scholarly journals In Situ Cryogenic HAADF-STEM Observation of Spontaneous Transition of Ferroelectric Polarization Domain Structures at Low Temperatures

Nano Letters ◽  
2021 ◽  
Author(s):  
Junsik Mun ◽  
Wei Peng ◽  
Chang Jae Roh ◽  
Sangmin Lee ◽  
Syo Matsumura ◽  
...  
Author(s):  
F. H. Louchet ◽  
L. P. Kubin

Experiments have been carried out on the 3 MeV electron microscope in Toulouse. The low temperature straining holder has been previously described Images given by an image intensifier are recorded on magnetic tape.The microtensile niobium samples are cut in a plane with the two operative slip directions [111] and lying in the foil plane. The tensile axis is near [011].Our results concern:- The transition temperature of niobium near 220 K: at this temperature and below an increasing difference appears between the mobilities of the screw and edge portions of dislocations loops. Source operation and interactions between screw dislocations of different slip system have been recorded.


2002 ◽  
Vol 725 ◽  
Author(s):  
S.B. Phelan ◽  
B.S. O'Connell ◽  
G. Farrell ◽  
G. Chambers ◽  
H.J. Byrne

AbstractThe current voltage characteristics of C60 thin film sandwich structures fabricated by vacuum deposition on indium tin oxide (ITO) with an aluminium top electrode are presented and discussed. A strongly non-linear behavior and a sharp increase in the device conductivity was observed at relatively low voltages (∼2V), at both room and low temperatures (20K). At room temperature the system is seen to collapse, and in situ Raman measurements indicate a solid state reduction of the fullerene thin film to form a polymeric state. The high conductivity state was seen to be stable at elevated voltages and low temperatures. This state is seen to be reversible with the application of high voltages. At these high voltages the C60 film was seen to sporadically emit white light at randomly localized points analogous to the much documented Electroluminescence in single crystals.


Soft Matter ◽  
2019 ◽  
Vol 15 (4) ◽  
pp. 734-743 ◽  
Author(s):  
Pinzhang Chen ◽  
Jingyun Zhao ◽  
Yuanfei Lin ◽  
Jiarui Chang ◽  
Lingpu Meng ◽  
...  

The structural evolution of NR during stretching at −40 °C and in the strain–temperature space.


1988 ◽  
Vol 131 ◽  
Author(s):  
Thomas R. Omstead ◽  
Penny M. Van Sickle ◽  
Klavs F. Jensen

ABSTRACTThe growth of GaAs from triethylgallium (TEG) and trimethylgallium (TMG) with tertiarybutylarsine (tBAs), triethylarsenic (TEAs), and trimethylarsenic (TMAs), has been investigated by using a reactor equipped with a recording microbalance for in situ rate measurements. Rate data show that the growth with these precursors is dominated by the formation of adduct compounds in the gas lines, by adduct related parasitic gas phase reactions in the heated zone, and by the surface reactions. A model is proposed for the competition between deposition reactions and the parasitic gas phase reactions. Model predictions are in very good agreement with experimental data for all combinations of precursors except for TEG/TMAs where extensive gallium droplet formation is observed at low temperatures. Growth of reasonable quality GaAs with Hall mobilities of 7600 cm2/Vs at 77 K using TEG and tBAs is reported for the first time.


1989 ◽  
Vol 169 ◽  
Author(s):  
C. P. Burmester ◽  
L. T. Wille ◽  
R. Gronsky ◽  
B. T. Ahn ◽  
V. Y. Lee ◽  
...  

AbstractHigh resolution transmission electron microscopy during in‐situ quenching of YBa2Cu3Oz is used to study the kinetics of microdomain formation during oxygen loss in this system. Image simulations based on atomic models of oxygen‐vacancy order in the basal plane of this material generated by Monte Carlo calculations are used to interpret high resolution micrographs of the structures obtained by quenching. The observed domain structures agree well with those obtained from the simualtions.


2015 ◽  
Vol 25 (4) ◽  
pp. 386-394 ◽  
Author(s):  
Diego F. Escobar E. ◽  
Victor J. M. Cardoso

AbstractMiconia chartacea is a widely distributed tree in Brazil, occurring at altitudes ranging from 300 m to 1900 m in the Caatinga, Cerrado and Atlantic Forest biomes. In this work we attempted to classify M. chartacea seeds regarding their behaviour during storage and their germination syndrome and to determine, from a storage test in Cerrado soil and laboratory conditions in situ and ex situ, the longevity of seeds, as well as the capacity of the species to form a soil seed bank. The results suggested that M. chartacea seeds form a transient soil seed bank in the Cerrado and can be classified as orthodox in terms of storage behaviour, although the seeds are dispersed with a relatively high water content. The life span of seeds was favoured in soil-stored seeds in comparison with dry storage at 25°C, whereas storage at low temperatures prevented a decrease of the seed's germinability with storage time (330 d). M. chartacea seeds are dispersed during the dry season and germinate during the next rainy season, which can be classified as an intermediate–dry germination syndrome. Seeds of this species are dispersed in the Cerrado when temperatures and soil moisture are relatively low, which favours the formation of a soil seed bank, considering that the seeds tolerate desiccation and their longevity is favoured by low temperatures. A transient seed bank type is favoured by the loss of viability in storage at warm temperatures linked to the rainy season, and the predictable seasonal variations in climate in the region, with germination being restricted to the beginning of the rainy season.


2012 ◽  
Vol 5 (1) ◽  
pp. 1695-1715
Author(s):  
T. Foken ◽  
H. Falke

Abstract. A calibration instrument for krypton hygrometers (KH20, Campbell Sci.) with variable path length is presented. This unit allows for in-situ calibrations of the krypton hygrometer, which is typically not very stable over time, during measuring campaigns. It was constructed mainly for application at high altitudes and low temperatures, where further improvements are needed to the IR-hygrometers which are normally used. The changing path length requires that a changing concentration of the absorber be simulated. Because oxygen absorbs more strongly than water vapour, the calibration is made against oxygen and transferred to water vapour. The design of the calibration instrument is made as one unit containing a stepper motor system, PC and humidity sensor. For the calibration, it is necessary to install the krypton hygrometer on this unit.


2012 ◽  
Vol 8 ◽  
pp. 456-460 ◽  
Author(s):  
Toshiki Nokami ◽  
Akito Shibuya ◽  
Yoshihiro Saigusa ◽  
Shino Manabe ◽  
Yukishige Ito ◽  
...  

Glycosyl triflates with a 2,3-oxazolidinone protecting group were generated from thioglycosides by low-temperature electrochemical oxidation. The glycosyl triflates reacted with alcohols to give the corresponding glycosides β-selectively at low temperatures. However, α-selectivity was observed in the absence of base at elevated reaction temperatures. In situ generated triflic acid promotes the isomerization of β-products to α-products.


Sign in / Sign up

Export Citation Format

Share Document