Flow structures and particle deposition patterns in double-bifurcation airway models. Part 2. Aerosol transport and deposition

2001 ◽  
Vol 435 ◽  
pp. 55-80 ◽  
Author(s):  
J. K. COMER ◽  
C. KLEINSTREUER ◽  
C. S. KIM

The flow theory and air flow structures in symmetric double-bifurcation airway models assuming steady laminar, incompressible flow, unaffected by the presence of aerosols, has been described in a companion paper (Part 1). The validated computer simulation results showed highly vortical flow fields, especially around the second bifurcations, indicating potentially complex particle distributions and deposition patterns. In this paper (Part 2), assuming spherical non-interacting aerosols that stick to the wall when touching the surface, the history of depositing particles is described. Specifically, the finite-volume code CFX (AEA Technology) with user-enhanced FORTRAN programs were validated with experimental data of particle deposition efficiencies as a function of the Stokes number for planar single and double bifurcations. The resulting deposition patterns, particle distributions, trajectories and time evolution were analysed in the light of the air flow structures for relatively low (ReD1 = 500) and high (ReD1 = 2000) Reynolds numbers and representative Stokes numbers, i.e. StD1 = 0.04 and StD1 = 0.12. Particle deposition patterns and surface concentrations are largely a function of the local Stokes number, but they also depend on the fluid–particle inlet conditions as well as airway geometry factors. While particles introduced at low inlet Reynolds numbers (e.g. ReD1 = 500) follow the axial air flow, secondary and vortical flows become important at higher Reynolds numbers, causing the formation of particle-free zones near the tube centres and subsequently elevated particle concentrations near the walls. Sharp or mildly rounded carinal ridges have little effect on the deposition efficiencies but may influence local deposition patterns. In contrast, more drastic geometric changes to the basic double-bifurcation model, e.g. the 90°-non-planar configuration, alter both the aerosol wall distributions and surface concentrations considerably.

2001 ◽  
Vol 435 ◽  
pp. 25-54 ◽  
Author(s):  
J. K. COMER ◽  
C. KLEINSTREUER ◽  
Z. ZHANG

The understanding and quantitative assessment of air flow fields and local micron-particle wall concentrations in tracheobronchial airways are very important for estimating the health risks of inhaled particulate pollutants, developing algebraic transfer functions of global lung deposition models used in dose-response analyses, and/or determining proper drug-aerosol delivery to target sites in the lung. In this paper (Part 1) the theory, model geometries, and air flow results are provided. In a companion paper (Part 2, Comer et al. 2001), the history of particle deposition patterns and comparisons with measured data sets are reported. Decoupling of the naturally dilute particle suspension makes it feasible to present the results in two parts.Considering a Reynolds number range of 500 [les ] ReD [les ] 2000, it is assumed that the air flow is steady, incompressible and laminar and that the tubular double bifurcations, i.e. Weibel's generations G3–G5, are three-dimensional, rigid, and smooth with rounded as well as sharp carinal ridges for symmetric planar, and just rounded carinas for 90° non-planar configurations. The employed finite-volume code CFX (AEA Technology) and its user-enhanced FORTRAN programs were validated with experimental velocity data points for a single bifurcation. The resulting air flow structures are analysed for relatively low (ReD = 500) and high (ReD = 2000) Reynolds numbers. Sequential pressure drops due to viscous effects were calculated and compared, extending a method proposed by Pedley et al. (1977). Such detailed results for bifurcating lung airways are most useful in the development of global algebraic lung models.


1999 ◽  
Vol 122 (2) ◽  
pp. 152-158 ◽  
Author(s):  
J. K. Comer ◽  
C. Kleinstreuer ◽  
S. Hyun ◽  
C. S. Kim

