced also because of sensor-to-sensor response variability, although this is less well reported. The sensitivity of Metal Oxide Sensors (MOS) to volatile organic compounds (VOCs) changed with relative humidity (RH) by up to a factor of five over the range of 19–90% RH and with an uncertainty in the correction of a factor of two at any given RH. The short-term (second to minute) stabilities of MOS and electrochemical CO sensor responses were reasonable. During more extended use, inter-sensor quantitative comparability was degraded due to unpredictable variability in individual sensor responses (to either measurand or interference or both) drifting over timescales of several hours to days. For timescales longer than a week identical sensors showed slow, often downwards, drifts in their responses which diverged across six CO sensors by up to 30% after two weeks. The measurement derived from the median sensor within clusters of 6, 8 and up to 21 sensors was evaluated against individual sensor performance and external reference values. The clustered approach maintained the cost competitiveness of a sensor device, but the median concentration from the ensemble of sensor signals largely eliminated the randomised hour-to-day response drift seen in individual sensors and excluded the effects of small numbers of poorly performing sensors that drifted significantly over longer time periods. The results demonstrate that for individual sensors to be optimally comparable to one another, and to reference instruments, they would likely require frequent calibration. The use of a cluster median value eliminates unpredictable medium term response changes, and other longer term outlier behaviours, extending the likely period needed between calibration and making a linear interpolation between calibrations more appropriate. Through the use of sensor clusters rather than individual sensors, existing low cost technologies could deliver significantly improved quality of observations.


Author(s):  
R. E. Barber

Solar heat can be converted into shaft power by use of the Organic Rankine Cycle Engine (ORCE). The efficiency of the ORCE to convert the solar heat to shaft power varies from 7 or 8 percent for an ORCE heated by low temperature flat plate collectors at 200 F, to near 15 percent when heated by intermediate temperature collectors (300 F), and up to 25 percent with high temperature concentrating collectors (600 F). Barber-Nichols designed, built, and tested its first solar heated ORCE in 1973, which produced three tons of air conditioning. Since that time, the three-ton unit has reached its fourth iteration on the development path to production; a 77-ton water chiller was installed at LASL; two ORCE drives for 100-ton water chillers were delivered to Honeywell; seven 25-ton water Chillers were delivered to DOE demonstration sites; and a 25-hp ORCE for irrigation pumping was installed in Willard, N.M. Photographs, design details, and the measured performance of these units are presented herein as examples. The cost of solar power systems using an ORCE is also presented which shows that for the current $150 to $200/m2 cost of cencentrating collectors, the system cost would be in excess of $2500/kw peak. The ORCE is approximately 25 percent of this cost or $600/kw. Consequently, while reductions in the cost and improvements in the performance of the ORCE can and should be made in the development process, the cost competitiveness of a solar power system is largely dependent on developing low cost concentrating collectors which can be sold for 1/2 to 1/3 of today’s price.


2020 ◽  
Vol 4 (1) ◽  
pp. 22 ◽  
Author(s):  
John Cotter ◽  
Rasim Guldiken

Due to increasing costs and growing environmental concerns pertaining to the construction of structures, an alternative form of reinforcement has been proposed through our studies; through a new beam design methodology, referred to as triple composite beams, glass can be used as a cost-competitive and more environmentally friendly macro-scale compressive reinforcement. The cost competitiveness of glasses derives from their large compressive strength (in general 1000 MPa; >1100 MPa for fused quartz). To support the triple composite design architecture, equations have been developed using Euler–Bernoulli beam theory and the method of transformed sections and compared against finite element modeling determined stresses. Our results show that the average stress was more accurate but less precise than fully considering binder, assuming the binder did not contribute to the cross-section of the beam. The paper concludes by presenting a flexural reinforcement utilization ratio (R), which predicts the ability of a reinforcement-binder combination to utilize the reinforcement to maximum stress effectively while ignoring bonding strength. This R ratio suggests that while concrete is a low cost, it cannot be used in a glass-reinforced beam as the concrete is too stiff compared to the glass.


