Pseudo Color Fusion of Infrared and Visible Images Based on the Rattlesnake Vision Imaging System

Author(s):  
Yong Wang ◽  
Hongqi Liu ◽  
Xiaoguang Wang
2011 ◽  
Vol 135-136 ◽  
pp. 983-988
Author(s):  
Na Ding ◽  
Jiao Bo Gao ◽  
Jun Wang

In this paper, we developed an infrared polarization imaging system. The system is composed of imaging lens, IR polarizing filter, medium wave IR detector, and image acquisition system. The design scheme of implementing target recognition with IR polarization imaging system was presented, and the IR Images with polarization information have been acquired by this system. On the basis of Stokes parameters and polarization IR images processing, the images of linear Stokes parameters (I, Q, U), the image of degree of linear polarization (P image) and the image of angle of polarization (X image) could been obtained. The image of PUX fusion image could be achieved by the pseudo color fusion. The results of actual experiment and quantitative analysis data confirm that the target in the processed images obtained from IR polarization imaging system is much clear than that in the original IR image.


2011 ◽  
Vol 135-136 ◽  
pp. 341-346
Author(s):  
Na Ding ◽  
Jiao Bo Gao ◽  
Jun Wang

A novel system of implementing target identification with hyperspectral imaging system based on acousto-optic tunable filter (AOTF) was proposed. The system consists of lens, AOTF, AOTF driver, CCD and image collection installation. Owing to the high spatial and spectral resolution, the system can operate in the spectral range from visible light to near infrared band. An experiment of detecting and recognizing of two different kinds of camouflage armets from background was presented. When the characteristic spectral wave bands are 680nm and 750nm, the two camouflage armets exhibit different spectral characteristic. The target camouflage armets in the hyperspectral images are distinct from background and the contrast of armets and background is increased. The image fusion, target segmentation and pick-up of those images with especial spectral characteristics were realized by the Hyperspectral Imaging System. The 600nm, 680nm, and 750nm images were processed by the Pseudo color fusion algorithm, thus the camouflage armets are more easily observed by naked eyes. Experimental results confirm that AOTF hyperspectral imaging system can acquire image of high contrast, and has the ability of detecting and identification camouflage objects.


2012 ◽  
Vol 433-440 ◽  
pp. 5436-5442
Author(s):  
Lei Li

The pseudo-color processing for target identification and tracking is very meaningful Experimental results show that the pseudo-color image fusion is a very effective methods. This paper presents a false color image fusion based on the new method. Fusion using wavelet transform grayscale images, find the gray fused image and the difference between the original image, respectively, as the image of l, α, β components are color fusion image, and then after the color transformation, the final false color fused image. The results showed that the color fusion image colors more vivid, more in line with human visual characteristics.


Author(s):  
Willem H.J. Andersen

Electron microscope design, and particularly the design of the imaging system, has reached a high degree of perfection. Present objective lenses perform up to their theoretical limit, while the whole imaging system, consisting of three or four lenses, provides very wide ranges of magnification and diffraction camera length with virtually no distortion of the image. Evolution of the electron microscope in to a routine research tool in which objects of steadily increasing thickness are investigated, has made it necessary for the designer to pay special attention to the chromatic aberrations of the magnification system (as distinct from the chromatic aberration of the objective lens). These chromatic aberrations cause edge un-sharpness of the image due to electrons which have suffered energy losses in the object.There exist two kinds of chromatic aberration of the magnification system; the chromatic change of magnification, characterized by the coefficient Cm, and the chromatic change of rotation given by Cp.


Author(s):  
G. Botton ◽  
G. L’Espérance ◽  
M.D. Ball ◽  
C.E. Gallerneault

The recently developed parallel electron energy loss spectrometers (PEELS) have led to a significant reduction in spectrum acquisition time making EELS more useful in many applications in material science. Dwell times as short as 50 msec per spectrum with a PEELS coupled to a scanning transmission electron microscope (STEM), can make quantitative EEL images accessible. These images would present distribution of elements with the high spatial resolution inherent to EELS. The aim of this paper is to briefly investigate the effect of acquisition time per pixel on the signal to noise ratio (SNR), the effect of thickness variation and crystallography and finally the energy stability of spectra when acquired in the scanning mode during long periods of time.The configuration of the imaging system is the following: a Gatan PEELS is coupled to a CM30 (TEM/STEM) electron microscope, the control of the spectrometer and microscope is performed through a LINK AN10-85S MCA which is interfaced to a IBM RT 125 (running under AIX) via a DR11W line.


Author(s):  
E. D. Salmon ◽  
J. C. Waters ◽  
C. Waterman-Storer

We have developed a multi-mode digital imaging system which acquires images with a cooled CCD camera (Figure 1). A multiple band pass dichromatic mirror and robotically controlled filter wheels provide wavelength selection for epi-fluorescence. Shutters select illumination either by epi-fluorescence or by transmitted light for phase contrast or DIC. Many of our experiments involve investigations of spindle assembly dynamics and chromosome movements in live cells or unfixed reconstituted preparations in vitro in which photodamage and phototoxicity are major concerns. As a consequence, a major factor in the design was optical efficiency: achieving the highest image quality with the least number of illumination photons. This principle applies to both epi-fluorescence and transmitted light imaging modes. In living cells and extracts, microtubules are visualized using X-rhodamine labeled tubulin. Photoactivation of C2CF-fluorescein labeled tubulin is used to locally mark microtubules in studies of microtubule dynamics and translocation. Chromosomes are labeled with DAPI or Hoechst DNA intercalating dyes.


Author(s):  
C. A. Callender ◽  
Wm. C. Dawson ◽  
J. J. Funk

The geometric structure of pore space in some carbonate rocks can be correlated with petrophysical measurements by quantitatively analyzing binaries generated from SEM images. Reservoirs with similar porosities can have markedly different permeabilities. Image analysis identifies which characteristics of a rock are responsible for the permeability differences. Imaging data can explain unusual fluid flow patterns which, in turn, can improve production simulation models.Analytical SchemeOur sample suite consists of 30 Middle East carbonates having porosities ranging from 21 to 28% and permeabilities from 92 to 2153 md. Engineering tests reveal the lack of a consistent (predictable) relationship between porosity and permeability (Fig. 1). Finely polished thin sections were studied petrographically to determine rock texture. The studied thin sections represent four petrographically distinct carbonate rock types ranging from compacted, poorly-sorted, dolomitized, intraclastic grainstones to well-sorted, foraminiferal,ooid, peloidal grainstones. The samples were analyzed for pore structure by a Tracor Northern 5500 IPP 5B/80 image analyzer and a 80386 microprocessor-based imaging system. Between 30 and 50 SEM-generated backscattered electron images (frames) were collected per thin section. Binaries were created from the gray level that represents the pore space. Calculated values were averaged and the data analyzed to determine which geological pore structure characteristics actually affect permeability.


Sign in / Sign up

Export Citation Format

Share Document