Three-Dimensional Reconstruction of Erythrocytes Using the Novel Method For Corrective Realignment of the Transmission Electron Microscopy Cross-Section Images

2018 ◽  
Vol 24 (6) ◽  
pp. 676-683
Author(s):  
Yuzhou Fan ◽  
Djordje Antonijević ◽  
Xing Zhong ◽  
Vladimir S. Komlev ◽  
Zhiyu Li ◽  
...  

AbstractThe detailed kinetics study of erythrocyte deformability is useful for the early diagnosis of blood diseases and for monitoring the blood rheology. Present solutions for a three-dimensional (3D) reconstruction of erythrocytes has a limited potential. This study aimed to use erythrocyte transmission electron images (ETIs) to evaluate the morphological relationship between adjacent ETIs and generate erythrocytes 3D model. First, ultrathin serial sections of skeletal muscle tissue were obtained using an ultramicrotome. Further, the set of ETIs in a capillary were captured by transmission electron microscopy. The images were aligned by translations and rotations using custom software to optimize the morphological relationship between adjacent ETIs. These coordinate transformations exploit the unique principal axis of inertia of each image to define the body coordinate system and hence provide the means to accurately reconnect the adjacent ETIs. The sum of the distances between the corresponding points on the boundary of adjacent ETIs was minimized and, further, was optimized by using physiological relationship between the adjacent ETIs. The analysis allowed to define precise virtual relationship between the adjacent erythrocytes. Finally, extracted erythrocytes’ cross-section images allowed to generate 3D model of the erythrocytes.

Author(s):  
W. D. Cooper ◽  
C. S. Hartley ◽  
J. J. Hren

Interpretation of electron microscope images of crystalline lattice defects can be greatly aided by computer simulation of theoretical contrast from continuum models of such defects in thin foils. Several computer programs exist at the present time, but none are sufficiently general to permit their use as an aid in the identification of the range of defect types encountered in electron microscopy. This paper presents progress in the development of a more general computer program for this purpose which eliminates a number of restrictions contained in other programs. In particular, the program permits a variety of foil geometries and defect types to be simulated.The conventional approximation of non-interacting columns is employed for evaluation of the two-beam dynamical scattering equations by a piecewise solution of the Howie-Whelan equations.


Author(s):  
D. L. Callahan ◽  
Z. Ball ◽  
H. M. Phillips ◽  
R. Sauerbrey

Ultraviolet laser-irradiation can be used to induce an insulator-to-conductor phase transition on the surface of Kapton polyimide. Such structures have potential applications as resistors or conductors for VLSI applications as well as general utility electrodes. Although the percolative nature of the phase transformation has been well-established, there has been little definitive work on the mechanism or extent of transformation. In particular, there has been considerable debate about whether or not the transition is primarily photothermal in nature, as we propose, or photochemical. In this study, cross-sectional optical microscopy and transmission electron microscopy are utilized to characterize the nature of microstructural changes associated with the laser-induced pyrolysis of polyimide.Laser-modified polyimide samples initially 12 μm thick were prepared in cross-section by standard ultramicrotomy. Resulting contraction in parallel to the film surface has led to distortions in apparent magnification. The scale bars shown are calibrated for the direction normal to the film surface only.


Author(s):  
L. D. Peachey ◽  
J. P. Heath ◽  
G. Lamprecht

Biological specimens of cells and tissues generally are considerably thicker than ideal for high resolution transmission electron microscopy. Actual image resolution achieved is limited by chromatic aberration in the image forming electron lenses combined with significant energy loss in the electron beam due to inelastic scattering in the specimen. Increased accelerating voltages (HVEM, IVEM) have been used to reduce the adverse effects of chromatic aberration by decreasing the electron scattering cross-section of the elements in the specimen and by increasing the incident electron energy.