2019 ◽  
Vol 12 (3) ◽  
pp. 1856-1859
Author(s):  
Harendra Nishantha Kariyawasam

This study focuses on analyzing the variables affecting the average operating cost per aircraft movement. Since airlines around the world are operated on thin profit margins and with increasing competition from Low Cost Carriers it will be important for an airline to get a complete understanding about their operating cost structure. The aim of this study is to suggest an airline of actions to reduce their operating cost and will differentiate the cost structures of Low Cost Carriers and Full Service Carriers. This study was conducted for 20 airlines which were operating in Asia Pacific region. Published financial and statistical data were used for analysis and a parametric approach was used. The results of this study do not suggest economies of scale for the airline, which is to have higher number of aircraft to reduce cost.


Author(s):  
Karan S Belsare ◽  
Gajanan D Patil

A low cost and reliable protection scheme has been designed for a three phase induction motor against unbalance voltages, under voltage, over voltage, short circuit and overheating protection. Taking the cost factor into consideration the design has been proposed using microcontroller Atmega32, MOSFETs, relays, small CTs and PTs. However the sensitivity of the protection scheme has been not compromised. The design has been tested online in the laboratory for small motors and the same can be implemented for larger motors by replacing the i-v converters and relays of suitable ratings.


2019 ◽  
Vol 2019 (4) ◽  
pp. 7-22
Author(s):  
Georges Bridel ◽  
Zdobyslaw Goraj ◽  
Lukasz Kiszkowiak ◽  
Jean-Georges Brévot ◽  
Jean-Pierre Devaux ◽  
...  

Abstract Advanced jet training still relies on old concepts and solutions that are no longer efficient when considering the current and forthcoming changes in air combat. The cost of those old solutions to develop and maintain combat pilot skills are important, adding even more constraints to the training limitations. The requirement of having a trainer aircraft able to perform also light combat aircraft operational mission is adding unnecessary complexity and cost without any real operational advantages to air combat mission training. Thanks to emerging technologies, the JANUS project will study the feasibility of a brand-new concept of agile manoeuvrable training aircraft and an integrated training system, able to provide a live, virtual and constructive environment. The JANUS concept is based on a lightweight, low-cost, high energy aircraft associated to a ground based Integrated Training System providing simulated and emulated signals, simulated and real opponents, combined with real-time feedback on pilot’s physiological characteristics: traditionally embedded sensors are replaced with emulated signals, simulated opponents are proposed to the pilot, enabling out of sight engagement. JANUS is also providing new cost effective and more realistic solutions for “Red air aircraft” missions, organised in so-called “Aggressor Squadrons”.


2021 ◽  
Vol 27 (1) ◽  
Author(s):  
J. M. Lazarus ◽  
M. Ncube

Abstract Background Technology currently used for surgical endoscopy was developed and is manufactured in high-income economies. The cost of this equipment makes technology transfer to resource constrained environments difficult. We aimed to design an affordable wireless endoscope to aid visualisation during rigid endoscopy and minimally invasive surgery (MIS). The initial prototype aimed to replicate a 4-mm lens used in rigid cystoscopy. Methods Focus was placed on using open-source resources to develop the wireless endoscope to significantly lower the cost and make the device accessible for resource-constrained settings. An off the shelf miniature single-board computer module was used because of its low cost (US$10) and its ability to handle high-definition (720p) video. Open-source Linux software made monitor mode (“hotspot”) wireless video transmission possible. A 1280 × 720 pixel high-definition tube camera was used to generate the video signal. Video is transmitted to a standard laptop computer for display. Bench testing included latency of wireless digital video transmission. Comparison to industry standard wired cameras was made including weight and cost. The battery life was also assessed. Results In comparison with industry standard cystoscope lens, wired camera, video processing unit and light source, the prototype costs substantially less. (US$ 230 vs 28 000). The prototype is light weight (184 g), has no cables tethering and has acceptable battery life (of over 2 h, using a 1200 mAh battery). The camera transmits video wirelessly in near real time with only imperceptible latency of < 200 ms. Image quality is high definition at 30 frames per second. Colour rendering is good, and white balancing is possible. Limitations include the lack of a zoom. Conclusion The novel wireless endoscope camera described here offers equivalent high-definition video at a markedly reduced cost to contemporary industry wired units and could contribute to making minimally invasive surgery possible in resource-constrained environments.


