Influence of chloride ion concentration on the corrosion behavior of Al-bearing TRIP steels

2011 ◽  
Vol 130 (1-2) ◽  
pp. 743-749 ◽  
Author(s):  
F. El-Taib Heakal ◽  
N.S. Tantawy ◽  
O.S. Shehta
CORROSION ◽  
1969 ◽  
Vol 25 (4) ◽  
pp. 151-156 ◽  
Author(s):  
D. L. PIRON ◽  
E. P. KOUTSOUKOS ◽  
KEN NOBE

Abstract The corrosion behavior of nickel and Inconel in acidic solutions has been investigated by polarization methods. The cathodic Tafel slope for the h.e.r. of nickel in de-aerated 1N H2SO4 and the corresponding exchange current density were 135 mv and 3.4 μa/cm2. Two cathodic Tafel slopes and exchange currents for the h.e.r. were obtained for Inconel in the same solution: 50 mv and 0.22 /μa/cm2; 115 mv and 7.2 μa/cm2. With increase in concentration of chloride ions, the corrosion potential of nickel decreased and the open circuit differential capacitance increased. Each parameter approached a constant value at the higher chloride ion concentrations. Anodic polarization of both metals showed that the primary passivation potential, the critical and passive current densities increased with increase in chloride ion concentration. The passivity of Inconel was shown to be superior to that of nickel in acidic solutions in the absence and presence of chloride ions.


2016 ◽  
Vol 849 ◽  
pp. 121-127
Author(s):  
Ya Jie Chu ◽  
Xin Chen Han ◽  
Zong Hui Yang ◽  
Xiao Quan Li

The extruded AZ31B magnesium alloy plates of 4 mm thickness were butt welded using gas tungsten arc welding (GTA) process. The microstructure and corrosion behavior of the hot compressed welds were evaluated by conducting immersion test in NaCl solution at different immersion time and chloride ion concentrations. The specimens were exposed to immersion in order to characterize their corrosion rates. The corrosion morphology and pit morphology observation was carried out by scanning electron microscopy (SEM). The results showed that the corrosion rate of hot compressed magnesium alloy welds decreased with the increase in immersion time and the corrosion rate increased with the increase in chloride ion concentration, and the corrosion morphology was predominantly influenced by the distribution of β-phase.


2013 ◽  
Vol 643 ◽  
pp. 33-36
Author(s):  
Wei Ke An ◽  
An Hui Cai ◽  
Guo Jun Zhou ◽  
Yun Luo ◽  
Tie Lin Li ◽  
...  

The corrosion behavior of Cu50Zr40Ti10 (at. %) in HCl and NaCl solutions was investigated. The corrosion current densities icorr in HCl and NaCl solutions increase with increasing Clconcentration when the Cl- concentration is <0.5 molL-1, then continuously increase in the former and decrease in the latter. The icorr is larger in the latter than in the former when the Clconcentration is <0.5 molL-1, while inversely for in 1 molL-1 Cl- solution. The corrosion potential Ecorr decreases with increasing Cl- concentration in HCl. However, the change of the Ecorr vs. the chloride ion concentration in NaCl solution appears down-up-down.


2010 ◽  
Vol 95 ◽  
pp. 47-50 ◽  
Author(s):  
Guy Ben-Hamu ◽  
D. Eliezer ◽  
Kwang Seon Shin

The paper presented reveals the influence of chloride ion concentration on the corrosion and electrochemical behavior of new ZSMX wrought magnesium alloy in NaCl solution. The experimental techniques used include potentiodynamic polarization tests. The corrosion rate usually increased with the increase in chloride ion concentration. This result can be explained by the distribution of intermetalics.


