Comparison study of membrane filtration direct count and an automated coliform and Escherichia coli detection system for on-site water quality testing

2009 ◽  
Vol 79 (1) ◽  
pp. 128-130 ◽  
Author(s):  
Marc Habash ◽  
Robert Johns
1982 ◽  
Vol 88 (2) ◽  
pp. 265-273 ◽  
Author(s):  
R. C. Wright

SummaryA selective membrane filtration medium is described for use in the rapid assessment of water quality in tropical countries where the incidence of faecal coliforms other than E. coli presents problems in the interpretation of results. The medium gives comparable results to MPN values obtained in the multiple tube dilution test using modified Gray's glutamate medium, and to membrane filtration counts obtained using M-FC broth and membrane-enriched Teepol broth, whilst differentiation of E. coli is enhanced.


2021 ◽  
Vol 15 ◽  
pp. 117863022110144
Author(s):  
Camille Zimmer ◽  
Alexandra Cassivi ◽  
Celia C Baía ◽  
Elizabeth Tilley ◽  
Robert Bain ◽  
...  

To monitor safely managed drinking water services, an increasing number of countries have integrated water quality testing for Escherichia coli into nationally-representative household surveys such as the Multiple Indicator Cluster Surveys (MICS). However, plastic waste generated during such water quality testing programs, mostly through the use of pre-sterilized disposable materials, is non-negligible. The objective of this study was to evaluate several re-use protocols for disposable filter funnels used by the MICS water quality test kits. Decontamination and re-use protocols were assessed in centralized laboratory and decentralized field settings and neither yielded positive results. Re-use of 100 mL sterile funnels decontaminated with an alcohol wipe resulted in a higher incidence of false positive results (i.e., positive contamination when processing sterile water), both in the laboratory and field; therefore, a higher proportion of positives tests can be expected if these components are re-used. Further improvements to the decontamination technique and training are needed before material re-use can be reliably adopted. Autoclaving the funnels for re-use is feasible, provided that there is capacity to re-package and distribute funnels in a sterile manner.


Author(s):  
Markus T Lasut ◽  
Adianse Tarigan

A study on water quality status of three riverine systems, S. Bailang (SB), S. Maasing (SM), and S. Tondano (ST), in coastal city of Manado, North Sulawesi Province, has been conducted to measure several water quality parameters, to analyse source and quality of wastewater discharge, and to assess the status of the rivers related to the water quality. Measurement of the parameters was conducted using three indicators, i.e. organic (BOD5) and in-organic (N-NO3 and P-PO4), and pathogenic microorganism (Escherichia coli [EC] and total coliform [TC]). The result showed that the level of water quality varied between the rivers. The average level of water quality (based on the observed parameters) in SB, respectively, was 0.317 mg/l, 0.093 mg/l, 2 mg/l, >2420 MPN, and  >2420 MPN; in SM, respectively, was 0.029 mg/l, 1.859 mg/l, 17.7 mg/l, >2420 MPN, and >2420 MPN; and in ST, respectively, was 0.299 mg/l, 0.252 mg/l, 3.5 mg/l, >2420 MPN, and >2420 MPN. The level of water quality between the rivers was not significantly different (p>0.05), except based on the parameter of N-NO3 which was significantly different (p<0.01). The status of the observed rivers varied based on the classes of their water utilities (according to the Government Regulation of Indonesia, No. 82, 2001); mostly was "unsuitable". Kajian tentang status kualitas air di 3 perairan sungai di kota pesisir Manado, S. Bailang (SB), S. Maasing (SM), dan S. Tondano (ST), Provinsi Sulawesi Utara, telah dilakukan yang bertujuan untuk mengukur beberapa parameter kualitas air, menganalisis sumber dan kualitas buangan limbah domestik, dan menilai status ketiga perairan sungai tersebut. Tiga indikator digunakan, yaitu: bahan organik (BOD5), bahan anorganik (N-NO3 dan P-PO4), dan mikroorganisme patogenik (Escherichia coli [EC] dan coliform total [TC]). Hasil kajian menunjukkan bahwa tingkat kualitas air perairan tersebut berbeda-beda. Konsentrasi rerata parameter kualitas air  (BOD5, N-NO3, P-PO4, EC, dan TC) di SB, berturut-turut, sebesar 0.317 mg/l, 0.093 mg/l, 2 mg/l, >2420 MPN, dan >2420 MPN; di SM, berturut-turut, sebesar 0.029 mg/l, 1.859 mg/l, 17.7 mg/l, >2420 MPN, dan >2420 MPN; dan di ST, berturut-turut, sebesar 0.299 mg/l, 0.252 mg/l, 3.5 mg/l, >2420 MPN, dan >2420 MPN. Konsentrasi kualitas air ketiga sungai tersebut tidak berbeda secara signifikan (p>0.05), kecuali parameter N-NO3 (p<0.01). Secara umum, kondisi kualitas air ketiga sungai tersebut, menurut Peraturan Pemerintah No. 82, 2001) berada dalam status “tidak cocok” untuk peruntukannya.


2010 ◽  
Vol 5 (4) ◽  
Author(s):  
J. L. Manuszak ◽  
M. MacPhee ◽  
S. Liskovich ◽  
L. Feldsher

The City of Baltimore, Maryland is one of many US cities faced with challenges related to increasing potable water demands, diminishing fresh water supplies, and aging infrastructure. To address these challenges, the City recently undertook a $7M study to evaluate water supply and treatment alternatives and develop the conceptual design for a new 120 million gallon per day (MGD) water treatment plant. As part of this study, an innovative raw water management tool was constructed to help model source water availability and predicted water quality based on integration of a new and more challenging surface water supply. A rigorous decision-making approach was then used to screen and select appropriate treatment processes. Short-listed treatment strategies were demonstrated through a year-long pilot study, and process design criteria were collected in order to assess capital and operational costs for the full-scale plant. Ultimately the City chose a treatment scheme that includes low-pressure membrane filtration and post-filter GAC adsorption, allowing for consistent finished water quality irrespective of which raw water supply is being used. The conceptual design includes several progressive concepts, which will: 1) alleviate treatment limitations at the City's existing plants by providing additional pre-clarification facilities at the new plant; and 2) take advantage of site conditions to design and operate the submerged membrane system by gravity-induced siphon, saving the City significant capital and operations and maintenance (O&M) costs. Once completed, the new Fullerton Water Filtration Plant (WFP) will be the largest low-pressure membrane plant in North America, and the largest gravity-siphon design in the world.