Validation of analytical method and evaluation of clothianidin residues in rice in a typical Chinese field ecosystem

2017 ◽  
Vol 155 (9) ◽  
pp. 1371-1380 ◽  
Author(s):  
Z. Y. ZHANG ◽  
Z. T. ZHENG ◽  
G. Y. ZHU ◽  
X. Y. YU ◽  
D. L. WANG ◽  
...  

SUMMARYA liquid chromatography mass spectrometry method for determination of clothianidin in brown rice, straw, rice hull, paddy water and paddy sediment was developed and residue levels were determined in the different components. The limit of quantification was set at 0·01 mg/kg for the matrices studied. Clothianidin degradation in straw, paddy water and soil was studied, and clothianidin residues in brown rice, straw, hull and paddy soil were determined. Concurrent recoveries were between 85·6 and 92·5%, with relative standard deviations ranging from 1·3 to 6·8% at three fortification levels between 0·01 and 5·0 mg/kg. The half-lives in straw, paddy water and paddy sediment were found to be 1·9–4·9, 4·1–5·0 and 4·9–6·3 days, respectively. The maximum residues in brown rice, straw, hull and paddy soil samples were 0·38, 1·88, 1·38 and 0·14 mg/kg, respectively.

2020 ◽  
Vol 2020 ◽  
pp. 1-8
Author(s):  
Ying-Hong Li ◽  
Xiang-Yun Wang ◽  
Wei Hua ◽  
Hu Zhang

Indoxacarb is a broad-spectrum insecticide and widely used in agriculture. The dissipations and residues of indoxacarb were researched at three different field sites in Beijing, Hunan, and Zhejiang provinces in China. Analytical methods for determining the residue of indoxacarb in paddy water, paddy soil, rice straw, rice hull, and brown rice were described. Indoxacarb residues were extracted from samples, cleaned up by solid phase extraction, and determined by high-performance liquid chromatography coupled with tandem mass spectrometry in the selected ion monitoring mode. The recoveries in paddy water, paddy soil, rice straw, rice hull, and brown rice matrices at three spiking levels ranged from 79.7% to 98.3%, respectively. The field and environmental conditions would affect the dissipations and residues of indoxacarb. The time to dissipate 50% of indoxacarb in paddy water, paddy soil, and rice straw was less than 9 days. The terminal residues obtained from Beijing at preharvest interval of 14 and 21 days were higher than the maximum limit of European Union. Therefore, a dosage of 24 g a. i. ha−1 at 28 days preharvest interval with 3 spraying times was recommended. Such accumulation of measured data is necessary to provide guidance for the proper and safe use of this pesticide.


2020 ◽  
Vol 16 (4) ◽  
pp. 428-435
Author(s):  
Ahmed F.A. Youssef ◽  
Yousry M. Issa ◽  
Kareem M. Nabil

Background: Simeprevir is one of the recently discovered drugs for treating hepatitis C which is one of the major diseases across the globe. Objective: The present study involves the development of a new and unique High-Performance Liquid Chromatography (HPLC) method using fluorescence detection for the determination of simeprevir (SIM) in human plasma. Methods: Two methods of extractions were tested, protein precipitation using acetonitrile and liquidliquid extraction. A 25 mM dipotassium hydrogen orthophosphate (pH 7.0)/ACN (50/50; v/v), was used as mobile phase and C18 reversed phase column as the stationary phase. The chromatographic conditions were optimized and the concentration of simeprevir was determined by using the fluorescence detector. Cyclobenzaprine was used as an internal standard. Results: Recovery of the assay method based on protein precipitation was up to 100%. Intra-day and inter-day accuracies range from 92.30 to 107.80%, with Relative Standard Deviation (RSD) range 1.65-8.02%. The present method was successfully applied to a pharmacokinetic study where SIM was administered as a single dose of 150 mg SIM/capsule (Olysio®) to healthy individuals. Conclusion: This method exhibits high sensitivity with a low limit of quantification 10 ng mL-1, good selectivity using fluorescence detection, wide linear application range 10-3000 ng mL-1, good recovery and highly precise and validation results. The developed method can be applied in routine analysis for real samples.


2021 ◽  
Vol 7 (1) ◽  
Author(s):  
Indhu Priya Mabbu ◽  
G. Sumathi ◽  
N. Devanna

Abstract Background The aim of the present method is to develop and validate a specific, sensitive, precise, and accurate liquid chromatography-mass spectrometry (LC-MS) method for the estimation of the phenyl vinyl sulfone in the eletriptan hydrobromide. The effective separation of the phenyl vinyl sulfone was achieved by the Symmetry C18 (50 × 4.6 mm, 3.5 μm) column and a mobile phase composition of 0.1%v/v ammonia buffer to methanol (5:95 v/v), using 0.45 ml/min flow rate and 20 μl of injection volume, with methanol used as diluent. The phenyl vinyl sulfone was monitored on atomic pressure chemical ionization mode mass spectrometer with positive polarity mode. Results The retention time of phenyl vinyl sulfone was found at 2.13 min. The limit of detection (LOD) and limit of quantification (LOQ) were observed at 1.43 ppm and 4.77 ppm concentration respectively; the linear range was found in the concentration ranges from 4.77 to 27.00 ppm with regression coefficient of 0.9990 and accuracy in the range of 97.50–102.10%. The percentage relative standard deviation (% RSD) for six replicates said to be injections were less than 10%. Conclusion The proposed method was validated successfully as per ICH guidelines. Hence, this is employed for the determination of phenyl vinyl sulfone in the eletriptan hydrobromide.


