Effect evaluation of micro/nano structured materials on the performance of solar thermophotovoltaic system: An analysis based on measurement data

Solar Energy ◽  
2022 ◽  
Vol 231 ◽  
pp. 1037-1047
Author(s):  
Shiquan Shan ◽  
Qi Zhang ◽  
Binghong Chen ◽  
Gan He ◽  
Siqi Jia ◽  
...  
2019 ◽  
pp. 52-56
Author(s):  
Yu.F. Glukhov ◽  
N.V. Krutikov ◽  
A.V. Ivanov ◽  
N.P. Muravskaya

We have studied and analyzed status and metrological supervision of blood glucose monitors, individual devices for a person’s blood glucose level measurement. It has been indicated that nowadays blood glucose monitors like other individual devices for medical measurement are not allowed to be involved in telemedicine public service. This accounts for absence of metrological supervision with these measurement devices in telemedicine. In addition, the key problem is absence of safe methods and means of remote verificaition, calibration and transmission of measurement data to health care centers. The article offers a remote test method for blood glucose monitors using a number of resistors with values correlating with measured blood glucose level. The available method has been successfully trialed in real practice.


2014 ◽  
Vol 5 (2) ◽  
pp. 157-166 ◽  
Author(s):  
Cs. Szász

The paper presents an intelligent building (IB) development strategy emphasizing the locally available non-polluting renewable energy resources utilization. Considering the immense complexity of the topic, the implementation strategy of the main energy-flow processes is unfolded, using the net zero-energy building concept (NZEB). Noticeably, in the first research steps the mathematical background of the considered NZEB strategy has been developed and presented. Then careful LabView software-based simulations prove that the adopted strategy is feasible for implementation. The result of the above mentioned research efforts is a set of powerful and versatile software toolkits well suitable to model and simulate complex heating, ventilation and air-conditioning processes and to perform energy balance performance evaluations. Besides the elaborated mathematical models, concrete software implementation examples and measurement data also is provided in the paper. Finally, the proposed original models offer a feasible solution for future developments and research in NZEB applications modelling and simulation purposes.


2005 ◽  
Vol 33 (1) ◽  
pp. 38-62 ◽  
Author(s):  
S. Oida ◽  
E. Seta ◽  
H. Heguri ◽  
K. Kato

Abstract Vehicles, such as an agricultural tractor, construction vehicle, mobile machinery, and 4-wheel drive vehicle, are often operated on unpaved ground. In many cases, the ground is deformable; therefore, the deformation should be taken into consideration in order to assess the off-the-road performance of a tire. Recent progress in computational mechanics enabled us to simulate the large scale coupling problem, in which the deformation of tire structure and of surrounding medium can be interactively considered. Using this technology, hydroplaning phenomena and tire traction on snow have been predicted. In this paper, the simulation methodology of tire/soil coupling problems is developed for pneumatic tires of arbitrary tread patterns. The Finite Element Method (FEM) and the Finite Volume Method (FVM) are used for structural and for soil-flow analysis, respectively. The soil is modeled as an elastoplastic material with a specified yield criterion and a nonlinear elasticity. The material constants are referred to measurement data, so that the cone penetration resistance and the shear resistance are represented. Finally, the traction force of the tire in a cultivated field is predicted, and a good correlation with experiments is obtained.


Author(s):  
Gary Goertz ◽  
James Mahoney

Some in the social sciences argue that the same logic applies to both qualitative and quantitative research methods. This book demonstrates that these two paradigms constitute different cultures, each internally coherent yet marked by contrasting norms, practices, and toolkits. The book identifies and discusses major differences between these two traditions that touch nearly every aspect of social science research, including design, goals, causal effects and models, concepts and measurement, data analysis, and case selection. Although focused on the differences between qualitative and quantitative research, the book also seeks to promote toleration, exchange, and learning by enabling scholars to think beyond their own culture and see an alternative scientific worldview. The book is written in an easily accessible style and features a host of real-world examples to illustrate methodological points.


2014 ◽  
Vol 6 (1) ◽  
pp. 1006-1015
Author(s):  
Negin Shagholi ◽  
Hassan Ali ◽  
Mahdi Sadeghi ◽  
Arjang Shahvar ◽  
Hoda Darestani ◽  
...  

Medical linear accelerators, besides the clinically high energy electron and photon beams, produce other secondary particles such as neutrons which escalate the delivered dose. In this study the neutron dose at 10 and 18MV Elekta linac was obtained by using TLD600 and TLD700 as well as Monte Carlo simulation. For neutron dose assessment in 2020 cm2 field, TLDs were calibrated at first. Gamma calibration was performed with 10 and 18 MV linac and neutron calibration was done with 241Am-Be neutron source. For simulation, MCNPX code was used then calculated neutron dose equivalent was compared with measurement data. Neutron dose equivalent at 18 MV was measured by using TLDs on the phantom surface and depths of 1, 2, 3.3, 4, 5 and 6 cm. Neutron dose at depths of less than 3.3cm was zero and maximized at the depth of 4 cm (44.39 mSvGy-1), whereas calculation resulted  in the maximum of 2.32 mSvGy-1 at the same depth. Neutron dose at 10 MV was measured by using TLDs on the phantom surface and depths of 1, 2, 2.5, 3.3, 4 and 5 cm. No photoneutron dose was observed at depths of less than 3.3cm and the maximum was at 4cm equal to 5.44mSvGy-1, however, the calculated data showed the maximum of 0.077mSvGy-1 at the same depth. The comparison between measured photo neutron dose and calculated data along the beam axis in different depths, shows that the measurement data were much more than the calculated data, so it seems that TLD600 and TLD700 pairs are not suitable dosimeters for neutron dosimetry in linac central axis due to high photon flux, whereas MCNPX Monte Carlo techniques still remain a valuable tool for photonuclear dose studies.


Sign in / Sign up

Export Citation Format

Share Document