One-step sandwich enzyme-linked immunosorbent assay of human tissue plasminogen activator using monoclonal antibodies

1985 ◽  
Vol 40 (1) ◽  
pp. 91-99 ◽  
Author(s):  
Tsutomu Kaizu ◽  
Kayoko Kojima ◽  
Kaori Iwasaki ◽  
Tatsuo Yamashita
1985 ◽  
Vol 54 (03) ◽  
pp. 684-687 ◽  
Author(s):  
Paul Holvoet ◽  
Hugo Cleemput ◽  
Désiré Collen

SummaryAn enzyme-linked immunosorbent assay (ELISA) for the measurement of human tissue-type plasminogen activator (t-PA) was developed. Microtiter plates were coated with a mixture of two monoclonal antibodies and bound t-PA was quantitated with a third monoclonal antibody linked to peroxidase. The lower limit of sensitivity of the assay was 0.2 ng of t-PA per ml. The concentration of antigen in citrated plasma of human subjects was found to be 3.4 ± 0.8 ng/ml. The assay had a good reproducibility with values of 3.8, 6.5 and 4.9 percent respectively for the intra-, inter-assay and inter-dilution variation coefficients. The results of the ELISA assay on plasma samples from patients during thrombolytic therapy with t-PA correlated very well, over a wide concentration range, with those obtained with a previously described two-site immuno-radiometric assay (r = 0.96). This ELISA with monoclonal antibodies constitutes a stable and reproducible set of reagents for the measurement of t-PA antigen in biological fluids, avoiding the disadvantages of the use of radioisotopes and of polyclonal antibodies.


VASA ◽  
2014 ◽  
Vol 43 (6) ◽  
pp. 450-458 ◽  
Author(s):  
Julio Flores ◽  
Ángel García-Avello ◽  
Esther Alonso ◽  
Antonio Ruíz ◽  
Olga Navarrete ◽  
...  

Background: We evaluated the diagnostic efficacy of tissue plasminogen activator (tPA), using an enzyme-linked immunosorbent assay (ELISA) and compared it with an ELISA D-dimer (VIDAS D-dimer) in acute pulmonary embolism (PE). Patients and methods: We studied 127 consecutive outpatients with clinically suspected PE. The diagnosis of PE was based on a clinical probability pretest for PE and a strict protocol of imaging studies. A plasma sample to measure the levels of tPA and D-dimer was obtained at enrollment. Diagnostic accuracy for tPA and D-dimer was determined by the area under the receiver operating characteristic (ROC) curve. Sensitivity, specificity, predictive values, and the diagnostic utility of tPA with a cutoff of 8.5 ng/mL and D-dimer with a cutoff of 500 ng/mL, were calculated for PE diagnosis. Results: PE was confirmed in 41 patients (32 %). Areas under ROC curves were 0.86 for D-dimer and 0.71 for tPA. The sensitivity/negative predictive value for D-dimer using a cutoff of 500 ng/mL, and tPA using a cutoff of 8.5 ng/mL, were 95 % (95 % CI, 88–100 %)/95 % (95 % CI, 88–100 %) and 95 % (95 % CI, 88–100 %)/94 %), respectively. The diagnostic utility to exclude PE was 28.3 % (95 % CI, 21–37 %) for D-dimer and 24.4 % (95 % CI, 17–33 %) for tPA. Conclusions: The tPA with a cutoff of 8.5 ng/mL has a high sensitivity and negative predictive value for exclusion of PE, similar to those observed for the VIDAS D-dimer with a cutoff of 500 ng/mL, although the diagnostic utility was slightly higher for the D-dimer.


1989 ◽  
Vol 61 (03) ◽  
pp. 409-414 ◽  
Author(s):  
M Rånby ◽  
G Nguyen ◽  
P Y Scarabin ◽  
M Samama

SummaryAn enzyme linked immunosorbent assay (ELISA) based on goat polyclonal antibodies against human tissue plasminogen activator (tPA) was evaluated. The relative immunoreactivity of tPA in free form and tPA in complex with inhibitors was estimated by ELISA and found to be 100, 74, 94, 92 and 8l% for free tPA and tPA in complex with PAI-1, PAI-2, α2-antiplasmin and C1-inhibitor, respectively. Addition of tPA to PAI-1 rich plasma resulted in rapid and total loss of tPA activity without detectable loss of ELISA response, indicating an immunoreactivity of tPA in tPA/PAI-1 complex of about l00%. Three different treatments of citrated plasma samples (acidification/reneutralization, addition of 5 mM EDTA or of 0.5 M lysine) prior to determination by ELISA all resulted in increased tPA levels. The fact that the increase was equally large in all three cases along with good analytical recovery of tPA added to plasffi, supported the notion that all tPA antigen present in plasma samples is measured by the ELISA. Analysis by ELISA of fractions obtained by gel filtration of plasma from a patient undergoing tPA treatment identified tPA/inhibitor complexes and free tPA but no low molecular weight degradation products of tPA. Determinations of tPA antigen were made at seven French clinical laboratories on coded and randomized plasma samples with known tPA antigen content. For undiluted samples there was no significant difference between the tPA levels found and those known to be present. The between-assay coefficient of variation was 7 to 10%. In conclusion, the ELISA appeared suited for determination of total tPA antigen in human plasma samples.


1983 ◽  
Vol 50 (03) ◽  
pp. 740-744 ◽  
Author(s):  
Nils Bergsdorf ◽  
Torbjörn Nilsson ◽  
Per Wallén

SummaryUtilizing the immunoglobulin fraction from a goat antiserum against human uterine tissue plasminogen activator, an enzyme- linked immunoassay for tissue-type plasminogen activator in human plasma has been developed. With the new method, the concentration of t-PA in normal human acidified plasma is found to be 4.0 ± 1.8 (SD) ng/ml. It increases to 12 ng/ml after a tomiquet test, and to 14 ng/ml after strenous physical exercise. In a group of patients with idiopathic thromboembolic disease, the resting t-PA concentration was 5 ng/ml and the post-occlusion value 16 ng/ml. Furthermore, the patients also exhibited a normal post-occlusion rise in the concentration of plasmin-α2-antiplasmin complex. However, in 37% of the post-occlusion patient plasmas, virtually no increase in t-PA could be detected by a specific activity assay. The results indicate that the reason for a defective post-occlusion fibrinolytic activity in a majority of cases may be the presence of increased concentrations of a fast-acting specific t-PA inhibitor.


Sign in / Sign up

Export Citation Format

Share Document