scholarly journals Improvements to ion-correlation experiments in dense plasmas

1992 ◽  
Vol 10 (1) ◽  
pp. 41-51 ◽  
Author(s):  
B. A. Shiwai ◽  
A. Djaoui ◽  
T. A. Hall ◽  
G. J. Tallents ◽  
S. J. Rose

Improved measurements of ion-correlation effects in a dense shock-compressed plasma are presented. The extended X-ray-absorption fine-structure (EXAFS) technique on the aluminum K edge is used to observe the short-range order within a dense plasma. Densities of about three times solid density were measured with good accuracy. The experimental measurements of density give results that are in good agreement with the MEDUSA onedimensional fluid code predictions. The improved quality of the data enabled us to calculate the ion coupling parameter during the compression and the subsequent heating of the plasma. An estimation of the temperature is given on the basis of published models, and an approximate agreement is obtained with the MEDUSA code predictions.

2010 ◽  
Vol 43 (2) ◽  
pp. 227-236 ◽  
Author(s):  
Leandro M. Acuña ◽  
Diego G. Lamas ◽  
Rodolfo O. Fuentes ◽  
Ismael O. Fábregas ◽  
Márcia C. A. Fantini ◽  
...  

The local atomic structures around the Zr atom of pure (undoped) ZrO2nanopowders with different average crystallite sizes, ranging from 7 to 40 nm, have been investigated. The nanopowders were synthesized by different wet-chemical routes, but all exhibit the high-temperature tetragonal phase stabilized at room temperature, as established by synchrotron radiation X-ray diffraction. The extended X-ray absorption fine structure (EXAFS) technique was applied to analyze the local structure around the Zr atoms. Several authors have studied this system using the EXAFS technique without obtaining a good agreement between crystallographic and EXAFS data. In this work, it is shown that the local structure of ZrO2nanopowders can be described by a model consisting of two oxygen subshells (4 + 4 atoms) with different Zr—O distances, in agreement with those independently determined by X-ray diffraction. However, the EXAFS study shows that the second oxygen subshell exhibits a Debye–Waller (DW) parameter much higher than that of the first oxygen subshell, a result that cannot be explained by the crystallographic model accepted for the tetragonal phase of zirconia-based materials. However, as proposed by other authors, the difference in the DW parameters between the two oxygen subshells around the Zr atoms can be explained by the existence of oxygen displacements perpendicular to thezdirection; these mainly affect the second oxygen subshell because of the directional character of the EXAFS DW parameter, in contradiction to the crystallographic value. It is also established that this model is similar to another model having three oxygen subshells, with a 4 + 2 + 2 distribution of atoms, with only one DW parameter for all oxygen subshells. Both models are in good agreement with the crystal structure determined by X-ray diffraction experiments.


2012 ◽  
Vol 20 (1) ◽  
pp. 166-171
Author(s):  
Vasil Koteski ◽  
Jelena Belošević-Čavor ◽  
Petro Fochuk ◽  
Heinz-Eberhard Mahnke

The lattice relaxation around Ga in CdTe is investigated by means of extended X-ray absorption spectroscopy (EXAFS) and density functional theory (DFT) calculations using the linear augmented plane waves plus local orbitals (LAPW+lo) method. In addition to the substitutional position, the calculations are performed for DX- and A-centers of Ga in CdTe. The results of the calculations are in good agreement with the experimental data, as obtained from EXAFS and X-ray absorption near-edge structure (XANES). They allow the experimental identification of several defect structures in CdTe. In particular, direct experimental evidence for the existence of DX-centers in CdTe is provided, and for the first time the local bond lengths of this defect are measured directly.


1999 ◽  
Vol 5 (S2) ◽  
pp. 708-709
Author(s):  
Y. Ito ◽  
H. Jain ◽  
D.B. Williams

Small atomic clusters are of great importance for applications such as catalysts whose activity depends on the surface of the cluster. Attempts to determine the atomic short-range order and size of clusters have been made by analyzing the extended X-ray absorption fine structure (EXAFS). However, the analysis was made on an average of many small clusters. Analysis of extended energy-loss fine structure (EXELFS) in an electron energy-loss spectrum (EELS) has developed to the point where in some cases, the quality of the results is comparable to its X-ray analogue, EXAFS. No other technique provides nanometer-scale spatial resolution of the analyzed area for determining the atomic structure. Most EXELFS analysis has been performed on the K-ionization edge of lighter elements. For heavier elements, a more complex ionization edge such as the L-edge has to be used, due to the inefficiency of collecting high quality EEL spectra at higher energy-losses (Z > 18).


