P3. Abstract Title: A Point-of-Care Assay for Measuring Thrombin Activity in Finger-Prick Whole Blood

2019 ◽  
Vol 182 ◽  
pp. 4-5 ◽  
Author(s):  
Y. Dai ◽  
P. Gross
Author(s):  
Gary Brook ◽  
Tetiana Stepchenkova ◽  
Innocent M. Ali ◽  
Sandra Chipuka ◽  
Neha Goel ◽  
...  

Remote areas of many low and middle income (LMI) countries have poor access to HIV viral load (HIV VL) testing. The SAMBA-II (Simple Amplification-based Assay) Semi-Q Whole Blood Test (Diagnostics for the Real World (DRW), Cambridge, UK) is a point of care assay which uses leucodepletion technology to allow whole blood testing in remote settings. 1540 consecutive HIV-positive clinic patients in Cameroon (250), UK (633), Ukraine (412) and Zimbabwe (245) donated venous blood (all countries) and finger-prick blood (all except UK) for testing on SAMBA-II. SAMBA II results were compared with simultaneous plasma results on the Abbott RealTime HIV-1 (Abbott Molecular, Des Plaines, IL) viral load assay and interpreted as either <1000 RNA copies/ml or ≥1000 RNA copies/ml. For 1528 venous whole-blood samples tested on SAMBA II, overall percent agreement with the reference test at a cut-off of HIV VL ≥1000 cps/ml was 96.9% (1480/1528 95% CI 95.9-97.7), negative percent agreement 97.7% (1259/1289 95% CI 96.7-98.4), positive percent agreement 92.5% (221/239 95% CI 88.4-95.5). For 854 finger-prick samples there was 95.0% (811/854 95% CI 93.3-96.3) overall percent agreement; negative percent agreement 98.0% (625/638, 95% CI 96.5-98.9); positive percent agreement 86.1% (186/216 95% CI 80.8-90.4). These rose to 93.5% (82.1, 98.6), 97.6% (95.6, 98.8) and 95.6% (93.3, 97.3) after exclusion of aberrant results from the Ukraine centre. These results show a high level of agreement between SAMBA-II and a laboratory-based assay. SAMBA-II has a performance that is suitable to use as a VL point of care assay in remote settings


2003 ◽  
Vol 332 (1-2) ◽  
pp. 51-59 ◽  
Author(s):  
Jae Soon Ahn ◽  
Sunga Choi ◽  
Sang Ho Jang ◽  
Hyuk Jae Chang ◽  
Jae Hoon Kim ◽  
...  

2012 ◽  
pp. n/a-n/a ◽  
Author(s):  
Jens Raila ◽  
Francis Enjalbert ◽  
Ralf Mothes ◽  
Andrea Hurtienne ◽  
Florian J. Schweigert

Author(s):  
Mario A. Inchiosa ◽  
Suryanarayana Pothula ◽  
Keshar Kubal ◽  
Vajubhai T. Sanchala ◽  
Iris Navarro

2011 ◽  
Vol 32 (1) ◽  
pp. 47-53 ◽  
Author(s):  
Mario A. Inchiosa ◽  
Suryanarayana Pothula ◽  
Keshar Kubal ◽  
Vajubhai T. Sanchala ◽  
Iris Navarro

2017 ◽  
Vol 7 (1) ◽  
Author(s):  
Sarah Fidler ◽  
Heather Lewis ◽  
Jodi Meyerowitz ◽  
Kristin Kuldanek ◽  
John Thornhill ◽  
...  

2017 ◽  
Vol 2 (7) ◽  
pp. 514-520 ◽  
Author(s):  
Jason Grebely ◽  
Francois M J Lamoury ◽  
Behzad Hajarizadeh ◽  
Yasmin Mowat ◽  
Alison D Marshall ◽  
...  

2020 ◽  
Vol 41 (Supplement_2) ◽  
Author(s):  
R Kanji ◽  
Y.X Gue ◽  
D Dinarvand ◽  
M.Q Farag ◽  
D.A Gorog

