scholarly journals Soft stimulation treatment of geothermal well RV-43 to meet the growing heat demand of Reykjavik

Geothermics ◽  
2021 ◽  
Vol 96 ◽  
pp. 102146
Author(s):  
Hannes Hofmann ◽  
Günter Zimmermann ◽  
Ernst Huenges ◽  
Simona Regenspurg ◽  
Santiago Aldaz ◽  
...  
Keyword(s):  
Energies ◽  
2020 ◽  
Vol 14 (1) ◽  
pp. 35
Author(s):  
Elżbieta Szostak ◽  
Piotr Duda ◽  
Andrzej Duda ◽  
Natalia Górska ◽  
Arkadiusz Fenicki ◽  
...  

Although Poland is one of the leading recipients of the waste stream in the European Union (EU), it is at the same time below the average in terms of efficiency of their use/utilization. The adopted technological solutions cause waste processing rates to be relatively low in Poland. As a result, the report of the Early Warning and Response System (EWRS) of the EU indicated Poland as one of the 14 countries of the EU which are at risk in terms of possibility of achieving 50% recycling of waste. This article discusses the implemented technological solutions, and shows the profitability of the investment and the values of the process heat demand both for extractor and reactor. The experimental part analyzed the composition of the input and output of the process and compared it to the required fuel specifications. Attention was drawn to the need to improve the recycling process in order to increase the quality of manufactured fuel components. As potential ways of solving the problem of low fuel quality, cleaning the sorted reaction mass from solid particles and extending the technological line with a distillation column have been proposed. The recommended direction of improvement of the technology is also the optimization of the process of the reactor’s purification and removal of contaminants.


Energy ◽  
2021 ◽  
pp. 120784
Author(s):  
Elisabeth Zeyen ◽  
Veit Hagenmeyer ◽  
Tom Brown
Keyword(s):  

Energies ◽  
2021 ◽  
Vol 14 (13) ◽  
pp. 3731
Author(s):  
Simon Kamerling ◽  
Valéry Vuillerme ◽  
Sylvain Rodat

Using solar power for industrial process heat is an increasing trend to fight against climate change thanks to renewable heat. Process heat demand and solar flux can both present intermittency issues in industrial systems, therefore solar systems with storage introduce a degree of freedom on which optimization, on a mathematical basis, can be performed. As the efficiency of solar thermal receivers varies as a function of temperature and solar flux, it seems natural to consider an optimization on the operating temperature of the solar field. In this paper, a Mixed Integer Linear Programming (MILP) algorithm is developed to optimize the operating temperature in a system consisting of a concentrated solar thermal field with storage, hybridized with a boiler. The MILP algorithm optimizes the control trajectory on a time horizon of 48 h in order to minimize boiler use. Objective function corresponds to the boiler use, for completion of the heat from the solar field, whereas the linear constraints are a simplified representation of the system. The solar field mass flow rate is the optimization variable which is directly linked to the outlet temperature of the solar field. The control trajectory consists of the solar field mass flow rate and outlet temperature, along with the auxiliary mass flow rate going directly to the boiler. The control trajectory is then injected in a 0D model of the plant which performs more detailed calculations. For the purpose of the study, a Linear Fresnel system is investigated, with generic heat demand curves and constant temperature demand. The value of the developed algorithm is compared with two other control approaches: one operating at the nominal solar field output temperature, and the other one operating at the actual demand mass flow rate. Finally, a case study and a sensitivity analysis are presented. The MILP’s control shows to be more performant, up to a relative increase of the annual solar fraction of 4% at 350 °C process temperature. Novelty of this work resides in the MILP optimization of temperature levels presenting high non-linearities, applied to a solar thermal system with storage for process heat applications.


2016 ◽  
Vol 5 (12) ◽  
pp. 219 ◽  
Author(s):  
Tobias Törnros ◽  
Bernd Resch ◽  
Matthias Rupp ◽  
Hartmut Gündra

2003 ◽  
Vol 15 (1) ◽  
pp. 35-44 ◽  
Author(s):  
T. Sugama ◽  
L. E. Brothers ◽  
L. Weber
Keyword(s):  

