Seismic response of clay-pile-raft-superstructure systems subjected to far-field ground motions

2017 ◽  
Vol 101 ◽  
pp. 209-224 ◽  
Author(s):  
Lei Zhang ◽  
Huabei Liu
2020 ◽  
Vol 36 (3) ◽  
pp. 1485-1516
Author(s):  
Jui-Liang Lin ◽  
Wen-Hui Chen ◽  
Fu-Pei Hsiao ◽  
Yuan-Tao Weng ◽  
Wen-Cheng Shen ◽  
...  

A shaking table test of a three-story reinforced concrete (RC) building was conducted. The tested building is vertically irregular because of the first story’s elevated height and the third story’s added RC walls. In addition to far-field ground motions, near-fault ground motions were exerted on this building. A numerical model of the three-story building was constructed. Comparing with the test results indicates that the numerical model is satisfactory for simulating the seismic response of the three-story building. This validated numerical model was then further applied to look into two issues: the effective section rigidities of RC members and the effects of near-fault ground motions. The study results show the magnitude of the possible discrepancy between the actual seismic response and the estimated seismic response, when the effective section rigidities of the RC members are treated as in common practice. An incremental dynamic analysis of the three-story RC building subjected to one far-field and one near-fault ground motion, denoted as CHY047 and TCU052, respectively, was conducted. In comparison with the far-field ground motion, the near-fault ground motion is more destructive to this building. In addition, the effect of the selected near-fault ground motion (i.e. TCU052) on the building’s collapse is clearly identified.


2014 ◽  
Vol 2014 ◽  
pp. 1-11 ◽  
Author(s):  
Dora Foti

Several steel moment-resisting framed buildings were seriously damaged during Northridge (1994); Kobe (1995); Kocaeli, Turkey (1999), earthquakes. Indeed, for all these cases, the earthquake source was located under the urban area and most victims were in near-field areas. In fact near-field ground motions show velocity and displacement peaks higher than far-field ones. Therefore, the importance of considering near-field ground motion effects in the seismic design of structures is clear. This study analyzes the seismic response of five-story steel moment-resisting frames subjected to Loma Prieta (1989) earthquake—Gilroy (far-field) register and Santa Cruz (near-field) register. The design of the frames verifies all the resistance and stability Eurocodes’ requirements and the first mode has been determined from previous shaking-table tests. In the frames two diagonal braces are installed in different positions. Therefore, ten cases with different periods are considered. Also, friction dampers are installed in substitution of the braces. The behaviour of the braced models under the far-field and the near-field records is analysed. The responses of the aforementioned frames equipped with friction dampers and subjected to the same ground motions are discussed. The maximum response of the examined model structures with and without passive dampers is analysed in terms of damage indices, acceleration amplification, base shear, and interstory drifts.


2021 ◽  
Vol 11 (4) ◽  
pp. 1740
Author(s):  
Van Bac Nguyen ◽  
Jungwon Huh ◽  
Bismark Kofi Meisuh ◽  
Jongwoo Kim ◽  
Inn-Joon Park

In this study, the seismic response of a container crane under near-field and far-field ground motions was investigated using a shaking table test on a 1/20 scale crane. The 1/20 scale crane was designed and fabricated based on the similitude laws, in which three independent quantities: geometric length, acceleration, and elastic modulus, were used to design the 1/20 scale crane. A series of shaking table tests were conducted at the Seismic Research and Test Center, Pusan National University, Yangsan Campus to evaluate the seismic response of the scale crane under near-field and far-field ground motions. The results show that the near-field ground motions can cause larger internal forces (that is, axial force and two bending moments) in the landside and seaside legs and larger portal drift than the far-field ground motions. The portal drift of the container crane subjected to the near-field ground motions was 43% higher than that of the container crane subjected to the far-field ground motions. Furthermore, when subjected to the near-field ground motion, the bending moment in the crane’s portal leg was 37% higher than the bending moment when the crane was subjected to the far-field ground motions.


2006 ◽  
Vol 22 (2) ◽  
pp. 367-390 ◽  
Author(s):  
Erol Kalkan ◽  
Sashi K. Kunnath

This paper investigates the consequences of well-known characteristics of near-fault ground motions on the seismic response of steel moment frames. Additionally, idealized pulses are utilized in a separate study to gain further insight into the effects of high-amplitude pulses on structural demands. Simple input pulses were also synthesized to simulate artificial fling-step effects in ground motions originally having forward directivity. Findings from the study reveal that median maximum demands and the dispersion in the peak values were higher for near-fault records than far-fault motions. The arrival of the velocity pulse in a near-fault record causes the structure to dissipate considerable input energy in relatively few plastic cycles, whereas cumulative effects from increased cyclic demands are more pronounced in far-fault records. For pulse-type input, the maximum demand is a function of the ratio of the pulse period to the fundamental period of the structure. Records with fling effects were found to excite systems primarily in their fundamental mode while waveforms with forward directivity in the absence of fling caused higher modes to be activated. It is concluded that the acceleration and velocity spectra, when examined collectively, can be utilized to reasonably assess the damage potential of near-fault records.