scholarly journals Development and Validation of a UHPLC-MS/MS Method for the Analysis of Fusarium Mycotoxins in Onion

Author(s):  
Sari Rämö ◽  
Minna Haapalainen ◽  
Satu Latvala

AbstractFusarium basal rot (FBR) of onion is a serious disease problem worldwide. The Fusarium species causing FBR can also produce mycotoxins that are potentially harmful to humans and animals. In this study, a multiple reaction monitoring technique with ultra-high-performance liquid chromatography–tandem mass spectrometry (MRM UHPLC-MS/MS) was developed and validated for onion matrix to study Fusarium mycotoxins in the harvested onions. This study was focused on fumonisins B1, B2, and B3 (FB1, FB2, and FB3), beauvericin (BEA), and moniliformin (MON), which are the main mycotoxins produced by Fusarium oxysporum and Fusarium proliferatum. In the in-house validated protocol, the onion samples were extracted with methanol:water (3:1) using magnetic stirring for 15 min. FBs and BEA were determined directly from the filtered extracts, whereas MON required sample concentration prior to analysis. No cleanup of extracts was needed prior to analysis. The target mycotoxins were separated on an Acquity UPLC system BEH C18 column with gradient elution. Mycotoxins were identified and quantified using 13C-FB1 as internal standard. Minor matrix effect was compensated using multi-point matrix-matched calibration curves with uninfected onion sample. For the mycotoxins studied, a good linearity was obtained (R2 ≥ 0.99) and the recoveries were in the range of 67–122%, with the highest standard deviation for MON, 22%. The limits of quantification were from 2.5 to 10 ng g−1 in onion matrix. The method was successfully employed for the analysis of mycotoxins in harvested onions showing FBR symptoms and found to be infected with F. oxysporum and F. proliferatum.

Author(s):  
Maria Rincon Nigro ◽  
Jing Ma ◽  
Ololade Tosin Awosemo ◽  
Huan Xie ◽  
Omonike Arike Olaleye ◽  
...  

OJT007 is a methionine aminopeptidase 1 (MetAP1) inhibitor with potent anti-proliferative effects against Leishmania Major. In order to study its pharmacokinetics as a part of the drug development process, a sensitive, specific, and reproducible ultra-high performance liquid chromatography-tandem mass spectrometry (UPLC-MS/MS) method was developed and validated. Voriconazole was used as the internal standard to generate standard curves ranging from 5 to 1000 ng/mL. The separation was achieved using a UPLC system equipped with an Acquity UPLC BEH C18 column (2.1 × 50 mm, 1.7 μm) with 0.1% formic acid in acetonitrile and 0.1% formic acid in water as the mobile phase under gradient elution at a flow rate of 0.4 mL/min. The mass analysis was performed with a 4000 QTRAP® mass spectrometer using multiple-ion reaction monitoring (MRM) in the positive mode, with the transition of m/z 325 → m/z 205 for OJT007 and m/z 350 → m/z 101 for voriconazole. The intra- and inter-day precision and accuracy were within ±15%. The mean extraction recovery and the matrix effect were 95.1% and 7.96%, respectively, suggesting no significant matrix interfering with the quantification of the drug in rat plasma. This study was successfully used for the pharmacokinetic evaluation of OJT007 using the rat as an animal model.


2020 ◽  
Vol 2020 ◽  
pp. 1-7
Author(s):  
Shuang-long Li ◽  
Yong-liang Zhu ◽  
Yi Zhang ◽  
Shu-han Liu ◽  
Xiang-die Wang ◽  
...  

In our research, a straightforward UPLC-MS/MS method, with diazepam as the internal standard (IS), was proposed and acknowledged to determine the concentrations of enasidenib in rat plasma. When preparing the sample, we used acetonitrile for protein precipitation. The gradient elution method was used, and the mobile phase was acetonitrile and 0.1% formic acid. Diazepam was used as the IS. We used the Acquity UPLC BEH C18 column to separate enasidenib and IS. Under the positive ion electrospray ionization (ESI) source conditions, the mass transfer pairs of enasidenib were monitored by multiple reaction monitoring (MRM) to be m/z 474.2 ⟶ 456.1 and m/z 474.2 ⟶ 267.0, and the IS mass transfer pairs were m/z 285.0 ⟶ 154.0. Enasidenib had good linearity (r2 = 0.9985) in the concentration range of 1.0–1000 ng/mL. Besides, the values of intraday and interday precision were 2.25–8.40% and 3.94–5.46%, respectively, and the range of the accuracy values varied from −1.44 to 2.34%. Matrix effect, extraction recovery, and stability were compliant with FDA approval guidelines in terms of bioanalytical method validation. We had established a new method that had been applied to the pharmacokinetic study of enasidenib in rats.


