Highly sensitive carbon-based nanohybrid sensor platform for determination of 5-hydroxytryptamine receptor agonist (Eletriptan)

2019 ◽  
Vol 174 ◽  
pp. 206-213 ◽  
Author(s):  
S.I. Kaya ◽  
B. Demirkan ◽  
N.K. Bakirhan ◽  
E. Kuyuldar ◽  
S. Kurbanoglu ◽  
...  
2018 ◽  
Vol 21 (7) ◽  
pp. 462-467
Author(s):  
Babak Sadeghi

Aim and Objective: Ultrafine Ag/ZnO nanotetrapods (AZNTP) have been prepared successfully using silver (I)–bis (oxalato) zinc complex and 1, 3-diaminopropane (DAP) with a phase separation system, and have been injected into a diethyl/water solution. Materials and Methods: This crystal structure and lattice constant of the AZNTP obtained were investigated by means of a SEM, XRD, TEM and UV-vis spectrum. Results: The results of the present study demonstrated the growth and characterization AZNTP for humidity sensing and DAP plays a key role in the determination of particle morphology. AZNTP films with 23 nm in arm diameter have shown highly sensitive, quick response sensor material that works at room temperature.


2019 ◽  
Vol 15 (5) ◽  
pp. 505-510
Author(s):  
Yanjuan Zheng ◽  
Qiushi Peng ◽  
Rui Dong ◽  
Tingyu Chen ◽  
Yi Bao ◽  
...  

Introduction: A rapid, and accurate Ultra Performance Liquid Chromatography (UPLC) method was developed to simultaneously analyze Methocarbamol, Paracetamol and the related substances Materials and Methods: Waters ACQUITY UPLC® BEH Phenyl C18 column was used in conjunction with UV detection at 225nm. Gradient elution with 0.05M, pH 6 phosphate buffer and acetonitrile flow at 0.3mL /min rate were used to separate the substances. The retention times for 4-Aminopheno, Paracetamol, Guaifenesin, Methocarbamol, and 4-Chloroacetanilide were 1.319 minute, 2.224 minute, 4.467 minute, 4.769 minute and 5.433 minute respectively. The concentration was linear in the range of 2-100 µg/ml for Methocarbamol, and 1-100 µg/mL for Paracetamol. The percentage recoveries were between 99.28±1.23% to 100.57±0.99% for Methocarbamol, and between 99.08±1.23% to 101.23±1.39% for Paracetamol. Results and Discussion: The validated optimal protocol is robust and accurate for simultaneous analysis of Methocarbamol, Paracetamol and the related substances, applicable for bulk powder as well as pharmaceutical formulation. Conclusion: In this paper, a highly sensitive, accurate, and precise UPLC method with UV-Vis detection was developed and validated for quality control of MET and PAR in bulk as well as in pharmaceutical preparations.


Author(s):  
Lin He ◽  
Peixia Li ◽  
Kai Li ◽  
Tao Lin ◽  
Jin Luo ◽  
...  

A new cross double point discharge (CrossPD) microplasma was designed as an excitation source to construct a miniaturized optical emission spectrometer with hydride generation (HG) for sample introduction. The CrossPD...


Sign in / Sign up

Export Citation Format

Share Document