Molecules ◽  
2019 ◽  
Vol 24 (21) ◽  
pp. 3970 ◽  
Author(s):  
Bruna T. L. Pereira ◽  
Mateus A. Gonçalves ◽  
Daiana T. Mancini ◽  
Kamil Kuca ◽  
Teodorico C. Ramalho

Platinum complexes have been studied for cancer treatment for several decades. Furthermore, another important platinum characteristic is related to its chemical shifts, in which some studies have shown that the 195Pt chemical shifts are very sensitive to the environment, coordination sphere, and oxidation state. Based on this relevant feature, Pt complexes can be proposed as potential probes for NMR spectroscopy, as the chemical shifts values will be different in different tissues (healthy and damaged) Therefore, in this paper, the main goal was to investigate the behavior of Pt chemical shifts in the different environments. Calculations were carried out in vacuum, implicit solvent, and inside the active site of P13K enzyme, which is related with breast cancer, using the density functional theory (DFT) method. Moreover, the investigation of platinum complexes with a selective moiety can contribute to early cancer diagnosis. Accordingly, the Pt complexes selected for this study presented a selective moiety, the 2-(4′aminophenyl)benzothiazole derivative. More specifically, two Pt complexes were used herein: One containing chlorine ligands and one containing water in place of chlorine. Some studies have shown that platinum complexes coordinated to chlorine atoms may suffer hydrolyses inside the cell due to the low chloride ion concentration. Thus, the same calculations were performed for both complexes. The results showed that both complexes presented different chemical shift values in the different proposed environments. Therefore, this paper shows that platinum complexes can be a potential probe in biological systems, and they should be studied not only for cancer treatment, but also for diagnosis.


2020 ◽  
Vol 10 (1) ◽  
Author(s):  
Adrian Radoń ◽  
Dariusz Łukowiec ◽  
Patryk Włodarczyk

AbstractThe dielectric properties and electrical conduction mechanism of bismuth oxychloride (BiOCl) plates synthesized using chloramine-T as the chloride ion source were investigated. Thermally-activated structure rebuilding was monitored using broadband dielectric spectroscopy, which showed that the onset temperature of this process was 283 K. This rebuilding was related to the introduction of free chloride ions into [Bi2O2]2+ layers and their growth, which increased the intensity of the (101) diffraction peak. The electrical conductivity and dielectric permittivity were related to the movement of chloride ions between plates (in the low-frequency region), the interplanar motion of Cl− ions at higher frequencies, vibrations of these ions, and charge carrier hopping at frequencies above 10 kHz. The influence of the free chloride ion concentration on the electrical conductivity was also described. Structure rebuilding was associated with a lower concentration of free chloride ions, which significantly decreased the conductivity. According to the analysis, the BiOCl plate conductivity was related to the movement of Cl− ions, not electrons.


Coatings ◽  
2021 ◽  
Vol 11 (7) ◽  
pp. 820
Author(s):  
Beibei Han ◽  
Mengyuan Yan ◽  
Dongying Ju ◽  
Maorong Chai ◽  
Susumu Sato

The amorphous hydrogenated (a-C:H) film-coated titanium, using different CH4/H2 and deposition times, was prepared by the ion beam deposition (IBD) method, which has the advantage of high adhesion because of the graded interface mixes at the atomic level. The chemical characterizations and corrosion behaviors of a-C:H film were investigated and evaluated by SEM, AFM, Raman spectroscopy, EPMA, TEM and XPS. An a-C:H film-coated titanium was corroded at 0.8 V, 90 °C in a 0.5 mol/L H2SO4 solution for 168 h. The metal ion concentration in the H2SO4 corrosion solution and the potentiodynamic polarization behavior were evaluated. Results indicate that a higher CH4/H2 of 1:0 and a deposition time of 12 h can result in a minimum ID/IG ratio of 0.827, Ra of 5.76 nm, metal ion concentration of 0.34 ppm in the corrosion solution and a corrosion current of 0.23 µA/cm2. The current density in this work meets the DOE’s 2020 target of 1 µA/cm2. Electrical conductivity is inversely proportional to the corrosion resistance. The significant improvement in the corrosion resistance of the a-C:H film was mainly attributed to the increased sp3 element and nanocrystalline TiC phase in the penetration layer. As a result, the a-C:H film-coated titanium at CH4/H2 = 1:0 with improved anti-corrosion behavior creates a great potential for PEMFC bipolar plates.


Sign in / Sign up

Export Citation Format

Share Document