Molecules ◽  
2021 ◽  
Vol 26 (7) ◽  
pp. 1837
Author(s):  
Harischandra Naik Rathod ◽  
Bheemanna Mallappa ◽  
Pallavi Malenahalli Sidramappa ◽  
Chandra Sekhara Reddy Vennapusa ◽  
Pavankumar Kamin ◽  
...  

A quick, sensitive, and reproducible analytical method for the determination of 77 multiclass pesticides and their metabolites in Capsicum and tomato by gas and liquid chromatography tandem mass spectrometry was standardized and validated. The limit of detection of 0.19 to 10.91 and limit of quantification of 0.63 to 36.34 µg·kg−1 for Capsicum and 0.10 to 9.55 µg·kg−1 (LOD) and 0.35 to 33.43 µg·kg−1 (LOQ) for tomato. The method involves extraction of sample with acetonitrile, purification by dispersive solid phase extraction using primary secondary amine and graphitized carbon black. The recoveries of all pesticides were in the range of 75 to 110% with a relative standard deviation of less than 20%. Similarly, the method precision was evaluated interms of repeatability (RSDr) and reproducibility (RSDwR) by spiking of mixed pesticides standards at 100 µg·kg−1 recorded anRSD of less than 20%. The matrix effect was acceptable and no significant variation was observed in both the matrices except for few pesticides. The estimated measurement uncertainty found acceptable for all the pesticides. This method found suitable for analysis of vegetable samples drawn from market and farm gates.


2012 ◽  
Vol 11 (1) ◽  
pp. 55-63 ◽  
Author(s):  
Maizbha Uddin Ahmed ◽  
Mohammad Safiqul Islam ◽  
Tasmin Ara Sultana ◽  
AGM Mostofa ◽  
Muhammad Shahdaat Bin Sayeed ◽  
...  

Azithromycin is an effective and well-known antimicrobial agent. In the present study, a simple, sensitive and specific LC/MS/MS method has been developed and validated for the quantification of Azithromycin in  human serum samples using Clarithromycin as internal standard. Azithromycin was extracted from biological matrix  by using solid phase extraction process. The chromatographic separation was performed on Luna C18 (3 ?, 2x150   mm) column with a mobile phase consisting of 35 mM ammonium acetate buffer (mobile phase-A) and acetonitrile  and methanol in ratio of 90:10 ( as mobile phase-B) at a flow rate of 0.25 mL/min. The method was validated over a  linear concentration range of 0.5?50.0 ng/mL and limit of quantification (LOQ) was 0.5 ng/mL with a coefficient of  correlation (r2) = 0.9998. The intra-day and inter-day precision expressed as relative standard deviation were 1.64% – 8.43% and 2.32% – 9.92%, respectively. The average recovery of azithromycin from serum was 98.11%. The method  was successfully applied to a pharmacokinetic study after oral administration of Azithromycin 200 mg/5 ml suspension in healthy Bangladeshi volunteers. DOI: http://dx.doi.org/10.3329/dujps.v11i1.12488 Dhaka Univ. J. Pharm. Sci. 11(1): 55-63, 2012 (June)


2003 ◽  
Vol 68 (8-9) ◽  
pp. 691-698 ◽  
Author(s):  
Milena Jelikic-Stankov ◽  
Predrag Djurdjevic ◽  
Dejan Stankov

In this work a new enzymatic method for the determination of uric acid in human serum has been developed. The method is based on the oxidative coupling reaction between the N-methyl-N-(4-aminophenyl)-3-methoxyaniline (NCP) reagent and the hydrogen ? donor reagent N-ethyl-N-(2-hydroxy-3-sulfopropyl)-3-methylaniline (TOOS), in the system involving three enzymes: uricase, peroxidase and ascorbate oxidase. Using this method uric acid could be determined in concentrations up to 1.428 mmol/L, with a relative standard deviation of up to 1.8 %. The effect of the medium pH and the NCP concentration on the linearity of the chromogen absorbance versus the uric acid concentration curve was investigated. The influence of the uricase activity on the maximum rate of uric acid oxidation was also examined. The use of the NCP reagent demonstrated a more precise and more sensitive determination of the uric acid compared to the determination with 4-aminoantipyrine (4-AA) as the coupling regent. The sensitivity of the method determined from the calibration curve was 0.71 absorbance units per mmol/L of uric acid; the limit of detection was LOD = 0.0035 mmol/L and the limit of quantification was LOQ = 0.015 mmol/L of uric acid.


