Rapid Construction of 4D High-Quality Microstructural Image for Cement Hydration Using Partial Information Registration

2021 ◽  
pp. 108471
Author(s):  
Liangliang Zhang ◽  
Lin Wang ◽  
Bo Yang ◽  
Sijie Niu ◽  
Yamin Han ◽  
...  
Agriculture ◽  
2021 ◽  
Vol 12 (1) ◽  
pp. 31
Author(s):  
Sicheng Zhang ◽  
Rui Zhao ◽  
Kening Wu ◽  
Qin Huang ◽  
Long Kang

To implement the balance system of cultivated land in occupation and supplement and to adhere to the principle of “supplement the occupied cultivated land of high quality with the one bearing same quality”, in the thesis, a field experiment was conducted to study the effects of woody peat on soil physical, chemical, and biological properties of the plough layer and its crop yield. Furthermore, the correlation between soil indexes and crop yield under the best fertilization mode through the addition of the natural material of woody peat instead of lengthy cultivation of the plough layer to rapidly construct a high-quality plough layer and solve the practical problem that the natural endowment of newly reclaimed cultivated land is far less than the occupied high-quality cultivated land was explored. The land remediation project of Fuping County, Hebei Province, was taken as the experimental area, and the five most representative and effective datasets were selected and studied. The results demonstrated that the addition of woody peat and rotten straw could reduce soil particle size and bulk density and alleviate soil viscosity and acidification. An increase in soil organic matter, soil microbial biomass carbon (MBC), alkali-hydrolyzable nitrogen, available phosphorus, and available potassium and a decrease in the heavy metal content were also observed. The results indicated that the application of woody peat achieved the expected effect of the rapid construction of a high-quality plough layer. The best mode of fertilization was A2, which provided a good reference for the rapid construction of a high-quality plough layer in the future. The analysis of the correlation between soil indexes and crop yield illustrated that the organic matter content, soil available nutrients, and crop yield had a significant positive correlation; the organic matter content and soil available nutrients showed the same tendency, which suggests that soil organic matter content and soil fertility level are closely related and that soil fertility plays a decisive role in crop yield under the same external conditions. Woody peat exerted an eminent influence on the organic matter content and soil available nutrients to determine the change in crop yield, which provides a reliable basis for future research on land improvement projects to increase crop yield.


2014 ◽  
Vol 553 ◽  
pp. 818-823
Author(s):  
Che Cheng Chang ◽  
Qing Li

While smooth isosurface and the subsequent body mesh construction is a well-developed modeling technique and widely used in medical imaging and engineering modeling, it is rarely performed in transient analysis and other iterative procedures due to relatively high computational cost. Voxelized modeling is often used as an alternative for simplicity at a cost of numerical accuracy. To overcome this problem, an isosurface modeling technique is developed in this paper to enable its seamless integration into iterative processes. This approach involves a rapid construction of closed isosurfaces using the Marching Cubes methods and a selective clean-up operation to smooth the surface mesh. This technique generates high quality isosurface meshes with clearly defined 3D domains and boundaries, which in turn provide a suitable foundation for the finite element analysis of two-phase problems. Its robustness, flexibility and suitability for applications in medical imaging and topology optimization are also demonstrated in this paper.


1966 ◽  
Vol 24 ◽  
pp. 51-52
Author(s):  
E. K. Kharadze ◽  
R. A. Bartaya

The unique 70-cm meniscus-type telescope of the Abastumani Astrophysical Observatory supplied with two objective prisms and the seeing conditions characteristic at Mount Kanobili (Abastumani) permit us to obtain stellar spectra of a high quality. No additional design to improve the “climate” immediately around the telescope itself is being applied. The dispersions and photographic magnitude limits are 160 and 660Å/mm, and 12–13, respectively. The short-wave end of spectra reaches 3500–3400Å.


Author(s):  
R. L. Lyles ◽  
S. J. Rothman ◽  
W. Jäger

Standard techniques of electropolishing silver and silver alloys for electron microscopy in most instances have relied on various CN recipes. These methods have been characteristically unsatisfactory due to difficulties in obtaining large electron transparent areas, reproducible results, adequate solution lifetimes, and contamination free sample surfaces. In addition, there are the inherent health hazards associated with the use of CN solutions. Various attempts to develop noncyanic methods of electropolishing specimens for electron microscopy have not been successful in that the specimen quality problems encountered with the CN solutions have also existed in the previously proposed non-cyanic methods.The technique we describe allows us to jet polish high quality silver and silver alloy microscope specimens with consistant reproducibility and without the use of CN salts.The solution is similar to that suggested by Myschoyaev et al. It consists, in order of mixing, 115ml glacial actic acid (CH3CO2H, specific wt 1.04 g/ml), 43ml sulphuric acid (H2SO4, specific wt. g/ml), 350 ml anhydrous methyl alcohol, and 77 g thiourea (NH2CSNH2).


