Numerical and Experimental Investigations of Different Cross-Sectional Configuration of Plain Concrete and CFST Short Columns Under Axial Compression

2019 ◽  
Vol 17 (10) ◽  
pp. 1585-1601 ◽  
Author(s):  
Palash Dey ◽  
R. K. Gupta ◽  
A. I. Laskar
2021 ◽  
Vol 1203 (2) ◽  
pp. 022037
Author(s):  
Mungur Ved Vritesh ◽  
Seeboo Asish

Abstract In the construction industry, there are several methods which have been used to improve the capacity and effectiveness of structural concrete structures. Engineers can extend the life of the structures by implementing strengthening techniques. One of the techniques to strengthen columns and beams is the use of jacketing. The strength of the structural members is enhanced through the surface structural bonding of materials such as Carbon-Fibre Reinforced Polymer (CFRP), Glass-Fibre Reinforced Polymer (GFRP), ferrocement, steel angles, steel plates, wire mesh and so on. In this study, 18 reinforced concrete short columns of cross-sectional size 60 mm × 60 mm and 500 mm height were cast using concrete grade 30 MPa. The columns were subjected to compressive axial loads till failure. Moreover, the damaged columns were strengthened using three structural strengthening techniques namely, Reinforced Concrete Jacketing (RCJ), Reinforced Concrete Wire Mesh Jacketing (RCWJ) and, Steel Jacketing (SJ). The columns strengthened using RCJ and RCWJ had a cross section of 120 mm × 120 mm while SJ had a cross section of 66 mm × 66 mm. Six different configurations were used for each technique. The experimental investigations showed a minimum increase of 48.0%, 48.7% and 35.2% in the axial compressive strength when strengthened using RCJ, RCWJ and SJ respectively. Among the three strengthening techniques, SJ was determined to be the effective technique on considering structural design, time production and costs.


2020 ◽  
Author(s):  
T. Siva Sai Hoshitha ◽  
T. Chandrasekhar Rao ◽  
T. D. Gunneswara Rao

Structures ◽  
2021 ◽  
Vol 32 ◽  
pp. 1374-1385
Author(s):  
Mizan Ahmed ◽  
Junchang Ci ◽  
Xi-Feng Yan ◽  
Shicai Chen

Water ◽  
2018 ◽  
Vol 10 (9) ◽  
pp. 1166 ◽  
Author(s):  
Łukasz Przyborowski ◽  
Anna Łoboda ◽  
Robert Bialik

Long-duration measurements were performed in two sandy bed rivers, and three-dimensional (3D) flow velocity and bottom elevation changes were measured in a vegetated area and in a clear region of a river. Detailed flow velocity profiles downstream and upstream of a single specimen of Potamogeton pectinatus L. were obtained and the bed morphology was assessed. Potamogeton plants gathered from each river were subjected to tensile and bending tests. The results show that the existence of the plants was influenced by both bottom and flow conditions, as the plants were located where water velocity was lower by 12% to 16% in comparison to clear region. The characteristics of the flow and sand forms depended on the cross-sectional arrangement of the river, e.g., dunes were approximately four times higher in the middle of the river than in vegetated regions near the bank. Furthermore, the studied hydrophytes were too sparse to affect water flow and had no discernible impact on the sand forms’ movements. The turbulent kinetic energy downstream of a single plant was reduced by approximately 25%. Additionally, the plants’ biomechanical characteristics and morphology were found to have adjusted to match the river conditions.


2021 ◽  
Vol 15 (58) ◽  
pp. 77-85
Author(s):  
Amor Bouaricha ◽  
Naoual Handel ◽  
Aziza Boutouta ◽  
Sarah Djouimaa

In this experimental work, strength results obtained on short columns subjected to concentric loads are presented. The specimens used in the tests have made of cold-rolled, thin-walled steel. Twenty short columns of the same cross-section area and wall thickness have been tested as follows: 8 empty and 12 filled with ordinary concrete. In the aim to determine the column section geometry with the highest resistance, three different types of cross-sections have been compared: rectangular, I-shaped unreinforced and, reinforced with 100 mm spaced transversal links. The parameters studied are the specimen height and the cross-sectional steel geometry. The registered experimental results have been compared to the ultimate loads intended by Eurocode 3 for empty columns and by Eurocode 4 for compound columns. These results showed that a concrete-filled composite column had improved strength compared to the empty case. Among the three cross-section types, it has been found that I-section reinforced is the most resistant than the other two sections. Moreover, the load capacity and mode of failure have been influenced by the height of the column. Also, it had noted that the experimental strengths of the tested columns don’t agree well with the EC3 and EC4 results.


Sign in / Sign up