Author(s):  
Xiaorong Wu ◽  
Yankai Wang ◽  
Binbin Liang ◽  
Honghai Wu ◽  
Liying Wu ◽  
...  

AbstractAn ultra-high performance liquid chromatography-tandem mass spectrometry (UHPLC–MS/MS) method was developed to determine the fenofibric acid (FA) in human plasma and applied to a pharmacokinetic study of fenofibrate tablet (Lipanthyl® supra, 160 mg) on Chinese subjects which had not been reported. Bezafibrate was used as an internal standard (IS), and the plasma samples were precipitated by methanol. Multiple reaction monitoring (MRM) mode was used to quantitatively analyzed FA m/z 317.2 → 230.7 and the IS m/z 360.0 → 274.0 in the electrospray ionization (ESI) negative interface. The calibration curves were linear over the range of 50–30,000  ng/mL (r2  ≥  0.996). The intra-day and inter-day precision (coefficient of variation, CV%) was less than 2.7 and 2.5%, respectively. The accuracy (relative error, RE%) ranged from −4.5 to 6.9%. The average recovery was higher than 86.2%, and the matrix effect was between 95.32 and 110.55%. The simple, rapid, and selectivity method was successfully applied to the pharmacokinetic study of fenofibrate tablets on Chinese subjects.


2019 ◽  
Vol 9 (1) ◽  
Author(s):  
Qiang Wang ◽  
Xu-Feng Wang ◽  
Yong-Yuan Jiang ◽  
Zhi-Guang Li ◽  
Nan Cai ◽  
...  

AbstractWe developed a significantly improved ultra-high performance liquid chromatography-tandem mass spectrometry method for determination of 5-nitro-2-furaldehyde (NF) as a surrogate using a novel internal standard for the detection of nitrofurazone. We used 2,4-dinitrophenylhydrazine derivatization and furfural as the internal standard. Derivatization was easily performed in HCl using ultrasonic manipulation for 5 min followed by liquid extraction using ethyl acetate. The samples were concentrated and purified using reverse phase and alumina cartridges in tandem. The derivatives were separated using a linear gradient elution on a C18 column with methanol and water as the mobile phase in negative ionization mode and multiple reaction monitoring. Under the optimized conditions, the calibration curves were linear from 0.2 to 20 μg/L with correlation coefficients >0.999. Mean recoveries were 80.8 to 104.4% with the intra- and inter-day relative standard deviations <15% at spiking levels of 0.1 to 10 μg/kg. The limits of detection and quantification were 0.05 and 0.1 μg/kg, respectively. This method is a robust tool for the identification and quantitative determination of NF in shrimp samples.


2020 ◽  
Vol 58 (10) ◽  
pp. 922-928
Author(s):  
Jing Zhang ◽  
Quan Wen ◽  
Meng-ying Zhou ◽  
Chen-cong Zhong ◽  
Yulin Feng ◽  
...  

Abstract Chimonanthi Radix (CR) is widely used in the treatment of influenza in China. Extensive studies revealed that the major bioactive constituents of CR were coumarins. However, pharmacokinetic study of coumarins in CR has not been fully studied. The purpose of this study was to establish a convenient and effective high-performance liquid chromatography–tandem mass spectrometry method that was used to simultaneously determine scopoletin, scopolin and isofraxidin in rat plasma after oral administration of CR extract using xanthotoxin as the internal standard. The chromatographic separation was carried out on a COSMOCORE C18 column (100 × 2 mm, 2.6 μm), using gradient elution with the mobile phase consisting of 0.1% formic acid (A) and acetonitrile (B). Three coumarins and IS were quantified by positive ion electrospray ionization in multiple reaction monitoring mode. The method was fully validated in terms of specificity, accuracy, precision (intra- and inter-day), matrix effect, recovery as well as the stability of the analytes under various conditions. The results could provide further research foundation for anti-influenza mechanism of three coumarins in CR.