Author(s):  
A. V. Crewe ◽  
J. Wall ◽  
L. M. Welter

A scanning microscope using a field emission source has been described elsewhere. This microscope has now been improved by replacing the single magnetic lens with a high quality lens of the type described by Ruska. This lens has a focal length of 1 mm and a spherical aberration coefficient of 0.5 mm. The final spot size, and therefore the microscope resolution, is limited by the aberration of this lens to about 6 Å.The lens has been constructed very carefully, maintaining a tolerance of + 1 μ on all critical surfaces. The gun is prealigned on the lens to form a compact unit. The only mechanical adjustments are those which control the specimen and the tip positions. The microscope can be used in two modes. With the lens off and the gun focused on the specimen, the resolution is 250 Å over an undistorted field of view of 2 mm. With the lens on,the resolution is 20 Å or better over a field of view of 40 microns. The magnification can be accurately varied by attenuating the raster current.


Author(s):  
L. Mulestagno ◽  
J.C. Holzer ◽  
P. Fraundorf

Due to the wealth of information, both analytical and structural that can be obtained from it TEM always has been a favorite tool for the analysis of process-induced defects in semiconductor wafers. The only major disadvantage has always been, that the volume under study in the TEM is relatively small, making it difficult to locate low density defects, and sample preparation is a somewhat lengthy procedure. This problem has been somewhat alleviated by the availability of efficient low angle milling.Using a PIPS® variable angle ion -mill, manufactured by Gatan, we have been consistently obtaining planar specimens with a high quality thin area in excess of 5 × 104 μm2 in about half an hour (milling time), which has made it possible to locate defects at lower densities, or, for defects of relatively high density, obtain information which is statistically more significant (table 1).


Author(s):  
C. O. Jung ◽  
S. J. Krause ◽  
S.R. Wilson

Silicon-on-insulator (SOI) structures have excellent potential for future use in radiation hardened and high speed integrated circuits. For device fabrication in SOI material a high quality superficial Si layer above a buried oxide layer is required. Recently, Celler et al. reported that post-implantation annealing of oxygen implanted SOI at very high temperatures would eliminate virtually all defects and precipiates in the superficial Si layer. In this work we are reporting on the effect of three different post implantation annealing cycles on the structure of oxygen implanted SOI samples which were implanted under the same conditions.


Author(s):  
Judith M. Brock ◽  
Max T. Otten ◽  
Marc. J.C. de Jong

A Field Emission Gun (FEG) on a TEM/STEM instrument provides a major improvement in performance relative to one equipped with a LaB6 emitter. The improvement is particularly notable for small-probe techniques: EDX and EELS microanalysis, convergent beam diffraction and scanning. The high brightness of the FEG (108 to 109 A/cm2srad), compared with that of LaB6 (∼106), makes it possible to achieve high probe currents (∼1 nA) in probes of about 1 nm, whilst the currents for similar probes with LaB6 are about 100 to 500x lower. Accordingly the small, high-intensity FEG probes make it possible, e.g., to analyse precipitates and monolayer amounts of segregation on grain boundaries in metals or ceramics (Fig. 1); obtain high-quality convergent beam patterns from heavily dislocated materials; reliably detect 1 nm immuno-gold labels in biological specimens; and perform EDX mapping at nm-scale resolution even in difficult specimens like biological tissue.The high brightness and small energy spread of the FEG also bring an advantage in high-resolution imaging by significantly improving both spatial and temporal coherence.


Author(s):  
Yoshichika Bando ◽  
Takahito Terashima ◽  
Kenji Iijima ◽  
Kazunuki Yamamoto ◽  
Kazuto Hirata ◽  
...  

The high quality thin films of high-Tc superconducting oxide are necessary for elucidating the superconducting mechanism and for device application. The recent trend in the preparation of high-Tc films has been toward “in-situ” growth of the superconducting phase at relatively low temperatures. The purpose of “in-situ” growth is to attain surface smoothness suitable for fabricating film devices but also to obtain high quality film. We present the investigation on the initial growth manner of YBCO by in-situ reflective high energy electron diffraction (RHEED) technique and on the structural and superconducting properties of the resulting ultrathin films below 100Å. The epitaxial films have been grown on (100) plane of MgO and SrTiO, heated below 650°C by activated reactive evaporation. The in-situ RHEED observation and the intensity measurement was carried out during deposition of YBCO on the substrate at 650°C. The deposition rate was 0.8Å/s. Fig. 1 shows the RHEED patterns at every stage of deposition of YBCO on MgO(100). All the patterns exhibit the sharp streaks, indicating that the film surface is atomically smooth and the growth manner is layer-by-layer.


Sign in / Sign up

Export Citation Format

Share Document