A fast-response pressure sensor based on a dye-adsorbed silica nanoparticle film

2012 ◽  
Vol 171-172 ◽  
pp. 343-349 ◽  
Author(s):  
Masaharu Kameda ◽  
Hitoshi Seki ◽  
Taro Makoshi ◽  
Yutaka Amao ◽  
Kazuyuki Nakakita
Sensors ◽  
2020 ◽  
Vol 20 (14) ◽  
pp. 3858
Author(s):  
Shinya Kano ◽  
Harutaka Mekaru

Fast-response humidity sensors using nanomaterials are attractive and have been intensively studied. Among the various nanomaterials, nonporous inorganic nanoparticles are suitable for use in humidity sensitive films for sensors. Here, we focus on a nonporous inorganic nanoparticle film and investigate a humidity sensor using the film. Hysteresis error and a dynamic response to a change of humidity are fundamental specifications of humidity sensors. A humidity sensor using a 50 nm silica nanoparticle film shows a hysteresis error of 2% at 85% RH and a response/recovery time of 2.8/2.3 s in 30% RH to 70% RH. We also summarize response/recovery times and hysteresis errors of state-of-the-art humidity sensors. As compared to those of commercial sensors and porous nanoparticle-based sensors evaluated using saturated salt solutions, the fabricated sensor shows a comparative hysteresis error and shorter response time.


2020 ◽  
Vol 12 (1) ◽  
Author(s):  
Jung Joon Lee ◽  
Srinivas Gandla ◽  
Byeongjae Lim ◽  
Sunju Kang ◽  
Sunyoung Kim ◽  
...  

Abstract Conformal and ultrathin coating of highly conductive PEDOT:PSS on hydrophobic uneven surfaces is essential for resistive-based pressure sensor applications. For this purpose, a water-based poly(3,4-ethylenedioxythiophene) polystyrene sulfonate (PEDOT:PSS) solution was successfully exchanged to an organic solvent-based PEDOT:PSS solution without any aggregation or reduction in conductivity using the ultrafiltration method. Among various solvents, the ethanol (EtOH) solvent-exchanged PEDOT:PSS solution exhibited a contact angle of 34.67°, which is much lower than the value of 96.94° for the water-based PEDOT:PSS solution. The optimized EtOH-based PEDOT:PSS solution exhibited conformal and uniform coating, with ultrathin nanocoated films obtained on a hydrophobic pyramid polydimethylsiloxane (PDMS) surface. The fabricated pressure sensor showed high performances, such as high sensitivity (−21 kPa−1 in the low pressure regime up to 100 Pa), mechanical stability (over 10,000 cycles without any failure or cracks) and a fast response time (90 ms). Finally, the proposed pressure sensor was successfully demonstrated as a human blood pulse rate sensor and a spatial pressure sensor array for practical applications. The solvent exchange process using ultrafiltration for these applications can be utilized as a universal technique for improving the coating property (wettability) of conducting polymers as well as various other materials.


2002 ◽  
Vol 124 (3) ◽  
pp. 784-790 ◽  
Author(s):  
Jorge L. Parrondo-Gayo ◽  
Jose´ Gonza´lez-Pe´rez ◽  
Joaquı´n Ferna´ndez-Francos

An experimental investigation is presented which analyzes the unsteady pressure distribution existing in the volute of a conventional centrifugal pump with a nondimensional specific speed of 0.48, for flow-rates from 0% to 160% of the best-efficiency point. For that purpose, pressure signals were obtained at 36 different locations along the volute casing by means of fast-response pressure transducers. Particular attention was paid to the pressure fluctuations at the blade passage frequency, regarding both amplitude and phase delay relative to the motion of the blades. Also, the experimental data obtained was used to adjust the parameters of a simple acoustic model for the volute of the pump. The results clearly show the leading role played by the tongue in the impeller-volute interaction and the strong increase in the magnitude of dynamic forces and dipole-like sound generation in off-design conditions.


2005 ◽  
Vol 6 (1) ◽  
pp. 85-93 ◽  
Author(s):  
H Nakamura ◽  
I Asano ◽  
M Adachi ◽  
J Senda

The Pitot tube flowmetering technique has been used to measure pulsating flow from a vehicle engine exhaust. In general, flowmetering techniques that utilize differential pressure measurements based on Bernoulli's theory are likely to show erroneous readings when measuring an average flowrate of pulsating flow. The primary reason for this is the non-linear relationship between the differential pressure and the flowrate; i.e. the flowrate is proportional to the square root of the differential pressure. Therefore, an average of the differential pressure does not give an average of pulsating flow. In this study, fast response pressure transducers have been used to measure the pulsating pressure. Then the pulsating differential pressure is converted to the flowrate while keeping the pulsation unaveraged. An average flowrate is then calculated in the flowrate domain in order to maintain linearity before and after averaging. The peak amplitude of a pulsation measured here was about 1800 L/min at an average flowrate of 70 L/min when the engine ran at idle speed. This measurement has been confirmed by measuring the pulsation with a gas analyser. The results show a large amount of back and forth gas movement in the exhaust tube. This magnitude of pulsation can cause as much as five times higher erroneous results with the pressure domain averaging when compared to a flowrate domain averaging.