Author(s):  
Kevin D. Woods ◽  
Alfonso Ortega

Heat pumps are mechanical systems that provide heating to a space in the winter, and cooling in the summer. They are increasingly popular because the same system provides both cooling modes, depending on the direction of the cycle upon which they operate. For proper operation, the heat pump must be connected to a constant temperature thermal reservoir which in traditional systems is the ambient air. In ground source heat pumps however, subterranean ground water is used as the thermal reservoir. To access the subterranean groundwater, “geothermal” wells are drilled into the formation. Water from the building heating or cooling system is circulated through the wells thereby promoting heat exchange between the coolant water and the subterranean formation. The potential for higher efficiency heating and cooling has increased the utilization of ground source heating ventilating and air conditioning systems. In addition, their compatibility with a naturally occurring and stable thermal reservoir has increased their use in the design of sustainable or green buildings and man-made environments. Groundwater flow affects the temperature response of thermal wells due to advection of heat by physical movement of groundwater through the aquifer. Research on this subject is scarce in the geothermal literature. This paper presents the derivation of an analytical solution for thermal dispersion by conduction and advection from hydraulic groundwater flow for a “geothermal” well. This analytical solution is validated against asymptotic analytical solutions. The traditional constant linear heat source solution is dependent on the ground formation thermal properties; the most dominant of which is the thermal conductivity. The results show that as hydraulic groundwater flow increases, the influence of the ground formation thermal conductivity on the temperature response of the well diminishes. The diminishing influence is evident in the Peclet number parameter; a comparison of thermal advection from hydraulic groundwater flow to thermal conduction by molecular diffusion.


1994 ◽  
Vol 27 (2) ◽  
pp. 188-193 ◽  
Author(s):  
Damrong Pradubsripetch ◽  
Yuji Naka ◽  
Zhang Fan

PEDIATRICS ◽  
1984 ◽  
Vol 74 (6) ◽  
pp. 1022-1028
Author(s):  
Stephen Baumgart

Eight very low-birth-weight premature infants (mean birth weight 1.11 ± 0.05 [SEM] kg, mean gestation 30 ± 1 weeks, and mean age 9 ± 2 days) were studied under servocontrolled radiant warmers with and without a loosely fitted, transparent, and flexible Saran plastic blanket. Metabolic rate was significantly less in all infants when covered by the blanket (oxygen consumption was 7.99 ± 1.13 mL/kg/min v 9.00 ± 1.10 mL/kg/min uncovered, P < .001). There were also significant reductions in insensible water loss (1.86 ± 0.18 v 1.25 ± 0.20 mL/kg/h, P < .01) and in heat demand from the radiant warmer (14.3 ± 1.3 v 9.9 ± 1.4 mW/cm2, P < .001) when infants were nursed under the blanket compared with the control condition, respectively. Covering the critically ill, very low-birth-weight infant nursed under a radiant heater with a thin, transparent layer of Saran is beneficial in reducing oxygen consumption, insensible water loss, and the need for exposure to high levels of radiant heat. Further investigation to confirm the benefits and possible complications of plastic blankets should be conducted before routine use can be recommended.


2021 ◽  
Author(s):  
Junichi Sugiura ◽  
Ramon Lopez ◽  
Francisco Borjas ◽  
Steve Jones ◽  
John McLennan ◽  
...  

Abstract Geothermal energy is used in more than 20 countries worldwide and is a clean, reliable, and relatively available energy source. Nevertheless, to make geothermal energy available anywhere in the world, technical and economic challenges need to be addressed. Drilling especially is a technical challenge and comprises a significant part of the geothermal development cost. An enhanced geothermal system (EGS) is a commercially viable thermal reservoir where two wells are interconnected by some form of hydraulic stimulation. In a commercial setting, fluid is injected into this hot rock and passes between wells through a network of natural and induced fractures to transport heat to the surface system for electricity generation. To construct EGS wells, vertical and directional drilling is necessary with purpose-built drilling and steering equipment. This is an application where oil-and-gas drilling tools and techniques can be applied. A recent well, 16A(78)-32, drilled as part of the US Department of Energy's (DOE's) Utah Frontier Observatory for Research in Geothermal Energy (FORGE) program, highlights some of the technical challenges, which include drilling an accurate vertical section, a curve section, and a 5300-ft 65° tangent section in a hard granitic formation at temperatures up to 450°F (232°C). Extensive downhole temperature simulations were performed to select fit-for-purpose drilling equipment such as purely mechanical vertical drilling tools, instrumented steerable downhole motors, measurement-while-drilling (MWD) tools, and embedded high-frequency drilling dynamics recorders. Downhole and surface drilling dynamics data were used to fine- tune bit design and motor power section selection and continuously improve the durability of equipment, drilling efficiency, and footage drilled. Drilling optimization techniques used in oil and gas settings were successfully applied to this well, including analysis of data from drilling dynamics sensors embedded in the steerable motors and vertical drilling tools, surface surveillance of mechanical specific energy (MSE), and adopting a drilling parameter roadmap to improve drilling efficiency to minimize drilling dysfunctions and equipment damages. Through drilling optimization practices, the instrumented steerable motors with proper bit selections were able to drill more than 40 ft/hr on average, doubling the rate of penetration (ROP), footage, and run length experienced in previous granite wells. This paper presents a case study in which cutting-edge oil-and-gas drilling technologies were successfully applied to reduce the geothermal well drilling time by approximately half.


Sign in / Sign up

Export Citation Format

Share Document