Abstract Introduction Patients with diabetes mellitus (DM) are increased risk of myocardial infarction (MI) and following a MI, patients with DM have an increased risk of recurrent MI and cardiovascular (CV) death. Plasma turbidimetry studies show that hypofibrinolysis is a key abnormality in DM that may drive increased ischaemic risk. Such assays are cumbersome, require specialist expertise and do not provide information in a clinically-relevant timeframe. Assessment of fibrinolysis in whole blood, using a point-of-care assay, has revealed that in ACS patients, impaired fibrinolysis is predictive of adverse CV events. Whether this technique can identify residual risk in patients with DM, is unclear. Purpose It was our aim to compare thrombotic and endogenous fibrinolytic status between patients with and without DM, presenting with ACS. Methods We conducted a prospective, observational study of consecutive patients admitted with ACS. Venous blood was taken to assess thrombotic and thrombolytic status using the point-of-care Global Thrombosis Test, assessing time to occlusive thrombus formation under high shear (occlusion time, OT) and time taken for spontaneous lysis of the thrombus (lysis yime, LT). Blood was taken after dual antiplatelet therapy (DAPT) loading, but before administration of fondaparinux or low molecular weight heparin. Patients with renal or hepatic impairment, known bleeding diathesis, thrombocytopenia and those taking anticoagulation were excluded. Results A total of 775 patients were included, of whom 158 (20%) had DM. Patients with DM, compared to those without DM, more frequently had hypertension (70% vs. 39%, p&lt;0.001), hyperlipidaemia (65% vs. 29%, p&lt;0.001), higher BMI (28.6 [25.3–32.0] vs. 26.6 [23.7–29.8] kg/m2, p&lt;0.001) and prior MI (28% vs 9%, p&lt;0.001), but were less often smokers (23% vs. 34% p=0.007). In all other clinical characteristics DM and non-DM patients were matched. Time to occlusive thrombus formation was similar in patients with and without DM (OT 401 (284–519) s vs. 391 (289–514) s, p=0.603). There was a trend for longer LT in patients with DM compared to those without DM (LT 1634 (130–2321) s vs. 1562 (1247–2147) s, p=0.080). After propensity score matching to adjust for baseline differences in clinical characteristics, we observed a highly significant difference in LT between DM and non-DM patients (LT 1634 [1306–2321] s vs. 1387 [1109–1740] s, p&lt;0.001). Patients with DM also had higher fibrinogen level (4.4 [3.5–5.4] vs. 4.1 [3.5–4.8] g/l, p=0.012) and higher C-reactive protein (5 [2–12] vs. 3 [1–8] mg/l, p=0.002). CRP correlated with LT (r=0.2, p=0.016), but no correlation was observed between fibrinogen and LT (r=0.069, p=0.424). Conclusions Amongst patients with ACS, those with DM exhibit markedly impaired endogenous fibrinolysis compared to those without DM, and this can be detected with a bedside assay using whole blood. This may explain the increased risk of secondary events in patients with ACS and DM. Funding Acknowledgement Type of funding source: None


2021 ◽  
Vol 15 (Supplement_1) ◽  
pp. S396-S397
Author(s):  
A Ametzazurra ◽  
J Pascual ◽  
L Del Rio ◽  
A Maguregui ◽  
D Nagore ◽  
...  

Abstract Background Promonitor Quick IFX is a lateral flow test (LFT) for the quantification of infliximab (IFX) in human whole blood (finger prick or venous) or serum in 20 minutes. This LFT is based on a sandwich immunoassay to quantify either the reference IFX or biosimilars. This abstract describes the studies performed to establish the analytical specifications of the product. Methods Clinical and Laboratory Standards Institute (CLSI) guidelines were followed for the evaluation of the analytical specifications of the LFT in whole blood and serum matrices: Linearity (EP-06-A), Detection capability (EP17-A2), Interfering substances (EP07, 3rd Edition), Intermediate precision (EP05-A3) and Bias evaluation study for Biosimilars (EP10-A3). Results were obtained in combination with the automated portable reader PQreader. A Datamatrix provided with each Promonitor Quick IFX kit contains the calibration information required for the PQreader to measure the Control and Test lines and report the IFX concentration. Results The linear assay range was determined to be 1-58 µg/mL in whole-blood and 0.6-67 µg/mL in serum according to the processes indicated in the Package Insert. The Limit of Blank is 0.8 μg/mL, the Limit of Detection and Lower Limit of Quantification (LLoQ) are 1.1 μg/mL, and the Upper Limit of Quantification (ULoQ) is 15.4 μg/mL. There was no effect on assay performance when each of the following substances were added to samples with 0, 3, and 7 μg/mL of IFX: Haemoglobin (&gt;1000 mg/dL), Bilirubin (&gt;40 mg/dL), Triglycerides (&gt;1500 mg/dL), HAMA (160 AU/mL), Rheumatoid factor (200 IU/mL), EDTA (5.4 mg/mL), Heparin (51 U/mL), Citrate (11.4%), Vedolizumab (60 μg/mL) and Adalimumab (20.25 μg/mL). Repeatability and within-device precision results obtained for the positive samples are shown in the table below. The negative samples showed a negative result in all the measurements. A bias study showed that Promonitor Quick IFX can quantify CT-P13, SB2 and GP1111 biosimilars throughout the measurement range with a maximum bias of 14%. Conclusion Promonitor Quick IFX is the first LFT available for true Point of Care testing of patients treated with IFX with just a finger prick sample. It provides quick turnaround time to facilitate therapeutic drug monitoring and aid immediate decision making in the doctor office or hospitals with an excellent analytical performance.


The Analyst ◽  
2018 ◽  
Vol 143 (18) ◽  
pp. 4422-4428 ◽  
Author(s):  
Jin Huang ◽  
Xue-Li Zhu ◽  
Yu-Min Wang ◽  
Jian-Hui Ge ◽  
Jin-Wen Liu ◽  
...  

In this work, a versatile point-of-care assay platform based on a microfluidic paper-based analytic device (μPAD) was developed for the simultaneous detection of multiple targets.


Sign in / Sign up

Export Citation Format

Share Document