Performances and mechanisms of simultaneous nitrate and phosphate removal in sponge iron biofilter

2021 ◽  
pp. 125390
Author(s):  
Jianmin Li ◽  
Wei Zeng ◽  
Hong Liu ◽  
Yuexi Wu ◽  
HaoHao Miao
2013 ◽  
Vol 12 (12) ◽  
pp. 2371-2383
Author(s):  
Krishnaswamy Usharani ◽  
Perumalsamy Lakshmanaperumalsamy ◽  
Muthusamy Muthukumar

1975 ◽  
Vol 10 (1) ◽  
pp. 214-223
Author(s):  
N.S. Wei ◽  
G.W. Heinke

Abstract This paper presents bench scale experimental results on the electrolysis of raw domestic wastewater. Studies carried out with consumable electrodes are discussed. A mathematical model of a small electrolytic sewage treatment unit for individual household application is developed. The energy consumption and cost of such a device are discussed. Electrolysis can be described as a process in which chemical reactions are induced at each electro-liquid interface by applying an external electrical energy source to a system of electrodes immersed in a liquid. This paper deals only with electrolysis where a direct current power supply is used as the energy source. The process is governed by Faraday' s two laws on electrochemistry. The fundamental process parameter is the electrical charge density, measured as coulombs per litre (c/1) of wastewater treated. There are two basic types of electrolysis depending on the choice of anode material. When the anode is made of dissolvable metallic material such as iron, stainless steel and aluminum, the metal dissolves and goes into the sewage as metallic ions and forms hydrated metallic oxides which act as flocculating agents. The amount of metal dissolved is proportional to the quantity of electrical charges supplied to the system. Results from a series of batch experiments showed that electrolysis with consumable electrodes is capable of removing significant amounts of organic pollutants. Total organic carbon (TOC) removal was found to be a function of charge density. Phosphate removal efficiency of 90 percent or higher was achieved at a relatively low charge density of 240 coulombs per litre with either iron or stainless steel anodes. A mathematical model was derived in the conceptual design of a household electrolytic treatment unit. The model incorporates variables such as decomposition voltage of the electrodes and electrical conductivity of the wastewater as well as the physical configuration of the electrolytic cell. The energy requirement of such a unit can be calculated from the model. It is suggested in this paper that an electrolytic waste treatment unit could be an alternative to the septic tank and tile bed system in areas where the latter is not applicable due to poor soil and terrain conditions.


1991 ◽  
Vol 24 (10) ◽  
pp. 329-332
Author(s):  
P. M. J. Janssen ◽  
J. H. Rensink ◽  
E. Eggers
Keyword(s):  

1994 ◽  
Vol 30 (6) ◽  
pp. 237-246 ◽  
Author(s):  
A. Carucci ◽  
M. Majone ◽  
R. Ramadori ◽  
S. Rossetti

This paper describes a lab-scale experimentation carried out to study enhanced biological phosphate removal (EBPR) in a sequencing batch reactor (SBR). The synthetic feed used was based on peptone and glucose as organic substrate to simulate the readily biodegradable fraction of a municipal wastewater (Wentzel et al., 1991). The experimental work was divided into two runs, each characterized by different operating conditions. The phosphorus removal efficiency was considerably higher in the absence of competition for organic substrate between P-accumulating and denitrifying bacteria. The activated sludge consisted mainly of peculiar microorganisms recently described by Cech and Hartman (1990) and called “G bacteria”. The results obtained seem to be inconsistent with the general assumption that the G bacteria are characterized by anaerobic substrate uptake not connected with any polyphosphate metabolism. Supplementary anaerobic batch tests utilizing glucose, peptone and acetate as organic substrates show that the role of acetate in the biochemical mechanisms promoting EBPR may not be so essential as it has been assumed till now.