Sensors ◽  
2021 ◽  
Vol 21 (10) ◽  
pp. 3515
Author(s):  
Sung-Ho Sim ◽  
Yoon-Su Jeong

As the development of IoT technologies has progressed rapidly recently, most IoT data are focused on monitoring and control to process IoT data, but the cost of collecting and linking various IoT data increases, requiring the ability to proactively integrate and analyze collected IoT data so that cloud servers (data centers) can process smartly. In this paper, we propose a blockchain-based IoT big data integrity verification technique to ensure the safety of the Third Party Auditor (TPA), which has a role in auditing the integrity of AIoT data. The proposed technique aims to minimize IoT information loss by multiple blockchain groupings of information and signature keys from IoT devices. The proposed technique allows IoT information to be effectively guaranteed the integrity of AIoT data by linking hash values designated as arbitrary, constant-size blocks with previous blocks in hierarchical chains. The proposed technique performs synchronization using location information between the central server and IoT devices to manage the cost of the integrity of IoT information at low cost. In order to easily control a large number of locations of IoT devices, we perform cross-distributed and blockchain linkage processing under constant rules to improve the load and throughput generated by IoT devices.


Micromachines ◽  
2021 ◽  
Vol 12 (8) ◽  
pp. 882
Author(s):  
M. Munzer Alseed ◽  
Hamzah Syed ◽  
Mehmet Cengiz Onbasli ◽  
Ali K. Yetisen ◽  
Savas Tasoglu

Civil wars produce immense humanitarian crises, causing millions of individuals to seek refuge in other countries. The rate of disease prevalence has inclined among the refugees, increasing the cost of healthcare. Complex medical conditions and high numbers of patients at healthcare centers overwhelm the healthcare system and delay diagnosis and treatment. Point-of-care (PoC) testing can provide efficient solutions to high equipment cost, late diagnosis, and low accessibility of healthcare services. However, the development of PoC devices in developing countries is challenged by several barriers. Such PoC devices may not be adopted due to prejudices about new technologies and the need for special training to use some of these devices. Here, we investigated the concerns of end users regarding PoC devices by surveying healthcare workers and doctors. The tendency to adopt PoC device changes is based on demographic factors such as work sector, education, and technology experience. The most apparent concern about PoC devices was issues regarding low accuracy, according to the surveyed clinicians.


2021 ◽  
Vol 2 (2) ◽  
pp. 325-334
Author(s):  
Neda Javadi ◽  
Hamed Khodadadi Tirkolaei ◽  
Nasser Hamdan ◽  
Edward Kavazanjian

The stability (longevity of activity) of three crude urease extracts was evaluated in a laboratory study as part of an effort to reduce the cost of urease for applications that do not require high purity enzyme. A low-cost, stable source of urease will greatly facilitate engineering applications of urease such as biocementation of soil. Inexpensive crude extracts of urease have been shown to be effective at hydrolyzing urea for carbonate precipitation. However, some studies have suggested that the activity of a crude extract may decrease with time, limiting the potential for its mass production for commercial applications. The stability of crude urease extracts shown to be effective for biocementation was studied. The crude extracts were obtained from jack beans via a simple extraction process, stored at room temperature and at 4 ℃, and periodically tested to evaluate their stability. To facilitate storage and transportation of the extracted enzyme, the longevity of the enzyme following freeze drying (lyophilization) to reduce the crude extract to a powder and subsequent re-hydration into an aqueous solution was evaluated. In an attempt to improve the shelf life of the lyophilized extract, dextran and sucrose were added during lyophilization. The stability of purified commercial urease following rehydration was also investigated. Results of the laboratory tests showed that the lyophilized crude extract maintained its activity during storage more effectively than either the crude extract solution or the rehydrated commercial urease. While incorporating 2% dextran (w/v) prior to lyophilization of the crude extract increased the overall enzymatic activity, it did not enhance the stability of the urease during storage.


Sign in / Sign up

Export Citation Format

Share Document