2004 ◽  
Vol 22 (1) ◽  
pp. 25-28 ◽  
Author(s):  
O. RENNER ◽  
I. USCHMANN ◽  
E. FÖRSTER

Modern experimental methods and instruments for X-ray spectral investigation of hot dense plasma provide complex information on environmental conditions in extreme states of matter. The basic spectroscopic conceptions for K-shell plasma diagnosis are outlined, the main characteristics of toroidally bent crystal spectrometers and vertical-dispersion instruments are briefly reviewed. Selected applications (monitoring and optimization of the emission from the femtosecond-laser-produced plasmas, characterization of colliding laser-exploded foils, spectral line merging, and continuum lowering in constrained-flow plasmas) demonstrate the usefulness of advanced spectroscopic methods for plasma diagnostics and fundamental research.


1998 ◽  
Vol 16 (1) ◽  
pp. 21-30 ◽  
Author(s):  
P. Angelo ◽  
H. Derfoul ◽  
P. Gauthier ◽  
P. Sauvan ◽  
A. Poquerusse ◽  
...  

We create hot (Te > 200 eV) and dense (Ne > 1023 cm−3) plasmas in the colliding zone of two thin foils accelerated by two laser beams of the LULI facilities. Three spectroscopic diagnostics (two 1D space-resolved spectrographs and a 2D monochromatic imaging) are used to drive the efficiency of the compression. We show that 2D effects are important. Realistic simulations of these experiments must be done, taking into account the inhomogeneity of the laser intensity in the focal spot, the foil distorsion, the plasma lateral expansion, and the lateral thermal conduction. Two-dimensional LASNEX code results are in good agreement with our experimental results. The optimized compressed plasmas generated are favorable for the exhibition of dense plasma effects due to molecular formations, and they reproduce in laboratory some astrophysical situations.


1985 ◽  
Vol 61 ◽  
Author(s):  
Farrel W. Lytle ◽  
Robert B. Greegor

ABSTRACTX-ray absorption spectroscopy is used to determine valence and site symmetry for all the 3d transition metals in fused quartz prepared by the flame hydrolysis method. The results are compared with optical data on the same samples with generally good agreement.


1989 ◽  
Vol 44 (3) ◽  
pp. 189-194
Author(s):  
P. Kizler ◽  
P. Lamparter ◽  
S. Steeb

Xanes spectra of the amorphous Fe80B20- and Ni80B20-alloys have been investigated using the electron multiple scattering theory of Durham et al. The calculations were based on several models for the structure of amorphous Fe80B20 and Ni80B20. Very good agreement between theoretical and experimental XANES curves was met. Opposite to former expectations for obtaining information on bond angles by XANES, this study shows that XANES points to more complex features of the structure than can be expressed in terms of bond angles.


2008 ◽  
Vol 22 (29) ◽  
pp. 5155-5166 ◽  
Author(s):  
NGUYEN VAN HUNG ◽  
TONG SY TIEN ◽  
LE HAI HUNG ◽  
RONALD R. FRAHM

Anharmonic effective potential, Extended X-ray Absorption Fine Structure (EXAFS) and its parameters of hcp crystals have been theoretically and experimentally studied. Analytical expressions for the anharmonic effective potential, effective local force constant, three first cumulants, a novel anharmonic factor, thermal expansion coefficient and anhamonic contributions to EXAFS amplitude and phase have been derived. This anharmonic theory is applied to analyze the EXAFS of Zn and Cd at 77 K and 300 K, measured at HASYLAB (DESY, Germany). Numerical results are found to be in good agreement with experiment, where unnegligible anharmonic effects have been shown in the considered theoretical and experimental quantities.


