scholarly journals Ruptured Echinococcus granulosus cysts in migrants: Is excessive antigen release causing false negative serology?

2020 ◽  
Vol 35 ◽  
pp. 101412
Author(s):  
Maarten J. Sarink ◽  
Perry J.J. van Genderen ◽  
Aloysius G.M. Tielens ◽  
Jaap J. van Hellemond
Methodology ◽  
2019 ◽  
Vol 15 (3) ◽  
pp. 97-105
Author(s):  
Rodrigo Ferrer ◽  
Antonio Pardo

Abstract. In a recent paper, Ferrer and Pardo (2014) tested several distribution-based methods designed to assess when test scores obtained before and after an intervention reflect a statistically reliable change. However, we still do not know how these methods perform from the point of view of false negatives. For this purpose, we have simulated change scenarios (different effect sizes in a pre-post-test design) with distributions of different shapes and with different sample sizes. For each simulated scenario, we generated 1,000 samples. In each sample, we recorded the false-negative rate of the five distribution-based methods with the best performance from the point of view of the false positives. Our results have revealed unacceptable rates of false negatives even with effects of very large size, starting from 31.8% in an optimistic scenario (effect size of 2.0 and a normal distribution) to 99.9% in the worst scenario (effect size of 0.2 and a highly skewed distribution). Therefore, our results suggest that the widely used distribution-based methods must be applied with caution in a clinical context, because they need huge effect sizes to detect a true change. However, we made some considerations regarding the effect size and the cut-off points commonly used which allow us to be more precise in our estimates.


2003 ◽  
Vol 42 (02) ◽  
pp. 71-77 ◽  
Author(s):  
I. Schreivogel ◽  
C. Angerstein ◽  
U. Siefker ◽  
K. Lehmann ◽  
G. Altenvoerde ◽  
...  

SummaryAim: Formal and clinical comparison of a new 3rd-gene-ration-Tg-IRMA (3-G-IRMA; Dynotest®Tg-plus) with a conventional Tg-IRMA (3-G-IRMA; SELco®Tg-assay) for patients with differentiated thyroid carcinoma. In addition we evaluated, if thyroglobulin (Tg) levels above a specific threshold concentration indicate the need for further investigations for residual disease. Patients, methods: Tg concentration of 105 sera of 93 consecutive patients with a differentiated thyroid cancer was determined with both assays and compared at different cut-off values (Dynotest®Tg-plus: 0.2, 1, 2 ng/ml; SELco®Tg-assay: 0.5, 1, 2 ng/ml) with the clinical results in respect to the corresponding TSH concentration. Results: Tg concentration did not show any significant difference (SELco®Tg-assay 0.5 ng/ml, Dynotest® Tg-plus 0.2 ng/ml). The Tg-values of both assays correlated with 97%. However, correlation of recovery in both assays was small (40%). The sensitivities and specificities of both assays at different cut-offs and TSH values did not reveal significant differences. In patients with TSH concentration >30 µU/ml the functional assay sensitivity was superior to arbitrary cut-offs in the decision to start further evaluations. Conclusions: In our study neither formal nor clinical significant differences between two Tg-assays were found. In a hypothyroid patient (TSH >30 µU/ml, Tg concentration exceeding the functional assay sensitivity) further investigations for residual disease are warranted. Higher thresholds are of limited value, due to a inacceptable high rate of false negative results.


1974 ◽  
Vol 31 (02) ◽  
pp. 273-278
Author(s):  
Kenneth K Wu ◽  
John C Hoak ◽  
Robert W Barnes ◽  
Stuart L Frankel

SummaryIn order to evaluate its daily variability and reliability, impedance phlebography was performed daily or on alternate days on 61 patients with deep vein thrombosis, of whom 47 also had 125I-fibrinogen uptake tests and 22 had radiographic venography. The results showed that impedance phlebography was highly variable and poorly reliable. False positive results were noted in 8 limbs (18%) and false negative results in 3 limbs (7%). Despite its being simple, rapid and noninvasive, its clinical usefulness is doubtful when performed according to the original method.


Sign in / Sign up

Export Citation Format

Share Document