The electroplated Pd–Co alloy film on 316L stainless steel and the corrosion resistance in boiling acetic acid and formic acid mixture with stirring

2014 ◽  
Vol 321 ◽  
pp. 179-187 ◽  
Author(s):  
Sirui Li ◽  
Yu Zuo ◽  
Yuming Tang ◽  
Xuhui Zhao
Alloy Digest ◽  
1995 ◽  
Vol 44 (6) ◽  

Abstract BioDur 316LS stainless steel is a modified version of Type 316L stainless steel to improve corrosion resistance for surgical implant applications. The alloy is vacuum arc remelted. This datasheet provides information on composition, physical properties, hardness, and tensile properties. It also includes information on corrosion resistance as well as forming, heat treating, machining, and joining. Filing Code: SS-596. Producer or source: Carpenter.


Alloy Digest ◽  
2015 ◽  
Vol 64 (7) ◽  

Abstract EnduraMet 316LN stainless is a nitrogen strengthened version of Type 316L stainless steel. This datasheet provides information on composition, physical properties, and tensile properties as well as fracture toughness. It also includes information on corrosion resistance as well as forming, heat treating, machining, and joining. Filing Code: SS-1219. Producer or source: Carpenter Technology Corporation.


Author(s):  
S. Kuroda ◽  
T. Fukushima ◽  
T. Kodama ◽  
M. Sasaki

Abstract 316L stainless steel and Hastelloy C alloy powders were sprayed by an HVOF apparatus onto mild steel substrates. The microstructure, pore size distribution, composition and corrosion resistance of thus obtained coatings were evaluated experimentally. Corrosion resistance in sea-water was examined by monitoring the impedance and corrosion potential of samples immersed in artificial sea-water at 300 K over a period of more than 3 months and also by polarization measurement. It was found that the stainless coatings composed mainly of plastically deformed particles and some splats which were molten at the impact. By increasing the combustion pressure, the porosity as measured by mercury porosimeter could be reduced to below 1%. In comparison, Hastelloy C deposits sprayed under the standard condition were so dense that its porosity could not be measured by the porosimeter. The polarization curve and the results of impedance monitoring both exemplified that the Hastelloy C coatings possess much superior corrosion resistance to the stainless coatings in sea-water, which was attributed to the higher density and better adhesion of the Ni-base alloy coatings.


Materials ◽  
2021 ◽  
Vol 14 (22) ◽  
pp. 6790
Author(s):  
Viera Zatkalíková ◽  
Juraj Halanda ◽  
Dušan Vaňa ◽  
Milan Uhríčik ◽  
Lenka Markovičová ◽  
...  

Plasma immersion ion implantation (PIII) of nitrogen is low-temperature surface technology which enables the improvement of tribological properties without a deterioration of the corrosion behavior of austenitic stainless steels. In this paper the corrosion properties of PIII-treated AISI 316L stainless steel surfaces are evaluated by electrochemical impedance spectroscopy (EIS), potentiodynamic polarization (PP) and exposure immersion tests (all carried out in the 0.9 wt. % NaCl solution at 37 ± 0.5 °C) and compared with a non-treated surface. Results of the three performed independent corrosion tests consistently confirmed a significant increase in the corrosion resistance after two doses of PIII nitriding.


2022 ◽  
Vol 60 (1) ◽  
pp. 46-52
Author(s):  
Young Woo Seo ◽  
Chan Yang Kim ◽  
Bo Kyung Seo ◽  
Won Sub Chung

This study evaluated changes in delta-ferrite content depending on the preheating of AISI 316L stainless steel. We also determined the reasons for the variation in delta-ferrite content, which affects corrosion resistance. Changes in delta-ferrite content after preheating was confirmed using a Feritscope, and the microstructure was analyzed using optical microscopy (OM). We found that the delta-ferrite microstructure size decreased when preheating time was increased at 1295 oC, and that the delta-ferrite content could be controlled through preheating. Potentiodynamic polarization test were carried out in NaCl (0.5 M) + H2SO4 (0.5 M) solution, and it was found that higher delta-ferrite content resulted in less corrosion potential and passive potential. To determine the cause, an analysis was conducted using energy-dispersive spectroscopy (EDS), which confirmed that higher delta-ferrite content led to weaker corrosion resistance, due to Cr degradation at the delta-ferrite and austenite boundaries. The degradation of Cr on the boundaries between austenite and delta-ferrite can be explained by the difference in the diffusion coefficient of Cr in the ferrite and austenite. A scanning electron microscopy (SEM) analysis of material used for actual semiconductor piping confirmed that corrosion begins at the delta-ferrite and austenite boundaries. These results confirm the need to control delta-ferrite content in AISI 316L stainless steel used for semiconductor piping.


1991 ◽  
Vol 49 (1-3) ◽  
pp. 83-86 ◽  
Author(s):  
J.H. Hsieh ◽  
R. Lee ◽  
R.A. Erck ◽  
G.R. Fenske ◽  
Y.Y. Su ◽  
...  

CORROSION ◽  
10.5006/3759 ◽  
2021 ◽  
Author(s):  
Yanli Wang ◽  
Ping Wang ◽  
Changxuan Wang ◽  
Shenghua Zhang

A Cr2O3 diffusion barrier was in-situ formed between Ni coating and 316L through electroplating a Ni(NiO) transition layer firstly and then annealing at 900 °C for 8 h in Ar. The obtained Cr2O3 is dense, continuously grown and well-bonded with 316L. The diffusion and corrosion resistance of Ni coating with and without Cr2O3 diffusion barrier were investigated. No visible outer diffusion of elements was found during the heat treatment at 750 °C for 150 h and the Ni coating with a Cr2O3 diffusion barrier can provide a good protection for 316L in molten (Li,Na,K)F.


Sign in / Sign up

Export Citation Format

Share Document