Materials ◽  
2021 ◽  
Vol 14 (24) ◽  
pp. 7884
Author(s):  
Oleg O. Kartashov ◽  
Andrey V. Chernov ◽  
Dmitry S. Polyanichenko ◽  
Maria A. Butakova

Innovative development in the energy and chemical industries is mainly dependent on advances in the accelerated design and development of new functional materials. The success of research in new nanocatalysts mainly relies on modern techniques and approaches for their precise characterization. The existing methods of experimental characterization of nanocatalysts, which make it possible to assess the possibility of using these materials in specific chemical reactions or applications, generate significant amounts of heterogeneous data. The acceleration of new functional materials, including nanocatalysts, directly depends on the speed and quality of extracting hidden dependencies and knowledge from the obtained experimental data. Usually, such experiments involve different characterization techniques and different types of X-ray absorption spectroscopy (XAS) too. Using the machine learning (ML) methods based on XAS data, we can study and predict the atomic-scale structure and another bunch of parameters for the nanocatalyst efficiently. However, before using any ML model, it is necessary to make sure that the XAS raw experimental data is properly pre-processed, cleared, and prepared for ML application. Usually, the XAS preprocessing stage is vaguely presented in scientific studies, and the main efforts of researchers are devoted to the ML description and implementation stage. However, the quality of the input data influences the quality of ML analysis and the prediction results used in the future. This paper fills the gap between the stage of obtaining XAS data from synchrotron facilities and the stage of using and customizing various ML analysis and prediction models. We aimed this study to develop automated tools for the preprocessing and presentation of data from physical experiments and the creation of deposited datasets on the basis of the example of studying palladium-based nanocatalysts using synchrotron radiation facilities. During the study, methods of preliminary processing of XAS data were considered, which can be conditionally divided into X-ray absorption near edge structure (XANES) and extended X-ray absorption fine structure (EXAFS). This paper proposes a software toolkit that implements data preprocessing scenarios in the form of a single pipeline. The main preprocessing methods used in this study proposed are principal component analysis (PCA); z-score normalization; the interquartile method for eliminating outliers in the data; as well as the k-means machine learning method, which makes it possible to clarify the phase of the studied material sample by clustering feature vectors of experiments. Among the results of this study, one should also highlight the obtained deposited datasets of physical experiments on palladium-based nanocatalysts using synchrotron radiation. This will allow for further high-quality data mining to extract new knowledge about materials using artificial intelligence methods and machine learning models, and will ensure the smooth dissemination of these datasets to researchers and their reuse.


MRS Advances ◽  
2016 ◽  
Vol 1 (63-64) ◽  
pp. 4209-4214
Author(s):  
S.V. Stefanovsky ◽  
V.Y. Murzin ◽  
M.B. Remizov ◽  
B.F. Myasoedov

ABSTRACTIron and nickel oxidation state and coordination in complex sodium aluminophosphate based glasses suggested as potential matrices for immobilization of legacy high level waste currently stored in stainless steel tanks at PA «Mayak» (Ural reg., Russia) were determined by X-ray absorption fine structure spectroscopy (XAFS: XANES/EXAFS). The glasses containing (wt.%) 20-30 Na2O, 6-12 Al2O3, 40-52 P2O5, 2-5 Fe2O3, 1-3 NiO, 0-6 B2O3, 10-15 other waste oxides produced by quenching of their melts were fully amorphous or contained minor Fe and Ni free phases. Fe in the glasses was found to be predominantly trivalent with an average Fe-O distance and a coordination number (CN) in the first shell of 1.94 to 1.97 Å and 5.2 to 5.8, respectively, mostly in octahedral oxygen environment. Ni is divalent in all the glasses and has in the first shell an average Ni-O distance and CN of 1.97 to 2.03 Å and 4.9 to 5.6, respectively. The first shell of both Fe and Ni is somewhat distorted. The second and further coordination shells are weakly appeared exhibiting no clustering and homogeneous distribution of Fe and Ni ions in the glass network. The data on Fe obtained are in good agreement with those from Mössbauer study of same glasses. After annealing glasses were partly devitrified and interpretation of XAFS data is strongly complicated due to Fe and Ni partitioning among crystalline and vitreous phases.


Sign in / Sign up

Export Citation Format

Share Document