2015 ◽  
Vol 12 (1) ◽  
pp. 167-177 ◽  
Author(s):  
Baghdad Science Journal

A spectrophotometric method has been proposed for the determination of two drugs containing phenol group [phenylephrine hydrochloride (PHP) and salbutamol sulphate (SLB)] in pharmaceutical dosage forms. The method is based on the diazotization reaction of metoclopramide hydrochloride (MCP) and coupling of the diazotized reagent with drugs in alkaline medium to give intense orange colored product (?max at 470 nm for each of PHP and SLB). Variable parameters such as temperature, reaction time and concentration of the reactants have been analyzed and optimized. Under the proposed optimum condition, Beer’s law was obeyed in the concentration range of 1-32 and 1-14 ?g mL-1 for PHP and SLB, respectively. The limit of detection (LOD) and limit of quantification (LOQ) for each of PHP and SLB were 0.60, 0.52 ?g mL-1 and 2.02, 1.72 ?g mL-1, respectively. No interference was observed from common excipients present in pharmaceutical preparations. The good correlation coefficients and low relative standard deviation assert the applicability of this method. The suggested method was further applied for the determinations of drugs in commercial pharmaceutical preparations, which was compared statistically with reference methods by means of t- test and F- test and were found not to differ significantly at 95% confidence level. The procedure was characterized by its simplicity with accuracy and precision.


2013 ◽  
Vol 829 ◽  
pp. 825-830 ◽  
Author(s):  
Ali Mazloomifar ◽  
Nafiseh Khatibi

The liquid-phase microextraction based on solidification of floating organic microdrop coupled with UV-visible spectrophotometer for preconcentration and determination of lead in the aqueous samples has been developed. In this technique, 20μL of 1-undecanol containing dithizone as the chelating agent (10-3mol L-1) was transferred to the water samples containing lead ions, and the solution was stirred for 25 min. The sample vial was cooled in an ice bath for 5 min. The solidified extract was transferred into a conical vial where it melted immediately, and then the organic phase was analyzed by Nanodrop spectrophotometer. Factors that influence the extraction and complex formation, such as pH, concentration of dithizone, extraction time, effect of ionic strenght, temperature and stirring rate were optimized. Under the optimized conditions, a preconcentration factor of 356, detection limit of 0.006 μgL-1, limit of quantification 0.018 μgL-1and a good relative standard deviation of 2.1% were obtained. The procedure was applied to sea water, mineral water and well water.


2021 ◽  
Author(s):  
Tao Lin ◽  
Xinglian Chen ◽  
Li Wang ◽  
Haixian Fang ◽  
Maoxuan Li ◽  
...  

Abstract The simultaneous determination method of 8 amide pesticides by multi-walled carbon nanotubes (MWCNs) cleanup, combined with QuEChERS method and ultra-high performance liquid chromatography-triple quadrupole tandem mass spectrometry has been developed and successfully applied in complex matrix such as green onions, celery, leeks, citrus, lychees, avocado. The matric effect of MWCNs is optimized and compared with QuEChERS materials. The results show that MWCNs can effectively reduce the matrix effect in sample extraction. The mass spectrometry is optimized, through their chemical structure skeletons, the ESI+ and ESI- mode are simultaneously scanned in the method. The coefficient (r) is greater than 0.9990, the limit of quantification ranges from 0.03 to 0.80 μg/kg, the recovery rate ranges from 71.2% to 120%, and the relative standard deviation (RSD) ranges from 3.8% to 9.4%. The method is fast, simple, sensitive, and has good purification effect. It is suitable for the rapid determination of amide pesticides in complex matrix agri-food.


2005 ◽  
Vol 88 (6) ◽  
pp. 1834-1839 ◽  
Author(s):  
Nicholas G Tsiropoulos ◽  
Konstantinos Liapis ◽  
Dimitrios T Likas ◽  
George E Miliadis

Abstract Analytical methodology was developed and validated for the determination of spiroxamine residues in grapes, must, and wine by gas chromatography/ion trap-mass spectrometry (GC/IT-MS). Two extraction procedures were used: the first involved grapes, must, and wine extraction with alkaline cyclohexane–dichloromethane (9 + 1, v/v) solution, and the second grape extraction with acetone, dichloromethane, and petroleum ether. In both procedures, the extract was centrifuged, evaporated to dryness, and reconstituted in cyclohexane or 2,2,4-trimethylpentane–toluene (9 + 1, v/v), respectively. Spiroxamine diastereomers A and B were determined by GC/IT-MS, and a matrix effect was observed in the case of grapes but not in must and wine. Recovery of spiroxamine from fortified samples at 0.02 to 5.0 mg/kg ranged from 78–102% for grapes and must, with relative standard deviation (RSD) <13%; for red and white wines, recoveries ranged from 90 to 101% with RSD <9%. The limit of quantification was 0.02 mg/kg for grapes, must, and wine or 0.10 mg/kg for grapes, depending on the extraction procedure used.


Sign in / Sign up

Export Citation Format

Share Document