Investigation on sheathing effect and failure modes of gypsum sheathed cold-formed steel wall panels subjected to bending

Structures ◽  
2019 ◽  
Vol 17 ◽  
pp. 87-101 ◽  
Author(s):  
Sivaganesh Selvaraj ◽  
Mahendrakumar Madhavan
2011 ◽  
Vol 201-203 ◽  
pp. 2900-2903 ◽  
Author(s):  
Chui Huon Tina Ting ◽  
Hieng Ho Lau

Built-up sections are used to resist load induced in a structure when a single section is not sufficient to carry the design load for example roof trusses. In current North American Specification, the provision has been substantially taken from research in hot-rolled built-up members connected with bolts or welds [1]. The aim of this paper is to investigate on built-up back-to-back channels stub columns experimentally and theoretically using Effective Width Method and Direct Strength Method. Compression test was performed on 5 lipped channel and 5 back-to-back channels stub columns fabricated from cold-formed steel sheets of 1.2mm thicknesses. The test results indicated that local buckling is the dominant failure modes of stub columns. Therefore, Effective Width Method predicts the capacity of stub columns compared to Direct Strength Method. When compared to the average test results, results based on EWM are 5% higher while results based on DSM are 12% higher for stub column.


Fire Research ◽  
2016 ◽  
Author(s):  
Hélder D. Craveiro ◽  
João Paulo C. Rodrigues ◽  
Luís M. Laím

Cold-formed steel (CFS) profiles with a wide range of cross-section shapes are commonly used in building construction industry. Nowadays several cross-sections can be built using the available standard single sections (C, U, Σ, etc.), namely open built-up and closed built-up cross-sections. This paper reports an extensive experimental investigation on the behavior of single and built-up cold-formed steel columns at both ambient and simulated fire conditions considering the effect of restraint to thermal elongation. The buckling behavior, ultimate loads and failure modes, of different types of CFS columns at both ambient and simulated fire conditions with restraint to thermal elongation, are presented and compared. Regarding the buckling tests at ambient temperature it was observed that the use of built-up cross-sections ensures significantly higher values of buckling loads. Especially for the built-up cross-sections the failure modes were characterized by the interaction of individual buckling modes, namely flexural about the minor axis, distortional and local buckling. Regarding the fire tests, it is clear that the same levels of restraint used in the experimental investigation induce different rates in the generated restraining forces due to thermal elongation of the columns. Another conclusion that can be drawn from the results is that by increasing the level of restraint to thermal elongation the failure of the columns is controlled by the generated restraining forces, whereas for lower levels of restraint the temperature plays a more important role. Hence, higher levels of imposed restraint to thermal elongation will lead to higher values of generated restraining forces and eventually to lower values of critical temperature and time.


Author(s):  
Bernardo A. Lejano

<p>Getting good lumber for housing construction is becoming difficult in the Philippines due to existing partial log ban. Although, the use of reinforced concrete is still the most popular in construction, an emerging alternative is the use of cold-formed steel (CFS). It is gaining popularity because of its high strength-to- weight ratio. However, information about the structural performance of locally-produced cold-formed steel is almost nonexistent. Although, design provisions are stipulated in the local Code, these are based on formulas developed abroad, hence the need to investigate these cold-formed steel. This study focuses on the C-section cold-formed steel, which is the most popularly used. The objective is to verify its performance when subjected to axial compression and flexure, both experimentally and computationally. For the computational part, the formulas stipulated in the National Structural Code of the Philippines were followed. For the experimental part, the cold-formed steel members were subjected to compression loads and flexural loads. Aside from usual sensors, high-speed cameras were used to capture the failure modes. For axial compression test, 80 specimens with different lengths and thicknesses were tested. For flexure, 24 specimens of back-to-back C-sections were subjected to 4-point bending test. Results showed the predicted strengths were well below the experimental values. In design, this means the use of Code-based formulas is conservative. Failure modes observed were torsional buckling and distortional buckling. Comparison of failure modes between experiment and computation shows 70% agreement for compression and 75% for flexure. Finite element method calculations were also done and were compared with experimental results.</p>


2020 ◽  
Vol 157 ◽  
pp. 107084 ◽  
Author(s):  
Nima Usefi ◽  
Hamid Ronagh ◽  
Pezhman Sharafi

Sign in / Sign up

Export Citation Format

Share Document