Deposition patterns and efficiencies of a dilute suspension of inhaled particles in three-dimensional double bifurcating airway models for both in-plane and 90 deg out-of-plane configurations have been numerically simulated assuming steady, laminar, constant-property air flow with symmetry about the first bifurcation. Particle diameters of 3, 5, and 7 μm were used in the simulation, while the inlet Stokes and Reynolds numbers varied from 0.037 to 0.23 and 500 to 2000, respectively. Comparisons between these results and experimental data based on the same geometric configuration showed good agreement. The overall trend of the particle deposition efficiency, i.e., an exponential increase with Stokes number, was somewhat similar for all bifurcations. However, the deposition efficiency of the first bifurcation was always larger than that of the second bifurcation, while in general the particle efficiency of the out-of-plane configuration was larger than that of the in-plane configuration. The local deposition patterns consistently showed that the majority of the deposition occurred in the carinal region. The distribution pattern in the first bifurcation for both configurations were symmetric about the carina, which was a direct result of the uniaxial flow at the inlet. The deposition patterns about the second carina showed increased asymmetry due to highly nonuniform flow generated by the first bifurcation and were extremely sensitive to bifurcation orientation. Based on the deposition variations between bifurcation levels and orientations, the use of single bifurcation models was determined to be inadequate to resolve the complex fluid–particle interactions that occur in multigenerational airways. [S0148-0731(00)01102-X]


2011 ◽  
Vol 84-85 ◽  
pp. 91-95
Author(s):  
Qi Li ◽  
Chuan Shan Dai ◽  
Wen Jing Jiao

This paper investigates numerically the motion and deposition behaviors of micro- or nano-scaled particles in fluid passing three different kinds of square pores. The three kinds of square pores represent different pore structures in porous medium. The flow fields are numerically simulated by lattice Boltzmann method (LBM). The computation procedure code was validated by comparing the results with those of the previous works for the case of particle fluid passing a square block in a two dimensional channel flow. The results show that the dispersion of particles in three different square pore structures are much different, and vary with Stokes numbers for the same square pore even the Reynolds numbers are the same. In addition, the number and the position of deposited particles are analyzed. It shows that the deposition characteristics of each wall are mainly influenced by Stokes number, Reynolds number and the pore structure.


2021 ◽  
Vol 13 (5) ◽  
pp. 168781402110178
Author(s):  
Zhengang Liu ◽  
Weinan Diao ◽  
Zhenxia Liu ◽  
Fei Zhang

Particle deposition could decrease the aerodynamic performance and cooling efficiency of turbine vanes and blades. The particle motion in the flow and its temperature are two important factors affecting its deposition. The size of the particle influences both its motion and temperature. In this study, the motion of particles with the sizes from 1 to 20 μm in the first stage of a turbine are firstly numerically simulated with the steady method, then the particle deposition on the vanes and blades are numerically simulated with the unsteady method based on the critical viscosity model. It is discovered that the particle deposition on vanes mainly formed near the leading and trailing edge on the pressure surface, and the deposition area expands slowly to the whole pressure surface with the particle size increasing. For the particle deposition on blades, the deposition area moves from the entire pressure surface toward the tip with the particle size increasing due to the effect of rotation. For vanes, the particle capture efficiency increases with the particle size increasing since Stokes number and temperature of the particle both increase with its size. For blades, the particle capture efficiency increases firstly and then decreases with the particle size increasing.


2021 ◽  
Author(s):  
François Yaya ◽  
Johannes Römer ◽  
Achim Guckenberger ◽  
Thomas John ◽  
Stephan Gekle ◽  
...  

2000 ◽  
Vol 122 (2) ◽  
pp. 403-411 ◽  
Author(s):  
P. W. Longest, ◽  
C. Kleinstreuer ◽  
J. S. Kinsey

Steady incompressible turbulent air flow and transient carbon monoxide transport in an empty Rochester-style human exposure chamber have been numerically simulated and compared with experimental data sets. The system consisted of an inlet duct with a continuous carbon monoxide point source, 45- and 90-degree bends, a round diffuser, a round-to-square transition, a rectangular diffuser, the test chamber, a perforated floor, and again transition pieces from the chamber to an outlet duct. Such a configuration induced highly nonuniform vortical flow patterns in the chamber test area where a pollutant concentration is required to be constant at breathing level for safe and accurate inhalation studies. Presented are validated momentum and mass transfer results for this large-scale system with the main goals of determining the development of tracer gas (CO) distributions in the chamber and analyzing the contributions to CO-mixing. Numerical simulations were conducted employing a k-ε model and the latest available RNG k-ε model for air and CO-mixing. Both models predict similar velocity fields and are in good agreement with measured steady and transient CO-concentrations. It was found that secondary flows in the inlet section and strong vortical flow in the chamber with perforated flooring contributed to effective mixing of the trace gas at breathing levels. Specifically, in the height range of 1.4 m<h<2.0 m above the chamber floor, predicted CO-concentrations rapidly reached a near constant value which agrees well with experimental results. This work can be extended to analyze trace gas mixing as well as aerosol dispersion in occupied test chambers with or without flow redirection devices installed in the upstream section. A complementary application is particle transport and deposition in clean rooms of the electronic, pharmaceutical, and health care industries. [S0098-2202(00)01702-8]