Author(s):  
Yonghui Shen ◽  
Deru Meng ◽  
Feifei Chen ◽  
Hui Jiang ◽  
Liming Hu ◽  
...  

AbstractSarecycline is a narrow-spectrum antibiotic for the treatment of acne, which is a chronic inflammatory disease of the hair follicle sebaceous glands. In the study, UPLC-MS/MS was used to establish a rapid and accurate analytical method. The sarecycline was determined with poziotinib as internal standard (IS) in rat plasma. An ACQUITY UPLC HSS T3 column (2.1 × 100 mm, 1.8 μm) could performe chromatographic separation with the mobile phase (methanol: water of 0.1% formic acid) with gradient elution. The ions of target fragment were m/z 488.19→410.14 for sarecycline and m/z 492.06→354.55 for poziotinib, which could quantify the electrospray ionization of positive multiple reaction monitoring (MRM) mode. The linear calibration curve of the concentration range was 1–1,000 ng/mL for sarecycline with a lower limit of quantification (LLOQ) of 1 ng/mL. The mean recovery was between 82.46 and 95.85% for sarecycline and poziotinib in rat plasma. RSD for precision of inter-day and intra-day were between 3.24 and 13.36%, and the accuracy ranged from 105.26 to 109.75%. The developed and validated method was perfectly used in the pharmacokinetic study and bioavailability of sarecycline after intravenous and oral administration in rats.


2019 ◽  
Vol 104 (6) ◽  
pp. e43.2-e43
Author(s):  
S Magreault ◽  
O Chaussenery-Lorentz ◽  
T Storme ◽  
E Jacqz-Aigrain

BackgroundAntimicrobials are widely used in children but pediatric dose regimens are not always validated, and PK studies, required to validate dosage, are difficult to conduct in children. Low sampling volume limits the number of PK samples drawn per patient and analytical methods adapted to small volumes are not always available. Due to the wide inter-patient pharmacokinetic (PK) variability in children, particularly neonates, therapeutic drug monitoring is required to adapt dosage to individual patients. In such clinical and analytical context, our aim was to develop a unique, rapid and highly sensitive ultra-performance liquid chromatography-tandem mass spectrometry (UPLC-MS/MS) assay to quantify 7 antibiotics (amoxicillin, azithromycin, cefotaxime, ciprofloxacin, meropenem, metronidazole and piperacillin) in low sample volumes (50 µL) for both routine monitoring and pharmacokinetic studies.MethodsAfter protein precipitation by acetonitrile, the antibiotics and their associated deuterated internal standard were separated on a Waters Acquity UPLC HSS T3 (100 mm x 2.1 mm; 1.8 µm). The mobile phases consisted of a gradient of ammonium acetate (pH 2.4; 5mM) and acetonitrile acidified with 0.1% (v/v) formic acid (started ratio of 93:7, v/v), run at 0.5 mL/min flow rate (total run time: 2.75 min). Ions were detected in the turbo-ion-spray-positive and multiple-reaction-monitoring modes.ResultsThis method was linear from 0.1–50 µg/mL. Accuracy and precision were evaluated using Quality Control (2, 10, 35 µg/mL). Validation of the method proved that precision, selectivity and stability were all within the recommended limits.ConclusionThis method has the advantage of a unique, efficient and standardized analytical tool for rapid measurement of 7 antibiotics in low blood volume. It has been successfully applied for routine activity and pharmacokinetic studies in children and neonates.Disclosure(s)Nothing to disclose.


2012 ◽  
Vol 2012 ◽  
pp. 1-8 ◽  
Author(s):  
Ravi Kumar Konda ◽  
B. R. Challa ◽  
Babu Rao Chandu ◽  
Kothapalli B. Chandrasekhar

A simple, sensitive, and rapid HPLC-MS/MS method was developed and validated for quantitative estimation of memantine in human plasma. Chromatography was performed on Zorbax SB-C18(4.6×75 mm, 3.5 μm) column. Memantine (ME) and internal standard Memantine-d6(MED6) were extracted by using liquid-liquid extraction and analyzed by LC-ESI-MS/MS using multiple-reaction monitoring (MRM) mode. The assay exhibited a linear dynamic range of 50.00–50000.00 pg/ml for ME in human plasma. This method demonstrated an intra- and interday precision within the range of 2.1–3.7 and 1.4–7.8%, respectively. Further intra- and interday accuracy was within the range of 95.6–99.8 and 95.7–99.1% correspondingly. The mean recovery of ME and MED6 was86.07±6.87and80.31±5.70%, respectively. The described method was successfully employed in bioequivalence study of ME in Indian male healthy human volunteers under fasting conditions.


