Triggerable H2O2–Cleavable Switch of Paper-Based Biochips Endows Precision of Chemometer/Ratiometric Electrochemical Quantification of Analyte in High-Efficiency Point-of-Care Testing

2019 ◽  
Vol 91 (15) ◽  
pp. 10273-10281 ◽  
Author(s):  
Li Li ◽  
Yan Zhang ◽  
Shenguang Ge ◽  
Lina Zhang ◽  
Kang Cui ◽  
...  
Author(s):  
Tingyi Yan ◽  
Guangyao Zhang ◽  
Huining Chai ◽  
Lijun Qu ◽  
Xueji Zhang

With the outbreak and pandemic of COVID-19, point-of-care testing (POCT) systems have been attracted much attention due to their significant advantages of small batches of samples, user-friendliness, easy-to-use and simple detection. Among them, flexible biosensors show practical significance as their outstanding properties in terms of flexibility, portability, and high efficiency, which provide great convenience for users. To construct highly functional flexible biosensors, abundant kinds of polymers substrates have been modified with sufficient properties to address certain needs. Paper-based biosensors gain considerable attention as well, owing to their foldability, lightweight and adaptability. The other important flexible biosensor employs textiles as substrate materials, which has a promising prospect in the area of intelligent wearable devices. In this feature article, we performed a comprehensive review about the applications of flexible biosensors based on the classification of substrate materials (polymers, paper and textiles), and illustrated the strategies to design effective and artificial sensing platforms, including colorimetry, fluorescence, and electrochemistry. It is demonstrated that flexible biosensors play a prominent role in medical diagnosis, prognosis, and healthcare.


2019 ◽  
Vol 26 (11) ◽  
pp. 1946-1959 ◽  
Author(s):  
Le Minh Tu Phan ◽  
Lemma Teshome Tufa ◽  
Hwa-Jung Kim ◽  
Jaebeom Lee ◽  
Tae Jung Park

Background:Tuberculosis (TB), one of the leading causes of death worldwide, is difficult to diagnose based only on signs and symptoms. Methods for TB detection are continuously being researched to design novel effective clinical tools for the diagnosis of TB.Objective:This article reviews the methods to diagnose TB at the latent and active stages and to recognize prospective TB diagnostic methods based on nanomaterials.Methods:The current methods for TB diagnosis were reviewed by evaluating their advantages and disadvantages. Furthermore, the trends in TB detection using nanomaterials were discussed regarding their performance capacity for clinical diagnostic applications.Results:Current methods such as microscopy, culture, and tuberculin skin test are still being employed to diagnose TB, however, a highly sensitive point of care tool without false results is still needed. The utilization of nanomaterials to detect the specific TB biomarkers with high sensitivity and specificity can provide a possible strategy to rapidly diagnose TB. Although it is challenging for nanodiagnostic platforms to be assessed in clinical trials, active TB diagnosis using nanomaterials is highly expected to achieve clinical significance for regular application. In addition, aspects and future directions in developing the high-efficiency tools to diagnose active TB using advanced nanomaterials are expounded.Conclusion:This review suggests that nanomaterials have high potential as rapid, costeffective tools to enhance the diagnostic sensitivity and specificity for the accurate diagnosis, treatment, and prevention of TB. Hence, portable nanobiosensors can be alternative effective tests to be exploited globally after clinical trial execution.


2020 ◽  
Vol 27 ◽  
Author(s):  
Yi Zhang

: Point-of-care (POC) testing decentralizes the diagnostic tests to the sites near the patient. Many POC tests rely microfluidic platforms for sample-to-answer analysis. Compared to other microfluidic systems, magnetic digital microfluidics demonstrate compelling advantages for POC diagnostics. In this review, we have examined the capability of magnetic digital microfluidics-based POC diagnostic platforms. More importantly, we have categorized POC settings into three classes based on “where is the point”, “who to care” and “how to test”, and evaluated the suitability of magnetic digital microfluidics in various POC settings. Furthermore, we have addressed other technical issues associated with POC testing such as controlled environment, sample-system interface, system integration and information connectivity. We hope this review would provide a guideline for the future development of magnetic digital microfluidics-based platforms for POC testing.


Sign in / Sign up

Export Citation Format

Share Document