Author(s):  
J. W. Douglas ◽  
S.-M. Li ◽  
B. Song ◽  
W. F. Ng ◽  
Toyotaka Sonoda ◽  
...  

Very little published literature documents the effects of different freestream turbulence intensities on compressor flows at realistically high Reynolds numbers. This paper presents a study of these effects on a transonic, linear, compressor stator cascade. The cascade consisted of high turning stator airfoils that had the camber of 55 degrees. The effects of freestream turbulence intensities of approximately 0.1% (baseline) and 1.6% were examined. Inlet Mach numbers to the cascade were tested from 0.55 to 0.89. Reynolds numbers, based on the inlet conditions and blade chord, varied between 1.0–2.0×106. Inlet flow angles to the cascade ranged from a choking to a stall condition. For the baseline cases, at most positive incidence angles to the cascade, surface oil flow visualization and Schlieren pictures showed a significant flow separation on the suction surface of the blade. Under these conditions, the increase in freestream turbulence from 0.1% to 1.6% significantly reduced the flow losses of the cascade (by as much as 57% in some cases). In other test conditions where no evidence depicted flow separation on the blade, there were no measurable effects on the losses due to the increase in freestream turbulence intensity. In addition, the increase of freestream turbulence intensity also improved the effective operating range of the cascade significantly (e.g., by 46% or higher).


Author(s):  
Lara Schembri Puglisevich ◽  
Gary Page

Unsteady Large Eddy Simulation (LES) is carried out for the flow around a bluff body equipped with an underbody rear diffuser in close proximity to the ground, representing an automotive diffuser. The goal is to demonstrate the ability of LES to model underbody vortical flow features at experimental Reynolds numbers (1.01 × 106 based on model height and incoming velocity). The scope of the time-dependent simulations is not to improve on Reynolds-Averaged Navier Stokes (RANS), but to give further insight into vortex formation and progression, allowing better understanding of the flow, hence allowing more control. Vortical flow structures in the diffuser region, along the sides and top surface of the bluff body are successfully modelled. Differences between instantaneous and time-averaged flow structures are presented and explained. Comparisons to pressure measurements from wind tunnel experiments on an identical bluff body model shows a good level of agreement.


2019 ◽  
Vol 11 (3) ◽  
pp. 751
Author(s):  
Hao Lu ◽  
Li-zhi Zhang

Dry deposition of airborne particles in duct air flow over a backward-facing step (BFS) is commonly encountered in built environments and energy engineering. However, the understanding of particle deposition characteristics in BFS flow remains insufficient. Thus, this study investigated particle deposition behaviors and efficiency in BFS flow by using the Reynolds stress model and the discrete particle model. The influences of flow velocities, particle diameters, and duct expansion ratios on particle deposition characteristics were examined and analyzed. After numerical validation, particle deposition velocities, deposition efficiency, and deposition mechanisms in BFS duct flow were investigated in detail. The results showed that deposition velocity in BFS duct flow monotonically increases when particle diameter increases. Moreover, deposition velocity falls with increasing expansion ratio but rises with increasing air velocity. Deposition efficiency, the ratio of deposition velocity, and flow drag in a BFS duct is higher for small particles but lower for large particles as compared with a uniform duct. A higher particle deposition efficiency can be achieved by BFS with a smaller expansion ratio. The peak deposition efficiency can reach 33.6 times higher for 1-μm particles when the BFS expansion ratio is 4:3. Moreover, the “particle free zone” occurs for 50-μm particles in the BFS duct and is enlarged when the duct expansion ratio increases.


Sign in / Sign up

Export Citation Format

Share Document