2021 ◽  
Vol 12 ◽  
Author(s):  
Yingying Wang ◽  
Er-min Gu ◽  
Xiaoxiang Du ◽  
Ren-ai Xu ◽  
Guanyang Lin

The contribution of the metabolites of linezolid to the associated myelosuppression is unknown in patients who are renal impairment. In this research, the purpose of our experiment was to explore and develop a quick and robust ultra performance liquid chromatography tandem mass spectrometry (UPLC-MS/MS) assay for the determination of linezolid and its metabolite PNU-142300 in human serum simultaneously. The analytes were prepared using a simple and convenient approach with acetonitrile for protein crash, and then separated from the matrix on a Waters Acquity Ultra performance liquid chromatography (UPLC) BEH C18 (2.1 mm × 50 mm, 1.7 μm) column in a program of gradient elution, where the mobile phase was consisted of water with 0.1% formic acid and acetonitrile, and was placed at 0.40 ml/min flow rate. Multiple reaction monitoring (MRM) was employed and conducted for UPLC-MS/MS detection with ion transitions at m/z 338.01 → 296.03 for linezolid, m/z 369.96 → 327.98 for PNU-142300 and m/z 370.98 → 342.99 for tedizolid (Internal standard, IS), respectively. This method had good linearity respectively in the calibration range of 0.01–20 μg/ml for linezolid, and 0.05–100 μg/ml for PNU-142300. In the intra- and inter-day, the precision of linezolid and PNU-142300 was below 14.2%, and the accuracy in this method was determined to be from −9.7 to 12.8%. In addition, recovery and matrix effect of the analytes were all found to be acceptable, and the analytes during the assay and storage in serum samples were observed to be stable. The novel optimized UPLC-MS/MS assay was also successfully employed to determine the concentration levels of linezolid and PNU-142300 in human serum. The results showed that linezolid-associated myelosuppression occurs more frequently in patients with renal insufficiency, and the metabolite-to-parent concentration ratio of PNU-142300 is predicted to reduce this toxicity of myelosuppression.


Author(s):  
Jianwei Han ◽  
Wenbo Zhu ◽  
Ling Yu ◽  
Yajun Chen ◽  
Gaosong Wu ◽  
...  

AbstractA rapid, sensitive and convenient method based on ultra-high performance liquid chromatography tandem mass spectrometry (UHPLC-MS/MS) was developed and validated for the simultaneous quantification of calycosin-7-O-β-d-glucoside (CCSG), ononin, calycosin, (6aR,11aR)-9,10-dimethoxypterocarpan-3-O-β-d-glucopyanoside (DPPG), and 7,2′-dihydroxy-3′,4′-dimethoxyisoflavan-7-O-β-d-glucopyanoside (DIFG) in rat plasma after oral administration of the methanol extraction from Radix Astragali. Theophylline played the role of internal standard (IS). Preparation of plasma samples by liquid-liquid extraction method with ethyl acetate after precipitation of protein with methanol. The analytes were detected with a triple quadrupole tandem mass spectrometery (MS) in multiple reaction monitoring (MRM) mode and a positive ion electrospray ionization (ESI). The method was validated with the concentration ranges of 1.96–62.69 ng/mL for CCSG, 1.70–54.5 ng/mL for ononin, 1.85–59.06 ng/mL for calycosin, 2.14–137.24 ng/mL for DPPG and1.96–125.25 ng/mL for DIFG, respectively. The method had the lower limit of quantification (LLOQ) with 0.49, 0.21, 0.92, 1.07, and 0.98 ng/mL for CCSG, ononin, calycosin, DPPG and DIFG respectively, and the precision less than 10%. The RSD of the accuracy was in the range of −4.35–8.91%. The results may be helpful to provide more accurate references to clinical application of this herb.