Interfacial microstructure and defect analysis in Cu(In,Ga)Se([sub]2)-based multilayered film by analytical transmission electron microscopy and focused ion beam

2009 ◽  
Vol 517 (15) ◽  
pp. 4329-4335 ◽  
Author(s):  
Zaoli Zhang ◽  
Thomas Wagner
1999 ◽  
Vol 5 (S2) ◽  
pp. 900-901
Author(s):  
R. Pantel ◽  
G. Mascarin ◽  
G. Auvert

1. Introduction.With continuing reductions in semiconductor device dimensions high spatial resolution physical and chemical analysis techniques will be more and more required for defect analysis and process development in the microelectronics field. Transmission Electron Microscopy (TEM) analysis is now extensively used thanks to the fast Focused Ion Beam (FIB) specimen preparation technique which has furthered its development. Recently, we have shown the advantages of adding Electron Energy Loss Spectroscopy (EELS) to FIB-TEM analysis for semiconductor process characterization. In this paper we extend the EELS technique using FIB sample preparation to Energy Filtering TEM (EFTEM) observations. The EFTEM analysis allows high-resolution compositional mapping using spectroscopic imaging of core level ionization edges3. We show some applications of FIB-EFTEM to defect analysis and process development.2. Experimental details.The FIB system is a MICRION model 9500 EX using a gallium ion beam of 50 keV maximum energy with a 5 nm minimum spot diameter.


Author(s):  
Ching Shan Sung ◽  
Hsiu Ting Lee ◽  
Jian Shing Luo

Abstract Transmission electron microscopy (TEM) plays an important role in the structural analysis and characterization of materials for process evaluation and failure analysis in the integrated circuit (IC) industry as device shrinkage continues. It is well known that a high quality TEM sample is one of the keys which enables to facilitate successful TEM analysis. This paper demonstrates a few examples to show the tricks on positioning, protection deposition, sample dicing, and focused ion beam milling of the TEM sample preparation for advanced DRAMs. The micro-structures of the devices and samples architectures were observed by using cross sectional transmission electron microscopy, scanning electron microscopy, and optical microscopy. Following these tricks can help readers to prepare TEM samples with higher quality and efficiency.


Author(s):  
K. Doong ◽  
J.-M. Fu ◽  
Y.-C. Huang

Abstract The specimen preparation technique using focused ion beam (FIB) to generate cross-sectional transmission electron microscopy (XTEM) samples of chemical vapor deposition (CVD) of Tungsten-plug (W-plug) and Tungsten Silicides (WSix) was studied. Using the combination method including two axes tilting[l], gas enhanced focused ion beam milling[2] and sacrificial metal coating on both sides of electron transmission membrane[3], it was possible to prepare a sample with minimal thickness (less than 1000 A) to get high spatial resolution in TEM observation. Based on this novel thinning technique, some applications such as XTEM observation of W-plug with different aspect ratio (I - 6), and the grain structure of CVD W-plug and CVD WSix were done. Also the problems and artifacts of XTEM sample preparation of high Z-factor material such as CVD W-plug and CVD WSix were given and the ways to avoid or minimize them were suggested.


Author(s):  
Chin Kai Liu ◽  
Chi Jen. Chen ◽  
Jeh Yan.Chiou ◽  
David Su

Abstract Focused ion beam (FIB) has become a useful tool in the Integrated Circuit (IC) industry, It is playing an important role in Failure Analysis (FA), circuit repair and Transmission Electron Microscopy (TEM) specimen preparation. In particular, preparation of TEM samples using FIB has become popular within the last ten years [1]; the progress in this field is well documented. Given the usefulness of FIB, “Artifact” however is a very sensitive issue in TEM inspections. The ability to identify those artifacts in TEM analysis is an important as to understanding the significance of pictures In this paper, we will describe how to measure the damages introduced by FIB sample preparation and introduce a better way to prevent such kind of artifacts.


Sign in / Sign up

Export Citation Format

Share Document