Author(s):  
Toshinori Watanabe ◽  
Toshihiko Azuma ◽  
Seiji Uzawa ◽  
Takehiro Himeno ◽  
Chihiro Inoue

A fast-response pressure-sensitive paint (PSP) technique was applied to the measurement of unsteady surface pressure of an oscillating cascade blade in a transonic flow. A linear cascade was used, and its central blade was oscillated in a translational manner. The unsteady pressure distributions of the oscillating blade and two stationary neighbors were measured using the fast-response PSP technique, and the unsteady aerodynamic force on the blade was obtained by integrating the data obtained on the pressures. The measurements made with the PSP technique were compared with those obtained by conventional methods for the purpose of validation. From the results, the PSP technique was revealed to be capable of measuring the unsteady surface pressure, which is used for flutter analysis in transonic conditions.


Author(s):  
O. Schennach ◽  
R. Pecnik ◽  
B. Paradiso ◽  
E. Go¨ttlich ◽  
A. Marn ◽  
...  

The current paper presents the results of numerical and experimental clocking investigations performed in a high-pressure transonic turbine with a downstream vane row. The objective was a detailed analysis of shock and wake interactions in such a 1.5 stage machine while clocking the vanes. Therefore a transient 3D-Navier Stokes calculation was done for two clocking positions and the three dimensional results are compared with Laser-Doppler-Velocimetry measurements at midspan. Additionally the second vane was equipped with fast response pressure transducers to record the instantaneous surface pressure for 20 different clocking positions at midspan.


AIAA Journal ◽  
2014 ◽  
Vol 52 (11) ◽  
pp. 2462-2470 ◽  
Author(s):  
W. Flaherty ◽  
Todd M. Reedy ◽  
Gregory S. Elliott ◽  
J. M. Austin ◽  
Ryan F. Schmit ◽  
...  

Author(s):  
R. Dambach ◽  
H. P. Hodson

The use of multi-sensor fast-response pressure probes is now relatively common place. Unfortunately, these probes are often larger than ideal. It is for this reason that single sensor probes are sometimes used in investigations of unsteady flow. In use, the single sensor probe must be placed at a number of different orientations to the flow, often achieved by simply rotating the stem of the probe mount. The run time of a given experiment increases in proportion to the number of orientations employed. Furthermore, the number of orientations is usually more than is strictly required due to poor conditioning of the experiment. This results in a significant amount of redundant information being available and run-time costs being increased. This paper describes a data reduction technique that reduces the run time cost of using single sensor fast response probes to the minimum. This is achieved by using all of the data obtained in the experiment so that there is no redundancy no matter how many orientations are employed. The method relies on comparing the measured data with the calibration data in order to obtain a best fit between the two datasets.


Author(s):  
Mehmet Mersinligil ◽  
Jean-Franc¸ois Brouckaert ◽  
Julien Desset

This paper presents the first experimental engine and test rig results obtained from a fast response cooled total pressure probe. The first objective of the probe design was to favor continuous immersion of the probe into the engine to obtain time series of pressure with a high bandwidth and therefore statistically representative average fluctuations at the blade passing frequency. The probe is water cooled by a high pressure cooling system and uses a conventional piezo-resistive pressure sensor which yields therefore both time-averaged and time-resolved pressures. The initial design target was to gain the capability of performing measurements at the temperature conditions typically found at high pressure turbine exit (1100–1400K) with a bandwidth of at least 40kHz and in the long term at combustor exit (2000K or higher). The probe was first traversed at the turbine exit of a Rolls-Royce Viper turbojet engine, at exhaust temperatures around 750 °C and absolute pressure of 2.1bars. The probe was able to resolve the high blade passing frequency (≈23kHz) and several harmonics up to 100kHz. Besides the average total pressure distributions from the radial traverses, phase-locked averages and random unsteadiness are presented. The probe was also used in a virtual three-hole mode yielding unsteady yaw angle, static pressure and Mach number. The same probe was used for measurements in a Rolls-Royce intermediate pressure burner rig. Traverses were performed inside the flame tube of a kerosene burner at temperatures above 1600 °C. The probe successfully measured the total pressure distribution in the flame tube and typical frequencies of combustion instabilities were identified during rumble conditions. The cooling performance of the probe is compared to estimations at the design stage and found to be in good agreement. The frequency response of the probe is compared to cold shock tube results and a significant increase in the natural frequency of the line-cavity system formed by the conduction cooled screen in front of the miniature pressure sensor were observed.