1992 ◽  
Vol 25 (4-5) ◽  
pp. 203-209 ◽  
Author(s):  
R. Kayser ◽  
G. Stobbe ◽  
M. Werner

At Wolfsburg for a load of 100,000 p.e., the step-feed activated sludge process for nitrogen removal is successfully in operation. Due to the high denitrification potential (BOD:TKN = 5:1) the effluent total nitrogen content can be kept below 10 mg l−1 N; furthermore by some enhanced biological phosphate removal about 80% phosphorus may be removed without any chemicals.


1998 ◽  
Vol 37 (4-5) ◽  
pp. 281-289 ◽  
Author(s):  
Dick H. Eikelboom ◽  
Andreas Andreadakis ◽  
Kjaer Andreasen

A joint EU research project aimed at solving activated sludge bulking in nutrient removal plants was initiated in 1993. The project started with a survey of the size and composition of the filamentous population in nutrient removal plants in Denmark, Germany, Greece and the Netherlands. The results show that biological nutrient removal process conditions indeed favour filamentous microorganisms in their competition with floc forming organisms. An increase in the size of the filamentous population resulted in a deterioration of the settling properties of the biomass, except for plants with Bio-P removal conditions. It is assumed that in the latter case the dense clusters of Bio-P bacteria increase the weight of the flocs, and compensate for the effect of the larger number of filaments. Although exceptions frequently occur, the following sequence in decreasing filamentous organism population size was observed for the process conditions indicated: - completely mixed + simultaneous denitrification; - completely mixed + intermittent aeration/denitrification; - alternating anoxic/oxic process conditions, with an anaerobic tank for biological phosphate removal (Bio-Denipho); - alternating anoxic/oxic process conditions (Bio-Denitro); - predenitrification The surveys provided little information about the effect of nutrient removal in plants with plug flow aeration basins. Simultaneous precipitation with aluminium salts nearly always resulted in a low number of filaments and a good settling sludge. The size of the filamentous organism population showed a seasonal pattern with a maximum in winter/early spring and a minimum during summer (in Greece: during autumn). This seasonal variation is primarily caused by the effect of the season on the population sizes of M. parvicella, N. limicola and Type 0092. M. parvicella is by far the most important filamentous species in nutrient removal plants. In Denmark only, Type 0041 also frequently dominates the filamentous population, but seldom causes severe bulking. Considering their frequency of occurrence, approx. 10 other filamentous micro-organisms are of minor importance. Growth of some of these species, viz. those which use soluble substrate, can be prevented by the introduction of Bio-P process conditions. M. parvicella and Type 0041 (and probably also Actinomycetes and the Types 1851 and 0092) seem to compete for the same substrates i.e. the influent particulate fraction. Most of the differences in composition of the filamentous microorganism population can be explained by whether or not premixing of influent and recycled sludge is used. In general, premixing for a short period of time followed by anoxic conditions favours Type 0041. M. parvicella seems to proliferate if the particulate fraction is first hydrolysed or if it enters the plant via an oxic zone. It is concluded that bulking in nutrient removal plants is mainly caused by filamentous species requiring the particulate fraction for their growth.


1997 ◽  
Vol 36 (6-7) ◽  
pp. 191-200 ◽  
Author(s):  
C. M. Carliell ◽  
A. D. Wheatley

Chemical extraction methods are used to investigate metal and phosphate speciation during anaerobic digestion of phosphorus-rich sludge. Tests were performed using model compounds to evaluate the efficacy of the reagents in the extraction sequences and these results compared with similar work by other researchers. The metal speciation method was found to be suitable for identifying shifts in metal distribution but was unrepresentative of actual metal species. The phosphate speciation method did give adequate separation of the phosphate compounds tested. Full-scale digesters treating chemical and biological phosphate removal (CPR and BPR) sludge were analysed according to the methods developed. Results show that digestion of CPR sludge did not increase the soluble P concentration in the digester and that most of the precipitated phosphorus appeared to be retained in the sludge as inorganic P. The digester treating BPR sludge showed increased soluble and water-extractable P, in comparison to the control digester. Trace metal speciation profiles were found to be affected by addition of CPR sludge.


Sign in / Sign up

Export Citation Format

Share Document