2010 ◽  
Vol 16 (6) ◽  
pp. 662-669 ◽  
Author(s):  
S. Simões ◽  
F. Viana ◽  
A.S. Ramos ◽  
M.T. Vieira ◽  
M.F. Vieira

AbstractReactive multilayer thin films that undergo highly exothermic reactions are attractive choices for applications in ignition, propulsion, and joining systems. Ni/Al reactive multilayer thin films were deposited by dc magnetron sputtering with a period of 14 nm. The microstructure of the as-deposited and heat-treated Ni/Al multilayers was studied by transmission electron microscopy (TEM) and scanning transmission electron microscopy (STEM) in plan view and in cross section. The cross-section samples for TEM and STEM were prepared by focused ion beam lift-out technique. TEM analysis indicates that the as-deposited samples were composed of Ni and Al. High-resolution TEM images reveal the presence of NiAl in small localized regions. Microstructural characterization shows that heat treating at 450 and 700°C transforms the Ni/Al multilayered structure into equiaxed NiAl fine grains.


1990 ◽  
Vol 110 (4) ◽  
pp. 883-894 ◽  
Author(s):  
R Reichelt ◽  
A Holzenburg ◽  
E L Buhle ◽  
M Jarnik ◽  
A Engel ◽  
...  

Nuclear pore complexes (NPCs) prepared from Xenopus laevis oocyte nuclear envelopes were studied in "intact" form (i.e., unexposed to detergent) and after detergent treatment by a combination of conventional transmission electron microscopy (CTEM) and quantitative scanning transmission electron microscopy (STEM). In correlation-averaged CTEM pictures of negatively stained intact NPCs and of distinct NPC components (i.e., "rings," "spoke" complexes, and "plug-spoke" complexes), several fine structural features arranged with octagonal symmetry about a central axis could reproducibly be identified. STEM micrographs of unstained/freeze-dried intact NPCs as well as of their components yielded comparable but less distinct features. Mass determination by STEM revealed the following molecular masses: intact NPC with plug, 124 +/- 11 MD; intact NPC without plug, 112 +/- 11 MD; heavy ring, 32 +/- 5 MD; light ring, 21 +/- 4 MD; plug-spoke complex, 66 +/- 8 MD; and spoke complex, 52 +/- 3 MD. Based on these combined CTEM and STEM data, a three-dimensional model of the NPC exhibiting eightfold centrosymmetry about an axis perpendicular to the plane of the nuclear envelope but asymmetric along this axis is proposed. This structural polarity of the NPC across the nuclear envelope is in accord with its well-documented functional polarity facilitating mediated nucleocytoplasmic exchange of molecules and particles.


2008 ◽  
Vol 47 (1) ◽  
pp. 394-399 ◽  
Author(s):  
Hirotoshi Furusho ◽  
Yumiko Mishima ◽  
Norihiro Kameta ◽  
Mitsutoshi Masuda ◽  
Ichiro Yamashita ◽  
...  

2014 ◽  
Vol 47 (5) ◽  
pp. 1729-1735 ◽  
Author(s):  
Xin Nie ◽  
Yimin Guan ◽  
Dongshan Zhao ◽  
Yu Liu ◽  
Jianian Gui ◽  
...  

The crystallographic orientation relationships (ORs) of precipitated β-Mg2Sn particles in Mg–9.76 wt% Sn alloy aged at 573 K for 5 h, corresponding to its peak hardness, were investigated by advanced transmission electron microscopy (TEM). OR-3 of (110)β//(0001)αand [\overline 111]β//[1\overline 210]αand OR-4 of (110)β//(0001)αand [001]β//[2\overline 1\overline 10]αare the key ORs of β-Mg2Sn particles in the alloy. The proportions of β-Mg2Sn particles exhibiting OR-3 and OR-4 were determined as 75.1 and 24.3%, respectively. Crystallographic factors determined the predominance of OR-3 in the precipitated β-Mg2Sn particles. This mechanism was analyzed by a three-dimensional invariant line model constructed using a transformation matrix in reciprocal space. Models of the interface of precipitated β-Mg2Sn and the α-Mg matrix were constructedviahigh-resolution TEM and atomic resolution high-angle annular dark-field scanning TEM.


Sign in / Sign up

Export Citation Format

Share Document